Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparison of Ultrasound Biometry with Optical Biometry for Measurement of Axial Length and Calculation of Intraocular Lens Power in Patients Undergoing Routine Cataract Surgery

View through CrossRef
Objective: To compare the axial length and intraocular lens power calculated by using ultrasound biometry and optical biometry in patients with cataract Methodology: It was prospective randomized control trial carried out at eye department of Pakistan Institute of Medical Sciences Islamabad from Oct 2021-December 2021, comprising of 50 patients undergoing contract surgery in Eye Department of PIMS using non-probability consecutive sampling. After taking informed written consent from patient’s biometry was performed using optical scan and ultrasound biometry (with appalation probe). Axial length and intraocular power calculated by both methods was recorded. Results: The mean axial length measurement by ultrasound of the patients’ eyes was 22.72±0.85 mm and by optical biometry was 22.67±0.86 mm. Similarly the mean intraocular lens power calculated by ultrasound was 20.60±1.56D and by optical was 20.51±1.51D. Optical and ultrasound method showed strong positive correlation in measurements of intraocular lens power and axial length of eyes, i.e. r=0.965 & 0.939 respectively. Conclusion: The findings of this study suggested that optical biometry is good alternate of ultrasound in measurement of axial length and intraocular lens power of patients, as strong correlation exist between both techniques
Title: Comparison of Ultrasound Biometry with Optical Biometry for Measurement of Axial Length and Calculation of Intraocular Lens Power in Patients Undergoing Routine Cataract Surgery
Description:
Objective: To compare the axial length and intraocular lens power calculated by using ultrasound biometry and optical biometry in patients with cataract Methodology: It was prospective randomized control trial carried out at eye department of Pakistan Institute of Medical Sciences Islamabad from Oct 2021-December 2021, comprising of 50 patients undergoing contract surgery in Eye Department of PIMS using non-probability consecutive sampling.
After taking informed written consent from patient’s biometry was performed using optical scan and ultrasound biometry (with appalation probe).
Axial length and intraocular power calculated by both methods was recorded.
Results: The mean axial length measurement by ultrasound of the patients’ eyes was 22.
72±0.
85 mm and by optical biometry was 22.
67±0.
86 mm.
Similarly the mean intraocular lens power calculated by ultrasound was 20.
60±1.
56D and by optical was 20.
51±1.
51D.
Optical and ultrasound method showed strong positive correlation in measurements of intraocular lens power and axial length of eyes, i.
e.
r=0.
965 & 0.
939 respectively.
Conclusion: The findings of this study suggested that optical biometry is good alternate of ultrasound in measurement of axial length and intraocular lens power of patients, as strong correlation exist between both techniques.

Related Results

Evaluation of different techniques of measurement of the axial length in silicone oil-filled eyes
Evaluation of different techniques of measurement of the axial length in silicone oil-filled eyes
Purpose To evaluate different techniques of axial length measurement in silicone oil-filled eyes and compare the results of each with the original axial length ...
Eyes of Aniso-Axial Length Individuals Share Generally Similar Corneal Biometrics with Normal Eyes in Cataract Population
Eyes of Aniso-Axial Length Individuals Share Generally Similar Corneal Biometrics with Normal Eyes in Cataract Population
Aims. To determine the characteristics of corneal biometrics in eyes from aniso-axial length cataract patients compared with eyes from non-aniso-axial length individuals. Methods. ...
“Prevalence And Determinants Of Age-Related Cataract In The Rural Population: A Cross-Sectional Study”
“Prevalence And Determinants Of Age-Related Cataract In The Rural Population: A Cross-Sectional Study”
Background of the Study: Age-related cataract is the leading cause of preventable blindness and visual impairment worldwide, particularly among elderly populations in low- and midd...
The impact of cataract surgery on tear film physiology: signs and symptoms, progression and treatment
The impact of cataract surgery on tear film physiology: signs and symptoms, progression and treatment
PurposeThis study aimed to revise data published in the literature on the effects of cataract surgery on tear film characteristics, in relation to personal clinical surgical experi...
Comparative Analysis of Refractive Outcomes Using Optical and Ultrasound Biometry in Phacoemulsification Cataract Surgery
Comparative Analysis of Refractive Outcomes Using Optical and Ultrasound Biometry in Phacoemulsification Cataract Surgery
Background: Accurate biometry is critical for optimal visual outcomes in cataract surgery. Both optical and ultrasound biometry are widely used, but their comparative effectiveness...
Difficulties of Cataract Surgery in Lens-Induced Glaucoma Due to Subluxated Cataract
Difficulties of Cataract Surgery in Lens-Induced Glaucoma Due to Subluxated Cataract
Introduction: Cataract is a disease of the eye in which the normal clear lens has opacified and obscured the passage of light. A mature cataract occurs when the lens is opacified. ...
Phacoemulsification in trabeculectomized eyes
Phacoemulsification in trabeculectomized eyes
Abstract.Purpose:  To evaluate retrospectively risk indicators for cataract surgery and the effect of phacoemulsification on intraocular pressure (IOP) control in eyes that have u...

Back to Top