Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A Cost-Effective Dual-Element Metering System for Wet Gas Flowrate Measurement

View through CrossRef
Abstract A wet gas flowmeter based on field-proven flowmeters and flow computers has been developed. The flowmeter is engineered by integrating the well-established SmartCone meter, a Pitot tube meter and filed mounted Flow Computer technologies in one wet gas metering solution. This combination exploits the characteristics of these two flow metering elements in wet gas flowrate measurement; The Cone measurement in wet gas is characterized by its relatively large gas measurement over-read with increasing liquid-loading, whereas this has a significantly lower impact on the gas flowrate measured by the Pitot tube. The DynaCone wet gas flowmeter has been in development over the past several years with particular emphasis being placed on developing a flexible flowmeter for broad operating conditions and applications including high turndown ratio, minimal pressure loss, measurement quality diagnostic, and performance characterization in industry-recognized wet gas flow loop. The wet gas performance has been demonstrated at CEESI wet gas flow loop yielding gas flowrates better than ±3% in Type I wet gas range, and better than ±5% in Type II without the input of liquid flowrate to correct for over-reading. Furthermore, uncertainties better than 2% and 3% for Type I & II respectively can be achieved if periodic liquid flowrate information is available for input.
Title: A Cost-Effective Dual-Element Metering System for Wet Gas Flowrate Measurement
Description:
Abstract A wet gas flowmeter based on field-proven flowmeters and flow computers has been developed.
The flowmeter is engineered by integrating the well-established SmartCone meter, a Pitot tube meter and filed mounted Flow Computer technologies in one wet gas metering solution.
This combination exploits the characteristics of these two flow metering elements in wet gas flowrate measurement; The Cone measurement in wet gas is characterized by its relatively large gas measurement over-read with increasing liquid-loading, whereas this has a significantly lower impact on the gas flowrate measured by the Pitot tube.
The DynaCone wet gas flowmeter has been in development over the past several years with particular emphasis being placed on developing a flexible flowmeter for broad operating conditions and applications including high turndown ratio, minimal pressure loss, measurement quality diagnostic, and performance characterization in industry-recognized wet gas flow loop.
The wet gas performance has been demonstrated at CEESI wet gas flow loop yielding gas flowrates better than ±3% in Type I wet gas range, and better than ±5% in Type II without the input of liquid flowrate to correct for over-reading.
Furthermore, uncertainties better than 2% and 3% for Type I & II respectively can be achieved if periodic liquid flowrate information is available for input.

Related Results

A Downhole Constant Flow Nozzle Research in Waterflooding Wells
A Downhole Constant Flow Nozzle Research in Waterflooding Wells
Abstract Waterflooding has been proved one of the most effective IOR method for mature field. Commingle waterflooding may result in quick breakthrough. Zonal water i...
Evaluation of Dry-Gas Meters in Wet-Gas Conditions: Turbine and Venturi Meters
Evaluation of Dry-Gas Meters in Wet-Gas Conditions: Turbine and Venturi Meters
Abstract The accurate and reliable measurement of gas flowrate in wet gas conditions continues to be important to the Oil and Gas Industry. The ability to measure...
Wet Gas Metering: Trends in Applications and Technical Developments
Wet Gas Metering: Trends in Applications and Technical Developments
Abstract Wet gas metering covers a variety of measurements in production streams with high to very high gas volume fractions. There is a need for direct measurement ...
Design and simulation for seeding performance of high-speed inclined corn metering device based on discrete element method (DEM)
Design and simulation for seeding performance of high-speed inclined corn metering device based on discrete element method (DEM)
AbstractMechanical precision corn seed-metering planter has a compact structure, missed and repeated seeding advantages during high-speed operation. In this regard, the current res...
Large-Scale Application of Wet-Gas Metering at the Oman Upstream LNG Project
Large-Scale Application of Wet-Gas Metering at the Oman Upstream LNG Project
Abstract This paper describes the application of wet gas flow measurement to over 35 wells in the Oman Upstream LNG project. This multiphase metering process uses pe...
A technical and financial analysis of smart prepaid split meters on Eskom's electric power distribution
A technical and financial analysis of smart prepaid split meters on Eskom's electric power distribution
The implementation of a smart metering system in the distribution network does not only promote energy loss reduction, but also improves smart grids. This improvement in smart grid...
Zonal Test and Adjustment for Low Flowrate Waterflooding Wells
Zonal Test and Adjustment for Low Flowrate Waterflooding Wells
Abstract There are more and more layers with low water injection rate in waterflooding oilfields such as daqing periphery, jilin, jidong and etc. The typical layered...

Back to Top