A stable and secure supply of electrical energy to consumers is paramount and of primary importance. In the distribution system, disturbances often occur, especially during peak load times, which of course can result in a decrease in power, equipment damage, and power outages. This study aims to analyze the transient stability of the electric power distribution system, especially in PLN ULP North Manado, which focuses on one feeder, namely SR 8. By using ETAP 19.00 software, a Single Line Diagram simulation was carried out which includes 18 buses on the SL 8 feeder, especially the frequency and voltage response to disturbances on Bus 102. This simulation shows that after the load shedding, the system voltage condition reaches 150% of the nominal voltage, which states that the system is unstable (overhead) which causes significant changes in the voltage waveform and after that experiences damped oscillations and then returns to a stable condition. The results of the frequency show a linear decrease due to an increase in the system frequency, which is modeled through a linear equation as a form of system damping. From this study, it can be concluded that the distribution system in ULP North Manado experiences transient instability during load shedding, which is indicated by an excessive voltage response and a significant decrease in frequency. Therefore, a strategy is needed to improve system reliability, namely the implementation of Distributed Generation (DG), which can control system stability, particularly voltage and frequency, during disturbances.
ABSTRAKPasokan energi listrik yang stabil dan aman pada konsumen adalah hal terpenting dan yang utama. Pada sistem distribusi seringkali terjadi gangguan apalagi pada waktu beban puncak yang tentunya dapat mengakibatkan adanya penurunan daya, kerusakan peralatan, dan pemadaman listrik.Penelitian ini bertujuan untuk menganalisis stabilitas transien pada sistem distribusi tenaga listrik khususnya di PLN ULP Manado Utara, yang berfokuskan pada satu penyulang yaitu SR 8. Dengan menggunakan perankat lunak ETAP 19.00 maka dilakukan simulasi Single Line Diagram yang mencakup 18 bus pada penyulang SL 8 khususnya respon frekuensi dan tegangan terhadap gangguan pada Bus 102. Simulasi ini menunjukkan hasil bahwa setelah adanya pelepasan beban kondisi tegangan sistem mencapai 150% dari tegangan nominal yang menyatakan bahwa sistem tersebut tidak stabil (overhead) yang menyebabkan perubahan signifikan pada bentuk gelombang tegangan dan setelah itu mengalami osilasi teredam dan kemudian kembali dalam kondisi stabil. Hasil dari frekuensi menunjukkan adanya penurunan linier dikarenaan peningkatan pada frekuensi sistem,yang dimodelkan lewat persamaan linear sebagai bentuk redaman sistem. Dari penelitian ini bisa isimpulkan bahwa sistem distribusi di ULP Manado Utara terjadi ketidakstabilan transien pada saat adanya pelepasan beban, yang ditunjukkan oleh respon tegangan yang berlebih dan adanya penurunan frekuensi yang signifikan. Sehingga diperlukan strategi yang dapat meningkatkan keandalan sistem, yakni penerapan Distributed Generation (DG) yang bisa mengontrol kestabilan sistem khususnya tegangan dan frekuensi ketika terjadi gangguan.
Pusat Pengembangan Pendidikan dan Penelitian Indonesia
Title: ANALISIS STABILITAS GANGGUAN TRANSIENT PADA JARINGAN DISTRIBUSI DI WILAYAH ULP. MANADO UTARA
Description:
A stable and secure supply of electrical energy to consumers is paramount and of primary importance.
In the distribution system, disturbances often occur, especially during peak load times, which of course can result in a decrease in power, equipment damage, and power outages.
This study aims to analyze the transient stability of the electric power distribution system, especially in PLN ULP North Manado, which focuses on one feeder, namely SR 8.
By using ETAP 19.
00 software, a Single Line Diagram simulation was carried out which includes 18 buses on the SL 8 feeder, especially the frequency and voltage response to disturbances on Bus 102.
This simulation shows that after the load shedding, the system voltage condition reaches 150% of the nominal voltage, which states that the system is unstable (overhead) which causes significant changes in the voltage waveform and after that experiences damped oscillations and then returns to a stable condition.
The results of the frequency show a linear decrease due to an increase in the system frequency, which is modeled through a linear equation as a form of system damping.
From this study, it can be concluded that the distribution system in ULP North Manado experiences transient instability during load shedding, which is indicated by an excessive voltage response and a significant decrease in frequency.
Therefore, a strategy is needed to improve system reliability, namely the implementation of Distributed Generation (DG), which can control system stability, particularly voltage and frequency, during disturbances.
ABSTRAKPasokan energi listrik yang stabil dan aman pada konsumen adalah hal terpenting dan yang utama.
Pada sistem distribusi seringkali terjadi gangguan apalagi pada waktu beban puncak yang tentunya dapat mengakibatkan adanya penurunan daya, kerusakan peralatan, dan pemadaman listrik.
Penelitian ini bertujuan untuk menganalisis stabilitas transien pada sistem distribusi tenaga listrik khususnya di PLN ULP Manado Utara, yang berfokuskan pada satu penyulang yaitu SR 8.
Dengan menggunakan perankat lunak ETAP 19.
