Comparative Study of Biocompatible Titanium Alloys Containing Non-Toxic Elements for Orthopedic Implants

View through CrossRef
Titanium alloys, particularly Ti6Al4V, are commonly used in biomedical applications. However, the inclusion of aluminum (Al) and vanadium (V) in this alloy can cause cytotoxic effects in the human body, resulting in Alzheimer’s disease and cancer. This study compares the performance of biocompatible alloys containing non-toxic elements, such as tin (Sn) and niobium (Nb), which are considered safe for implantation. Two sets of alloys were selected, Ti5Sn and Ti5Sn5Nb, and their properties were compared to Ti6Al4V. First, the alloys were prepared using a power metallurgical technique. Then, their phase analysis, hardness, wear resistance, strength, and corrosion performance in simulated body fluid (SBF) solution were characterized. Optical microscopy was used to study the microstructure, XRD was used to identify phases, and electrochemical testing was conducted to assess the alloys’ anodic and cathodic characteristics. Nanoindentation techniques were used to analyze surface characteristics, such as elastic modulus, nano hardness, and wear resistance. The results showed the alloys containing Nb and Sn had lower corrosion rates in SBF solution compared to Al-containing alloys. Moreover, Nb-containing alloys exhibited the highest hardness, 72% higher than Al-containing alloys. The corrosion-resistant properties of the alloys containing Nb and Sn were higher than those without Nb or Sn, suggesting they may be ideal for orthopedic implants in humans.
Title: Comparative Study of Biocompatible Titanium Alloys Containing Non-Toxic Elements for Orthopedic Implants
Description:
Titanium alloys, particularly Ti6Al4V, are commonly used in biomedical applications.
However, the inclusion of aluminum (Al) and vanadium (V) in this alloy can cause cytotoxic effects in the human body, resulting in Alzheimer’s disease and cancer.
This study compares the performance of biocompatible alloys containing non-toxic elements, such as tin (Sn) and niobium (Nb), which are considered safe for implantation.
Two sets of alloys were selected, Ti5Sn and Ti5Sn5Nb, and their properties were compared to Ti6Al4V.
First, the alloys were prepared using a power metallurgical technique.
Then, their phase analysis, hardness, wear resistance, strength, and corrosion performance in simulated body fluid (SBF) solution were characterized.
Optical microscopy was used to study the microstructure, XRD was used to identify phases, and electrochemical testing was conducted to assess the alloys’ anodic and cathodic characteristics.
Nanoindentation techniques were used to analyze surface characteristics, such as elastic modulus, nano hardness, and wear resistance.
The results showed the alloys containing Nb and Sn had lower corrosion rates in SBF solution compared to Al-containing alloys.
Moreover, Nb-containing alloys exhibited the highest hardness, 72% higher than Al-containing alloys.
The corrosion-resistant properties of the alloys containing Nb and Sn were higher than those without Nb or Sn, suggesting they may be ideal for orthopedic implants in humans.

Related Results

Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Assessment of cranial reconstruction utilizing various implant materials: finite element study
Assessment of cranial reconstruction utilizing various implant materials: finite element study
AbstractThe human head can sometimes experience impact loads that result in skull fractures or other injuries, leading to the need for a craniectomy. Cranioplasty is a procedure th...
Comparative Cost-Effectiveness of Cranioplasty Implants
Comparative Cost-Effectiveness of Cranioplasty Implants
Purpose: The aim of this study was to compare operative duration and total hospital costs incurred for patients undergoing elective cranioplasty with a variety ...
Clinical outcomes of zirconia implants: a systematic review and meta-analysis
Clinical outcomes of zirconia implants: a systematic review and meta-analysis
Abstract Purpose To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. ...
Comparative Clinical Study of Conventional Dental Implants and Mini Dental Implants for Mandibular Overdentures: A Randomized Clinical Trial
Comparative Clinical Study of Conventional Dental Implants and Mini Dental Implants for Mandibular Overdentures: A Randomized Clinical Trial
AbstractBackgroundDental implant‐retained overdentures have been chosen as the treatment of choice for complete mandibular removable dentures. Dental implants, such as mini dental ...
15th World Conference on Titanium Chapter 2: Aerospace Applications
15th World Conference on Titanium Chapter 2: Aerospace Applications
RECENT ADVANCES IN TITANIUM ALLOY EXTRUSIONS FOR AEROSPACE APPLICATIONS TECHNOLOGY CAPABILITY STUDY OF LASER POWDER BED FUSION TO PRODUCE LARGE CRITICAL AEROSPACE S...
Copper Alloys
Copper Alloys
Abstract The article contains sections titled: ...