Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A method for quantifying SPECT uniformity

View through CrossRef
Field uniformity is an important parameter for monitoring the performance of SPECT imaging systems. However, it is difficult to apply objective measures of uniformity because of the large variance associated with reconstructed images. In the proposed method, annular sampling of the SPECT uniformity image is used to reduce the noise level without decreasing the magnitude of uniformity artifacts. The reconstructed uniformity image is sectioned into annular rings centered on the center of rotation to match the expected distribution of uniformity artifacts. Statistical fluctuations are reduced by averaging the counts within the annular rings, allowing the use of objective measures of field uniformity such as integral uniformity. Application of the annular sampling technique on simulated and phantom uniformity images showed that the technique could reliably quantify SPECT uniformity artifacts at acceptable count levels. As a result this method can be used to objectively evaluate SPECT field uniformity in systems which utilize parallel collimation and circular orbits.
Title: A method for quantifying SPECT uniformity
Description:
Field uniformity is an important parameter for monitoring the performance of SPECT imaging systems.
However, it is difficult to apply objective measures of uniformity because of the large variance associated with reconstructed images.
In the proposed method, annular sampling of the SPECT uniformity image is used to reduce the noise level without decreasing the magnitude of uniformity artifacts.
The reconstructed uniformity image is sectioned into annular rings centered on the center of rotation to match the expected distribution of uniformity artifacts.
Statistical fluctuations are reduced by averaging the counts within the annular rings, allowing the use of objective measures of field uniformity such as integral uniformity.
Application of the annular sampling technique on simulated and phantom uniformity images showed that the technique could reliably quantify SPECT uniformity artifacts at acceptable count levels.
As a result this method can be used to objectively evaluate SPECT field uniformity in systems which utilize parallel collimation and circular orbits.

Related Results

Absolute quantification in brain SPECT imaging
Absolute quantification in brain SPECT imaging
Certes malalties neurològiques estan associades amb problemes en els sistemes de neurotransmissió. Una aproximació a l'estudi d'aquests sistemes és la tomografia d'emissió SPECT (S...
Evaluation of the sensitivity of SPECT/CT systems for 225Ac
Evaluation of the sensitivity of SPECT/CT systems for 225Ac
Radiopharmaceuticals labelled with alpha-emitting radionuclides, particularly 225Ac, are the most promising and interesting radiopharmaceuticals for the cancer treatment. Evaluatio...
Indeterminate solitary vertebral lesions on planar scintigraphy
Indeterminate solitary vertebral lesions on planar scintigraphy
Summary Objective: This study aims to evaluate the added value of hybrid SPECT-CT in differential diagnosis of indeterminate solitary vertebral lesion (SVL) on planar sci...
SU‐E‐I‐154: Cardiac SPECT/CT: Comparing Slow‐Rotation and Fast‐Rotation CT for Attenuation Correction in Cardiac Imaging
SU‐E‐I‐154: Cardiac SPECT/CT: Comparing Slow‐Rotation and Fast‐Rotation CT for Attenuation Correction in Cardiac Imaging
Purpose: The hybridisation of SPECT with X‐ray CT is expanding the utility of SPECT. In addition to image fusion, CT enables improved attenuation maps (AM) for SPECT. Two CT design...
Diagnostic Performance of Quantitative Ga-SPECT/CT for Patients with Lower-limb Osteomyelitis
Diagnostic Performance of Quantitative Ga-SPECT/CT for Patients with Lower-limb Osteomyelitis
Abstract Background Patients with lower-limb osteomyelitis (LLOM) may experience major adverse events, such as lower-leg amputations or death; therefore, early diagnosis a...
Resumo Distribuição dos Equipamentos PET-CT e SPECT em Minas Gerais Uma Análise da Disponibilidade e Acessibilidade pelo SUS.
Resumo Distribuição dos Equipamentos PET-CT e SPECT em Minas Gerais Uma Análise da Disponibilidade e Acessibilidade pelo SUS.
A Medicina Nuclear utiliza modalidades de diagnóstico por imagem que investigam aspectos funcionais e morfológicos do organismo. Entre as principais tecnologias, destacam-se a Tomo...
Radiation Dose Reduction Strategy for SPECT/CT Bone Scan
Radiation Dose Reduction Strategy for SPECT/CT Bone Scan
Abstract Purpose: The aim of this study is to introduce the optimization method of CT parameters to reduce patient radiation exposure in bone SPECT/CT while maintaining ima...

Back to Top