00 maka dilakukan simulasi Single Line Diagram yang mencakup 18 bus pada penyulang SL 8 khususnya respon frekuensi dan tegangan terhadap gangguan pada Bus 102.
Simulasi ini menunjukkan hasil bahwa setelah adanya pelepasan beban kondisi tegangan sistem mencapai 150% dari tegangan nominal yang menyatakan bahwa sistem tersebut tidak stabil (overhead) yang menyebabkan perubahan signifikan pada bentuk gelombang tegangan dan setelah itu mengalami osilasi teredam dan kemudian kembali dalam kondisi stabil.
Hasil dari frekuensi menunjukkan adanya penurunan linier dikarenaan peningkatan pada frekuensi sistem,yang dimodelkan lewat persamaan linear sebagai bentuk redaman sistem.
Dari penelitian ini bisa isimpulkan bahwa sistem distribusi di ULP Manado Utara terjadi ketidakstabilan transien pada saat adanya pelepasan beban, yang ditunjukkan oleh respon tegangan yang berlebih dan adanya penurunan frekuensi yang signifikan.
Sehingga diperlukan strategi yang dapat meningkatkan keandalan sistem, yakni penerapan Distributed Generation (DG) yang bisa mengontrol kestabilan sistem khususnya tegangan dan frekuensi ketika terjadi gangguan.
Related Results
DAMPAK TEKNOLOGI TERHADAP PROSES BELAJAR MENGAJAR
DAMPAK TEKNOLOGI TERHADAP PROSES BELAJAR MENGAJAR
DAFTAR PUSTAKAAditama, M. H. R., & Selfiardy, S. (2022). Kehidupan Mahasiswa Kuliah Sambil Bekerja di Masa Pandemi Covid-19. Kidspedia: Jurnal Pendidikan Anak Usia Dini, 3(...
ANALISA PENYEBAB GANGGUAN JARINGAN DISTRIBUSI GI SIRIMAU PT PLN. (PERSERO) AREA AMBON MENGGUNAKAN METODE FTA (FAULT TREE ANALISYS)
ANALISA PENYEBAB GANGGUAN JARINGAN DISTRIBUSI GI SIRIMAU PT PLN. (PERSERO) AREA AMBON MENGGUNAKAN METODE FTA (FAULT TREE ANALISYS)
Gangguan jaringan distribusi listrik Dapat di artikan bahwa adanya energi listrik yang hilang baik secara teknis maupun non teknis. Hal ini dapat di lihat berdasarkan data gangguan...
PROFIL GANGGUAN PENDENGARAN PADA PEMUSIK DI KOTA MANADO
PROFIL GANGGUAN PENDENGARAN PADA PEMUSIK DI KOTA MANADO
Abstract: Hearing loss due to noise (Noise Induced Hearing Loss - NIHL) is hearing impairment, either part or all, loss, irreversible, occur in one or both ears, can be mild, moder...
Analisis Kehandalan Sistem Konfigurasi Jaringan Penyulang 20 Kv di PT. PLN (Persero) ULP Pakam Kota Berbasis Matlab
Analisis Kehandalan Sistem Konfigurasi Jaringan Penyulang 20 Kv di PT. PLN (Persero) ULP Pakam Kota Berbasis Matlab
Penelitian ini bertujuan untuk mempelajari dan mengetahui sistem konfigurasi jaringan 20 kV di PT. PLN (Persero) ULP Pakam Kota yang memiliki total 15 sumber jaringan 20 kV (15 Pen...
Analisis Rugi Tegangan Jaringan Distribusi 20 KV Pada PT. PLN (Persero) Cabang Merauke
Analisis Rugi Tegangan Jaringan Distribusi 20 KV Pada PT. PLN (Persero) Cabang Merauke
Sistem Distribusi merupakan salah satu bagian penting dalam penyaluran energi listrik. Dalam penyalurannya, energi listrik yang disalurkan tidak seluruhnya diterima oleh konsumen. ...
Analisis Sistem Jaringan Tegangan Rendah di PT. PLN ULP Binjai Timur Dengan Metode Failure Mode and Effect
Analisis Sistem Jaringan Tegangan Rendah di PT. PLN ULP Binjai Timur Dengan Metode Failure Mode and Effect
Keandalan sistem jaringan tegangan rendah atau distribusi merupakan kemampuan sistem untuk memberikan suatu pasokan tenaga listrik yang cukup dengan kualitas memuaskan. Peningkatan...
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review Anna Tri Wahyuni1), Masfuri2), Liya Arista3)1,2,3 Fakultas Ilmu Keperawatan Univers...
Analisis Kinerja Fuse Cut Out Pada Sistem Distribusi 20KV Di PT. PLN (Persero) ULP Karangpilang
Analisis Kinerja Fuse Cut Out Pada Sistem Distribusi 20KV Di PT. PLN (Persero) ULP Karangpilang
Jaringan distribusi adalah sistem saluran atau jaringan yang menghubungkan antara sumber daya listrik utama dengan para konsumen listrik. Tujuan dari penelitian ini adalah untuk me...