SU‐E‐I‐154: Cardiac SPECT/CT: Comparing Slow‐Rotation and Fast‐Rotation CT for Attenuation Correction in Cardiac Imaging
View through CrossRef
Purpose: The hybridisation of SPECT with X‐ray CT is expanding the utility of SPECT. In addition to image fusion, CT enables improved attenuation maps (AM) for SPECT. Two CT designs are used in SPECT/CT: slow‐ rotation and fast‐rotation. The “slow‐rotation” CT completes a full‐rotation in 15 seconds to provide an AM that is acquired over several frames of the respiratory cycle; hence includes motion related physiologic artifacts. The “fast‐rotation” CT completes a full‐rotation in 0.6 seconds to provide an AM that is comparatively free of breathing artifacts. Neither is similar to SPECT, which is acquired in a step‐and‐shoot manner, where each projection is acquired over all frames of the respiratory cycle. Methods: We compared cardiac SPECT/CT acquisitions with the General Electric Infinia/Hawkeye‐4 which incorporates a slow‐rotating CT and the Siemens Symbia/T6 which incorporates a fast‐rotating CT. Three canine experiments were performed comparing SPECT reconstructions that were corrected for attenuation with no respiratory motion between SPECT and CT (gold standard). These were compared with SPECT reconstructions that incorporated respiratory motion and corrected for attenuation using either the slow or fast‐CT AMs. The SPECT reconstructions were compared using a Root‐Mean‐Squared (RMS) metric and scatter plots, calculated pixel‐by‐ pixel in a region‐of‐interest through a central slice of the heart. Results: The canine experiments showed improvements in both the RMS error and correlation coefficients for all canines when using the fast‐CT AM. The average RMS error improved from 28% to 17%, while the average correlation coefficient improved from 0.85 to 0.96. Canine studies confirmed respiratory motion has the potential to corrupt CT data and can effect attenuation correction in SPECT. Conclusions: Artifacts in the attenuation map due to physiologic motion propagate into the SPECT image reconstructions causing erroneous results. Therefore, for SPECT to become more quantitative an attenuation map with fewer artifacts is desirable.
Title: SU‐E‐I‐154: Cardiac SPECT/CT: Comparing Slow‐Rotation and Fast‐Rotation CT for Attenuation Correction in Cardiac Imaging
Description:
Purpose: The hybridisation of SPECT with X‐ray CT is expanding the utility of SPECT.
In addition to image fusion, CT enables improved attenuation maps (AM) for SPECT.
Two CT designs are used in SPECT/CT: slow‐ rotation and fast‐rotation.
The “slow‐rotation” CT completes a full‐rotation in 15 seconds to provide an AM that is acquired over several frames of the respiratory cycle; hence includes motion related physiologic artifacts.
The “fast‐rotation” CT completes a full‐rotation in 0.
6 seconds to provide an AM that is comparatively free of breathing artifacts.
Neither is similar to SPECT, which is acquired in a step‐and‐shoot manner, where each projection is acquired over all frames of the respiratory cycle.
Methods: We compared cardiac SPECT/CT acquisitions with the General Electric Infinia/Hawkeye‐4 which incorporates a slow‐rotating CT and the Siemens Symbia/T6 which incorporates a fast‐rotating CT.
Three canine experiments were performed comparing SPECT reconstructions that were corrected for attenuation with no respiratory motion between SPECT and CT (gold standard).
These were compared with SPECT reconstructions that incorporated respiratory motion and corrected for attenuation using either the slow or fast‐CT AMs.
The SPECT reconstructions were compared using a Root‐Mean‐Squared (RMS) metric and scatter plots, calculated pixel‐by‐ pixel in a region‐of‐interest through a central slice of the heart.
Results: The canine experiments showed improvements in both the RMS error and correlation coefficients for all canines when using the fast‐CT AM.
The average RMS error improved from 28% to 17%, while the average correlation coefficient improved from 0.
85 to 0.
96.
Canine studies confirmed respiratory motion has the potential to corrupt CT data and can effect attenuation correction in SPECT.
Conclusions: Artifacts in the attenuation map due to physiologic motion propagate into the SPECT image reconstructions causing erroneous results.
Therefore, for SPECT to become more quantitative an attenuation map with fewer artifacts is desirable.
Related Results
Absolute quantification in brain SPECT imaging
Absolute quantification in brain SPECT imaging
Certes malalties neurològiques estan associades amb problemes en els sistemes de neurotransmissió. Una aproximació a l'estudi d'aquests sistemes és la tomografia d'emissió SPECT (S...
<b>Myocardial Perfusion Imaging: An Approach to Find Out When to Add SPECT/CT in MIBI Scan</b>
<b>Myocardial Perfusion Imaging: An Approach to Find Out When to Add SPECT/CT in MIBI Scan</b>
Background: Myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) is a key diagnostic tool for coronary artery disease (CAD), but its accuracy...
99mTc-DMSA renal cortical scanning: a comparison of planar, SPECT, and SPECT/CT imaging for the detection of renal cortical scarring
99mTc-DMSA renal cortical scanning: a comparison of planar, SPECT, and SPECT/CT imaging for the detection of renal cortical scarring
Abstract
Background
The best way to assess renal cortical scarring is planar scintigraphy with 99mTc-dimercaptosuccinic acid (DMSA), while the value...
Evaluation of the sensitivity of SPECT/CT systems for 225Ac
Evaluation of the sensitivity of SPECT/CT systems for 225Ac
Radiopharmaceuticals labelled with alpha-emitting radionuclides, particularly 225Ac, are the most promising and interesting radiopharmaceuticals for the cancer treatment. Evaluatio...
Diagnostic Performance of Quantitative Ga-SPECT/CT for Patients with Lower-limb Osteomyelitis
Diagnostic Performance of Quantitative Ga-SPECT/CT for Patients with Lower-limb Osteomyelitis
Abstract
Background
Patients with lower-limb osteomyelitis (LLOM) may experience major adverse events, such as lower-leg amputations or death; therefore, early diagnosis a...
Indeterminate solitary vertebral lesions on planar scintigraphy
Indeterminate solitary vertebral lesions on planar scintigraphy
Summary
Objective: This study aims to evaluate the added value of hybrid SPECT-CT in differential diagnosis of indeterminate solitary vertebral lesion (SVL) on planar sci...
Resumo Distribuição dos Equipamentos PET-CT e SPECT em Minas Gerais Uma Análise da Disponibilidade e Acessibilidade pelo SUS.
Resumo Distribuição dos Equipamentos PET-CT e SPECT em Minas Gerais Uma Análise da Disponibilidade e Acessibilidade pelo SUS.
A Medicina Nuclear utiliza modalidades de diagnóstico por imagem que investigam aspectos funcionais e morfológicos do organismo. Entre as principais tecnologias, destacam-se a Tomo...
Radiation Dose Reduction Strategy for SPECT/CT Bone Scan
Radiation Dose Reduction Strategy for SPECT/CT Bone Scan
Abstract
Purpose: The aim of this study is to introduce the optimization method of CT parameters to reduce patient radiation exposure in bone SPECT/CT while maintaining ima...