Javascript must be enabled to continue!
Variantes angio-tomodensitométriques de l’aorte abdominale chez le sujet adulte au Togo
View through CrossRef
Objective: To describe the morphology and biometrics of the abdominal aorta using computed tomography in adult togolese individuals.
Materials and Methods: This descriptive cross-sectional survey was conducted with prospective data collection between May 5th and July 4th, 2024, across computed tomography units in two hospitals located in Lomé and one in Kara, Togo. Data of patients who underwent contrast-enhanced abdominopelvic CT scans with an arterial phase were retrieved from the PACS (Picture Archiving and Communication System). For each participant, the level of the aortic hiatus, site of bifurcation of the aorta into the iliac arteries, type of aortic trajectory, and diameters of the aorta above and below the renal arteries were documented.
Results: Among the 124 patients included in the analysis, 71 (57.3%) were female, yielding a male-to-female ratio of 0.74. The average age of the participants was 51.7 ± 16.3 years, and the median age was 55.5 years (interquartile range = 25). The aortic diaphragmatic hiatus was identified at the level of the twelfth thoracic vertebra (T12) in 55.6% of subjects. The aortoiliac bifurcation was situated at the level of the fourth lumbar vertebra in 78.2% of participants. A linear course of the aorta was observed in 66.1% of cases, whereas a non-linear trajectory was noted in 33.9%. The incidence of non-linear aortic trajectory was five-fold higher among individuals aged over 56 years than among those aged 56 years or younger (p = 0.001). The mean diameter of the abdominal aorta was 20.9 ± 3 mm above the renal arteries and 15.8 ± 2.2 mm below them. The diameters of the aorta above and below the renal arteries were found to be significantly larger in males than in females, as well as in individuals over the age of 56 compared to those aged 56 or younger (p < 0.001). No significant differences were observed regarding sex in relation to the aortic trajectory, height of the aortic hiatus, or level of aortic bifurcation.
Conclusion: The non-linear trajectory of the abdominal aorta is more frequent in individuals over 56 years old, and its caliber is significantly greater in men compared to women.
Résumé
Objectif : Décrire à la tomodensitométrie la morphologie et la biométrie de l’aorte abdominale chez le sujet adulte togolais.
Matériels et méthodes : Étude transversale descriptive avec collecte prospective de données entre le 05 mai et le 04 juillet 2024 au sein de l'unité de scanner de trois établissements hospitaliers dont deux à Lomé et un à Kara, Togo. Les données des patients ayant réalisé un examen tomodensitométrique de la région abdomino-pelvienne avec injection de produit de contraste au temps artériel ont été recueillies sur le PACS. La hauteur du hiatus aortique, de la bifurcation aorto-iliaque, le type de trajet et le calibre de l’aorte abdominale sus et sous rénale ont été déterminés chez chaque participant.
Résultats : Parmi les 124 patients inclus dans l’étude, 71 (57,3%) étaient des femmes (sex-ratio=0,74). L’âge moyen des participants était de 51,7 ± 16,3 ans et l’âge médian de 55,5 (intervalle interquartile=25) ans. Le hiatus diaphragmatique de l’aorte était localisé à hauteur de la douzième vertèbre thoracique chez 55,6% des participants. La bifurcation aorto-iliaque était située à hauteur de la quatrième vertèbre lombaire chez 78,2% des participants. Le trajet de l’aorte était rectiligne chez 66,1% des participants et ne l’était pas dans 33,9% des cas. Le trajet non rectiligne de l’aorte était cinq fois plus fréquent chez les sujets de plus de 56 ans par rapport à ceux âgés de moins de 56 ans (p=0,001). Le calibre moyen de l’aorte abdominale sus-rénale était de 20,9 ± 3 mm et celui de l’aorte sous-rénale était de 15,8 ± 2,2 mm. Le calibre de l'aorte sus et sous-rénale était significativement plus important chez les hommes (p < 0,001). De même, le calibre de l’aorte des sujets de plus de 56 ans était plus important comparativement à ceux âgés de 56 ans ou moins (p < 0,001). Le sexe n’avait pas d’influence sur le trajet de l’aorte, la hauteur du hiatus diaphragmatique et la bifurcation aorto-iliaque.
Conclusion :Le trajet non rectiligne de l’aorte abdominale est plus fréquent chez les personnes âgées de plus de 56 ans et son calibre est plus important chez les hommes comparativement aux femmes.
Societe de Radiologie d'Afrique Noire Francophone
Title: Variantes angio-tomodensitométriques de l’aorte abdominale chez le sujet adulte au Togo
Description:
Objective: To describe the morphology and biometrics of the abdominal aorta using computed tomography in adult togolese individuals.
Materials and Methods: This descriptive cross-sectional survey was conducted with prospective data collection between May 5th and July 4th, 2024, across computed tomography units in two hospitals located in Lomé and one in Kara, Togo.
