Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Biometry Measurements Using a New Large Coherence Length Swept-Source Optical Coherence Tomography

View through CrossRef
Abstract The swept-source OCT biometer (Argos) uses a 1060 nm wavelength and 20 nm bandwidth swept-source technology to collect 2-D OCT data of the full eye. The device measures the axial length and the anterior chamber depth, the central corneal thickness, aqueous depth, lens thickness, pupil size, the corneal diameter, and the corneal power in less than a second. The repeatability and reproducibility of the Argos measurements have been tested by means of variation analysis study and demonstrated that the new OCT biometer produces precise and reproducible measurements. Measurements made with the swept-source OCT biometer show a high acquisition rate compared with the IOLMaster 500 and the Lenstar biometers, especially in dense cataracts. The Argos swept-source optical coherence tomography measures the optical path length of each segment of the eye and uses a specific refractive index for each of these segments that has led to an improvement in IOL power calculation especially in long and short eyes.
Title: Biometry Measurements Using a New Large Coherence Length Swept-Source Optical Coherence Tomography
Description:
Abstract The swept-source OCT biometer (Argos) uses a 1060 nm wavelength and 20 nm bandwidth swept-source technology to collect 2-D OCT data of the full eye.
The device measures the axial length and the anterior chamber depth, the central corneal thickness, aqueous depth, lens thickness, pupil size, the corneal diameter, and the corneal power in less than a second.
The repeatability and reproducibility of the Argos measurements have been tested by means of variation analysis study and demonstrated that the new OCT biometer produces precise and reproducible measurements.
Measurements made with the swept-source OCT biometer show a high acquisition rate compared with the IOLMaster 500 and the Lenstar biometers, especially in dense cataracts.
The Argos swept-source optical coherence tomography measures the optical path length of each segment of the eye and uses a specific refractive index for each of these segments that has led to an improvement in IOL power calculation especially in long and short eyes.

Related Results

Interpretation of Simulated Falloff Tests
Interpretation of Simulated Falloff Tests
Abstract A study was made of the method for determination of swept volume and the proper average temperature to use for interpretation of combustion falloff data ...
Aerodynamic Characteristics of Forward Swept Wing in Subsonic Speed
Aerodynamic Characteristics of Forward Swept Wing in Subsonic Speed
A forward swept wing was designed to use for a supersonic aircraft. Its aerodynamic characteristics were studied through experiments and numerical simulations which excluded the su...
EN FACE IMAGING OF RETINAL ARTERY MACROANEURYSMS USING SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY
EN FACE IMAGING OF RETINAL ARTERY MACROANEURYSMS USING SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY
Purpose: To describe the advantages of en face view with swept-source optical coherence tomography in assessing the morphologic features of retinal arterial macroaneury...
Comparative Analysis of Refractive Outcomes Using Optical and Ultrasound Biometry in Phacoemulsification Cataract Surgery
Comparative Analysis of Refractive Outcomes Using Optical and Ultrasound Biometry in Phacoemulsification Cataract Surgery
Background: Accurate biometry is critical for optimal visual outcomes in cataract surgery. Both optical and ultrasound biometry are widely used, but their comparative effectiveness...
STARDUST SIGN AND RETINAL TEAR DETECTION ON SWEPT SOURCE OPTICAL COHERENCE TOMOGRAPHY
STARDUST SIGN AND RETINAL TEAR DETECTION ON SWEPT SOURCE OPTICAL COHERENCE TOMOGRAPHY
Purpose: The causes of floaters include posterior vitreous detachment and fundus hemorrhage, both of which are risk factors for retinal tears. We observed the vitreous ...
OPTICAL COHERENCE TOMOGRAPHY-ANGIOGRAPHY, A NEW DIAGNOSTIC AND FOLLOW-UP TOOL FOR GLAUCOMA
OPTICAL COHERENCE TOMOGRAPHY-ANGIOGRAPHY, A NEW DIAGNOSTIC AND FOLLOW-UP TOOL FOR GLAUCOMA
Glaucoma is an optic neuropathy and is one of the leading causes of irreversible blindness worldwide. There are studies on the role of vascular dysfunction in the pathogenesis of g...

Back to Top