Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Clinical outcomes of implantation of posterior chamber phakic intraocular lens for pathologic and non-pathologic myopia

View through CrossRef
Abstract Background To compare the clinical outcomes of posterior chamber phakic intraocular lens (pIOL) implantation for non-pathological myopia and pathological myopia. Methods This retrospective case series study which were conducted in Beijing Tongren Eye Center between July 2017 and Oct 2021 comprised 192 eyes of 100 consecutive patients undergoing pIOL implantation. Eyes were divided into two groups based on having pathological myopia or not. Predictability, efficacy, safety, and adverse events were compared at 6 months after pIOL implantation. Results Our study included 86 non-pathological myopes (171 eyes, group1) and 14 pathological myopes (21eyes, group2) to analysis. The average ages were 25.5 and 33.0, respectively, and the spherical equivalent (SE) were − 9.31D and − 17.50D pre-operation. Six months after pIOL implantation, the SE were 0.00 and − 0.50, respectively, and the refraction changes were statistically significant (P ≤ 0.05). Six months after surgery, 76.92% and 80.41% were within ± 0.50 D of the target and 92.31% and 95.88% were within ± 1.00 D. All eyes had unchanged BCVA or gained 1 or more lines in both groups and mean BCVA both improved a line 6m after operation. The efficacy index in the two groups were 0.95 and 0.88 and the safety index were 1.20, 1.33, respectively which was significantly different (P ≤ 0.05). Over the 6-month follow-up, no cataract, pigment dispersion glaucoma, pupillary block, or other vision-threatening complications happened, either. Conclusions The pIOL performed well for the correction of both non-pathological and pathological myopia throughout the 6-month observation period. The clinical outcomes of pIOL implantation for non-pathological myopia are essentially equivalent to those for pathological myopia.
Title: Clinical outcomes of implantation of posterior chamber phakic intraocular lens for pathologic and non-pathologic myopia
Description:
Abstract Background To compare the clinical outcomes of posterior chamber phakic intraocular lens (pIOL) implantation for non-pathological myopia and pathological myopia.
Methods This retrospective case series study which were conducted in Beijing Tongren Eye Center between July 2017 and Oct 2021 comprised 192 eyes of 100 consecutive patients undergoing pIOL implantation.
Eyes were divided into two groups based on having pathological myopia or not.
Predictability, efficacy, safety, and adverse events were compared at 6 months after pIOL implantation.
Results Our study included 86 non-pathological myopes (171 eyes, group1) and 14 pathological myopes (21eyes, group2) to analysis.
The average ages were 25.
5 and 33.
0, respectively, and the spherical equivalent (SE) were − 9.
31D and − 17.
50D pre-operation.
Six months after pIOL implantation, the SE were 0.
00 and − 0.
50, respectively, and the refraction changes were statistically significant (P ≤ 0.
05).
Six months after surgery, 76.
92% and 80.
41% were within ± 0.
50 D of the target and 92.
31% and 95.
88% were within ± 1.
00 D.
All eyes had unchanged BCVA or gained 1 or more lines in both groups and mean BCVA both improved a line 6m after operation.
The efficacy index in the two groups were 0.
95 and 0.
88 and the safety index were 1.
20, 1.
33, respectively which was significantly different (P ≤ 0.
05).
Over the 6-month follow-up, no cataract, pigment dispersion glaucoma, pupillary block, or other vision-threatening complications happened, either.
Conclusions The pIOL performed well for the correction of both non-pathological and pathological myopia throughout the 6-month observation period.
The clinical outcomes of pIOL implantation for non-pathological myopia are essentially equivalent to those for pathological myopia.

Related Results

Calculation of ocular magnification in phakic and pseudophakic eyes based on anterior segment OCT data
Calculation of ocular magnification in phakic and pseudophakic eyes based on anterior segment OCT data
AbstractPurposeThe purpose of this study is to develop a straightforward mathematical concept for determination of object to image magnification in both phakic and pseudophakic eye...
Myopia progression varies with age and severity of myopia
Myopia progression varies with age and severity of myopia
Objective To investigate annual myopia progression in individuals from South Indian states across different age groups, and its association with age of onset and severity of myopia...
Changes in Retinal Vascular Bifurcation in Eyes with Myopia
Changes in Retinal Vascular Bifurcation in Eyes with Myopia
Abstract Objective: To evaluate the effect of myopia on retinal vascular bifurcation. Methods: A cross-sectional study that retrospectively analyzed the fundus photographs ...
Myopia and Environmental Risk Factors: A Comprehensive Study
Myopia and Environmental Risk Factors: A Comprehensive Study
Background: The global rise in the prevalence of myopia calls for evidence-based strategies to be devised to reduce the incidence and delay the progression of Myopia. The aim is to...
A study on the status of myopia and pre-myopia among primary school students in different regions of Shaanxi Province, China
A study on the status of myopia and pre-myopia among primary school students in different regions of Shaanxi Province, China
ObjectiveThis cross-sectional study aimed to investigate the geographic disparities in myopia and pre-myopia prevalence among elementary school students across three distinct regio...
Public Awareness And Knowledge Of Factors Associated With Myopia In Kisumu County, Western Kenya
Public Awareness And Knowledge Of Factors Associated With Myopia In Kisumu County, Western Kenya
Abstract Background: Myopia is a global public health priority. Many modifiable and non modifiable risk factors have been shown to influence the development of myopia, but ...
Comparison of Patient's Satisfaction Level after Different Types of Posterior Chamber Intraocular Lens Implantation
Comparison of Patient's Satisfaction Level after Different Types of Posterior Chamber Intraocular Lens Implantation
Objective. To compare patient’s satisfaction level in performing routine activities during daylight and night vision after implantation with rigid, foldable, or rollable posterior ...

Back to Top