Javascript must be enabled to continue!
A Comprehensive Examination of Vector-Controlled Induction Motor Drive Techniques
View through CrossRef
This paper introduces a comprehensive examination of vector-controlled- (VC-) based techniques intended for induction motor (IM) drives. In addition, the evaluation and critique of modern control techniques that improve the performance of IM drives are discussed by considering a systematic literature survey. Detailed research on variable-speed drive control, for instance, VC and scalar control (SCC), was conducted. The SCC-based systems’ speed and V/f control purposes are clarified in closed and open loops of IM drives. The operations, benefits, and drawbacks of the direct and indirect field-oriented control systems are illustrated. Furthermore, the direct torque control (DTC) method for IMs is reviewed. Numerous VC methods established along with microprocessor/digital control, model reference adaptive control (MRAC), sliding mode control (SMC), and intelligent control (in terms of fuzzy logic (FL) and artificial neural networks (ANNs)) are described and examined. Uncertainties in the IM parameter are a considerable problem in VC drives. Therefore, this problem is addressed, and some studies that attempted to provide solutions are listed. Magnetic saturation and core loss impact are mentioned, as they are important issues in IM drives. Toward demonstrating the strengths and limitations of various VC configurations, a few experiments were simulated via MATLAB® and Simulink® that show the influence of machine parameter variation. Efforts are made to supply powerful guidelines for practicing engineers and researchers in AC drives.
Title: A Comprehensive Examination of Vector-Controlled Induction Motor Drive Techniques
Description:
This paper introduces a comprehensive examination of vector-controlled- (VC-) based techniques intended for induction motor (IM) drives.
In addition, the evaluation and critique of modern control techniques that improve the performance of IM drives are discussed by considering a systematic literature survey.
Detailed research on variable-speed drive control, for instance, VC and scalar control (SCC), was conducted.
The SCC-based systems’ speed and V/f control purposes are clarified in closed and open loops of IM drives.
The operations, benefits, and drawbacks of the direct and indirect field-oriented control systems are illustrated.
Furthermore, the direct torque control (DTC) method for IMs is reviewed.
Numerous VC methods established along with microprocessor/digital control, model reference adaptive control (MRAC), sliding mode control (SMC), and intelligent control (in terms of fuzzy logic (FL) and artificial neural networks (ANNs)) are described and examined.
Uncertainties in the IM parameter are a considerable problem in VC drives.
Therefore, this problem is addressed, and some studies that attempted to provide solutions are listed.
Magnetic saturation and core loss impact are mentioned, as they are important issues in IM drives.
Toward demonstrating the strengths and limitations of various VC configurations, a few experiments were simulated via MATLAB® and Simulink® that show the influence of machine parameter variation.
Efforts are made to supply powerful guidelines for practicing engineers and researchers in AC drives.
Related Results
Sliding Mode Controlled drives for wide speed operation of Threephase Induction Motor
Sliding Mode Controlled drives for wide speed operation of Threephase Induction Motor
Induction motor is widely used due to advantages in terms of performance, size, maintenance and efficiency compared to dc motor. Induction motor is either Scalar Controlled or Vect...
Outcomes Following Allogeneic Stem Cell Transplantation for AML in First Completion Remission Are Comparable between MRD Negative Patients and MRD Positive Patients Receiving Induction Only and Are Superior to MRD Positive Patients Receiving Induction and
Outcomes Following Allogeneic Stem Cell Transplantation for AML in First Completion Remission Are Comparable between MRD Negative Patients and MRD Positive Patients Receiving Induction Only and Are Superior to MRD Positive Patients Receiving Induction and
Background:
Data suggests that the presence of measurable residual disease (MRD) at the time of transplant for AML portends a poor prognosis. The timing of MRD asses...
Five-Phase Sensorless Induction Motor Drives With Lc Filter For High Power Applications
Five-Phase Sensorless Induction Motor Drives With Lc Filter For High Power Applications
Multi-phase IM drive systems are nowadays seen as a possible alternative to the three-phase drives due to their features that are especially suited for high power applications such...
Five-Phase Sensorless Induction Motor Drives With Lc Filter For High Power Applications
Five-Phase Sensorless Induction Motor Drives With Lc Filter For High Power Applications
Multi-phase IM drive systems are nowadays seen as a possible alternative to the three-phase drives due to their features that are especially suited for high power applications such...
Sistem Kontrol Torsi pada Motor DC
Sistem Kontrol Torsi pada Motor DC
AbstrakPenggunaan motor DC di dunia industri sangat penting. Kecepatan dan torsi motor DC sangat mempengaruhi kualitas dan kuantitas produk yang dihasilkan. Untuk itu, diperlukan s...
Performance Analysis of Brushless DC Motor Drive for Air Conditioner
Performance Analysis of Brushless DC Motor Drive for Air Conditioner
This paper presents an efficiency comparison and verification of two types of Brushless DC (BLDC) motors and drives combination. The trapezoidal BLDC motor is excited by trapezoida...
Perancangan Sistem Instrumentasi dan Kontrol Berbasis Super PLC F2424 serta Antarmuka Labview
Perancangan Sistem Instrumentasi dan Kontrol Berbasis Super PLC F2424 serta Antarmuka Labview
Abstract – PLC-based control is widely used in modern industry because it is able to work automatically controlling actuators for certain functions such as controlling thread rods ...
High Frequency Induction Motor Analysis for Common Mode and Differential Mode Impedance Characteristics
High Frequency Induction Motor Analysis for Common Mode and Differential Mode Impedance Characteristics
The parasitic currents issue arises at high frequency operation of induction motor. The flow of parasitic currents is the main cause of premature deterioration of winding insulatio...