Development of MEMS Airflow Volumetric Flow Sensing System with Single Piezoelectric Micromachined Ultrasonic Transducer (PMUT) Array
View through CrossRef
Compared to conventional ultrasonic flowmeters using multiple transducers, this paper reports, for the first time, an airflow volumetric flowmeter using a signal PMUT array to measure the flow rate in a rectangular pipe. The PMUT around 200 kHz is selected to fit the system requirements. All PMUT elements on this single array are then electrically grouped into transmitter and receiver. In order to minimize the crosstalk signal between transmitter and receiver, a phase shift signal is applied at the transmitter to reduce the amplitude of the crosstalk signal by 87.8%, hence, the resultant high sensing resolution. Based on the analog signal extracted from the single PMUT array, a complete flow sensing system is built by using the cross-correlation method and cosine interpolation, whereby the change in flow rate is reflected by the time of flight difference (dTof) recorded at the receiver. Meanwhile, the acoustic path self-calibration is realized by using multiple echoes. Compared with the previously reported MEMS flowmeters with dual or multiple PMUT devices, this paper proposes a single PMUT array flow sensing system, which is able to measure the flow rate changes up to 4 m3/h. With the implementation of a single device, the problem of ultrasound device/reflector misalignment during system setup is completely eradicated.
Title: Development of MEMS Airflow Volumetric Flow Sensing System with Single Piezoelectric Micromachined Ultrasonic Transducer (PMUT) Array
Description:
Compared to conventional ultrasonic flowmeters using multiple transducers, this paper reports, for the first time, an airflow volumetric flowmeter using a signal PMUT array to measure the flow rate in a rectangular pipe.
The PMUT around 200 kHz is selected to fit the system requirements.
All PMUT elements on this single array are then electrically grouped into transmitter and receiver.
In order to minimize the crosstalk signal between transmitter and receiver, a phase shift signal is applied at the transmitter to reduce the amplitude of the crosstalk signal by 87.
8%, hence, the resultant high sensing resolution.
Based on the analog signal extracted from the single PMUT array, a complete flow sensing system is built by using the cross-correlation method and cosine interpolation, whereby the change in flow rate is reflected by the time of flight difference (dTof) recorded at the receiver.
Meanwhile, the acoustic path self-calibration is realized by using multiple echoes.
Compared with the previously reported MEMS flowmeters with dual or multiple PMUT devices, this paper proposes a single PMUT array flow sensing system, which is able to measure the flow rate changes up to 4 m3/h.
With the implementation of a single device, the problem of ultrasound device/reflector misalignment during system setup is completely eradicated.
Related Results
AlScN Film Based Piezoelectric Micromechanical Ultrasonic Transducer for an Extended Long-Range Detection
AlScN Film Based Piezoelectric Micromechanical Ultrasonic Transducer for an Extended Long-Range Detection
Piezoelectric micromachined ultrasonic transducers (PMUTs) have been widely applied in distance sensing. However, the sensing distance of currently reported miniaturized ultrasonic...
(Invited) A 1-mG MEMS Sensor
(Invited) A 1-mG MEMS Sensor
MEMS (microelectromechanical systems) technology has contributed substantially to the miniaturization of inertial sensors, such as accelerometers and gyroscopes [1]. Nowadays, MEMS...
10 MHz Thin-Film PZT-Based Flexible PMUT Array: Finite Element Design and Characterization
10 MHz Thin-Film PZT-Based Flexible PMUT Array: Finite Element Design and Characterization
Piezoelectric micromachined ultrasound transducers (PMUT) incorporating lead zirconate titanate PbZr0.52Ti0.48O3 (PZT) thin films were investigated for miniaturized high-frequency ...
Review of high temperature piezoelectric materials, devices, and applications
Review of high temperature piezoelectric materials, devices, and applications
Piezoelectric functional materials have been extensively studied and employed in numerous devices. With the rapid development of modern industries, such as power plants, aerospace,...
Piezoelectric Micromachined Ultrasonic Transducer with a Dome-Shaped Single Layer Structure
Piezoelectric Micromachined Ultrasonic Transducer with a Dome-Shaped Single Layer Structure
Piezoelectric micromachined ultrasonic transducers (pMUTs) have been investigated as a promising new approach for ultrasound generation and reception. Most of the reported pMUTs em...
A Constitutive Model for Piezoelectric Paint with Mixed Connectivity
A Constitutive Model for Piezoelectric Paint with Mixed Connectivity
This article presents a constitutive model for piezoelectric paint that addresses its special characteristics such as mixed connectivity and air void content. Piezoelectric paint i...
Bimorph Dual-Electrode ScAlN PMUT with Two Terminal Connections
Bimorph Dual-Electrode ScAlN PMUT with Two Terminal Connections
This paper presents a novel bimorph Piezoelectric Micromachined Ultrasonic Transducer (PMUT) fabricated with 8-inch standard CMOS-compatible processes. The bimorph structure consis...
Surface and defect controlled high power piezoelectric ultrasonic transducers
Surface and defect controlled high power piezoelectric ultrasonic transducers
<sec>Researches have shown that a reasonably designed phononic crystal defect structure in high-power piezoelectric ultrasonic transducers can effectively suppress stray vibr...