Javascript must be enabled to continue!
DETERMİNATİON OF PROTON PUMP İNHİBİTORS BY HİGH-PERFORMANCE LİQUİD CHROMATOGRAPHY
View through CrossRef
Aim of the work: Analysis of proton pump inhibitors by high-performance liquid chromatography.
Materials and methods. The studies were conducted on the following comparison standard samples and drugs. Standard samples: omeprazole (working standard Lot: B636472_01), pantoprazole (working standard: PANTBP/2023/01), dexlansoprazole (working standard: RLP/0890922). The following drugs were analyzed in the study: Omeprazole 20 mg capsule N30, Pantoprazole 20 mg tablet N28, Dexlansoprazole 30 mg capsule N30. Acetonitrile (Sigma-Aldrich series: I1306730339), triethylamine (Sigma-Aldrich series: S6010152947), 85% phosphoric acid (Merck KGaA, series: K52615773 029) and ultrapurified water were used as working solvents.
Results: The identity and quantity of the main active components included in the composition of omeprazole, pantoprazole and dexlansoprazole preparations were determined by the HPLC method. Optimal chromatographic conditions for the determination of the amount of HPLC in all three preparations were developed and prepared, and the wavelength of 285 nm, injection volume of 10 μl, temperature of 25°C, flow rate of 1.0 ml/min and “Purospher Star RP-8 endcapped” (4.6 x 150 mm, particle size 5 μm) column were determined to be optimal. The proposed method is distinguished by its accuracy, simplicity and short implementation time. The method allows for effective quality control of preparations during their production and use.
Title: DETERMİNATİON OF PROTON PUMP İNHİBİTORS BY HİGH-PERFORMANCE LİQUİD CHROMATOGRAPHY
Description:
Aim of the work: Analysis of proton pump inhibitors by high-performance liquid chromatography.
Materials and methods.
The studies were conducted on the following comparison standard samples and drugs.
Standard samples: omeprazole (working standard Lot: B636472_01), pantoprazole (working standard: PANTBP/2023/01), dexlansoprazole (working standard: RLP/0890922).
The following drugs were analyzed in the study: Omeprazole 20 mg capsule N30, Pantoprazole 20 mg tablet N28, Dexlansoprazole 30 mg capsule N30.
Acetonitrile (Sigma-Aldrich series: I1306730339), triethylamine (Sigma-Aldrich series: S6010152947), 85% phosphoric acid (Merck KGaA, series: K52615773 029) and ultrapurified water were used as working solvents.
Results: The identity and quantity of the main active components included in the composition of omeprazole, pantoprazole and dexlansoprazole preparations were determined by the HPLC method.
Optimal chromatographic conditions for the determination of the amount of HPLC in all three preparations were developed and prepared, and the wavelength of 285 nm, injection volume of 10 μl, temperature of 25°C, flow rate of 1.
0 ml/min and “Purospher Star RP-8 endcapped” (4.
6 x 150 mm, particle size 5 μm) column were determined to be optimal.
The proposed method is distinguished by its accuracy, simplicity and short implementation time.
The method allows for effective quality control of preparations during their production and use.
Related Results
MO‐SAM‐BRB‐02: Proton Physics and Technology
MO‐SAM‐BRB‐02: Proton Physics and Technology
The dose localization advantages of proton beams derive primarily from the Bragg peak in the proton stopping distribution. Therefore, the potential clinical gains expected form pro...
Impact of Proton Pump Inhibitors on Kidney Function and Chronic Kidney Disease Progression: A Systematic Review
Impact of Proton Pump Inhibitors on Kidney Function and Chronic Kidney Disease Progression: A Systematic Review
Abstract
Aim:
The aim of this systematic review is to comprehensively assess and analyze the impact of proton pump inhibitors on kidney function and their potential role i...
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Abstract
New results for downhole beam or rod pumps, from fairly recent test data are in conflict with traditional relationships. Additional testing is in progres...
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Abstract
New results for downhole beam or rod pumps from fairly recent test data are in conflict with traditional relationships. Additional testing is in progress...
Proton aurora related to intervals of pulsations of diminishing periods
Proton aurora related to intervals of pulsations of diminishing periods
Geomagnetic pulsations in the Pc1 frequency range are believed to be an indicator of electromagnetic ion cyclotron waves arriving from the equatorial magnetosphere, where the waves...
Therapeutic potential of SGLT-2 inhibitors and DDP4 inhibitors in elderly patients with type 2 diabetes mellitus and benign prostatic hyperplasia
Therapeutic potential of SGLT-2 inhibitors and DDP4 inhibitors in elderly patients with type 2 diabetes mellitus and benign prostatic hyperplasia
Background. Benign prostatic hyperplasia (BPH) has recently been linked to diabetes mellitus and insulin resistance. This study aims to explore whether the use of either sodium-glu...
Computer simulation of an excess proton in aqueous systems
Computer simulation of an excess proton in aqueous systems
This thesis aims at studying the microscopic physical-chemical properties of an excess proton in aqueous systems. From bulk water environments to narrow hydrophobic channels constr...
Pumping Unit Optimization
Pumping Unit Optimization
Abstract
In order to produce available fluids, pump jacks used at surface have been engineered to stroke as slow as 6 (six) strokes per minute (SPM) and as fast a...