Data of patients who underwent contrast-enhanced abdominopelvic CT scans with an arterial phase were retrieved from the PACS (Picture Archiving and Communication System).
For each participant, the level of the aortic hiatus, site of bifurcation of the aorta into the iliac arteries, type of aortic trajectory, and diameters of the aorta above and below the renal arteries were documented.
Results: Among the 124 patients included in the analysis, 71 (57.
3%) were female, yielding a male-to-female ratio of 0.
74.
The average age of the participants was 51.
7 ± 16.
3 years, and the median age was 55.
5 years (interquartile range = 25).
The aortic diaphragmatic hiatus was identified at the level of the twelfth thoracic vertebra (T12) in 55.
6% of subjects.
The aortoiliac bifurcation was situated at the level of the fourth lumbar vertebra in 78.
2% of participants.
A linear course of the aorta was observed in 66.
1% of cases, whereas a non-linear trajectory was noted in 33.
9%.
The incidence of non-linear aortic trajectory was five-fold higher among individuals aged over 56 years than among those aged 56 years or younger (p = 0.
001).
The mean diameter of the abdominal aorta was 20.
9 ± 3 mm above the renal arteries and 15.
8 ± 2.
2 mm below them.
The diameters of the aorta above and below the renal arteries were found to be significantly larger in males than in females, as well as in individuals over the age of 56 compared to those aged 56 or younger (p < 0.
001).
No significant differences were observed regarding sex in relation to the aortic trajectory, height of the aortic hiatus, or level of aortic bifurcation.
Conclusion: The non-linear trajectory of the abdominal aorta is more frequent in individuals over 56 years old, and its caliber is significantly greater in men compared to women.
Résumé
Objectif : Décrire à la tomodensitométrie la morphologie et la biométrie de l’aorte abdominale chez le sujet adulte togolais.
Matériels et méthodes : Étude transversale descriptive avec collecte prospective de données entre le 05 mai et le 04 juillet 2024 au sein de l'unité de scanner de trois établissements hospitaliers dont deux à Lomé et un à Kara, Togo.
Les données des patients ayant réalisé un examen tomodensitométrique de la région abdomino-pelvienne avec injection de produit de contraste au temps artériel ont été recueillies sur le PACS.
La hauteur du hiatus aortique, de la bifurcation aorto-iliaque, le type de trajet et le calibre de l’aorte abdominale sus et sous rénale ont été déterminés chez chaque participant.
Résultats : Parmi les 124 patients inclus dans l’étude, 71 (57,3%) étaient des femmes (sex-ratio=0,74).
L’âge moyen des participants était de 51,7 ± 16,3 ans et l’âge médian de 55,5 (intervalle interquartile=25) ans.
Le hiatus diaphragmatique de l’aorte était localisé à hauteur de la douzième vertèbre thoracique chez 55,6% des participants.
La bifurcation aorto-iliaque était située à hauteur de la quatrième vertèbre lombaire chez 78,2% des participants.
Le trajet de l’aorte était rectiligne chez 66,1% des participants et ne l’était pas dans 33,9% des cas.
Le trajet non rectiligne de l’aorte était cinq fois plus fréquent chez les sujets de plus de 56 ans par rapport à ceux âgés de moins de 56 ans (p=0,001).
Le calibre moyen de l’aorte abdominale sus-rénale était de 20,9 ± 3 mm et celui de l’aorte sous-rénale était de 15,8 ± 2,2 mm.
Le calibre de l'aorte sus et sous-rénale était significativement plus important chez les hommes (p < 0,001).
De même, le calibre de l’aorte des sujets de plus de 56 ans était plus important comparativement à ceux âgés de 56 ans ou moins (p < 0,001).
Le sexe n’avait pas d’influence sur le trajet de l’aorte, la hauteur du hiatus diaphragmatique et la bifurcation aorto-iliaque.
Conclusion :Le trajet non rectiligne de l’aorte abdominale est plus fréquent chez les personnes âgées de plus de 56 ans et son calibre est plus important chez les hommes comparativement aux femmes.
Related Results
Résumés des conférences JRANF 2021
Résumés des conférences JRANF 2021
able des matières
Résumés. 140
Agenda Formation en Radioprotection JRANF 2021 Ouagadougou. 140
RPF 1 Rappel des unités de doses. 140
RPF 2 Risques déterministes et stochastique...
Exploration et modulation du récepteur TREM-1 dans le développement de l'anévrisme de l'aorte abdominale expérimental
Exploration et modulation du récepteur TREM-1 dans le développement de l'anévrisme de l'aorte abdominale expérimental
L'anévrisme de l'aorte abdominale (AAA) représente une des principales causes de décès cardiovasculaires à travers le monde, principalement parmi les hommes de plus de 65 ans. L'AA...
Hebbian and Homeostatic plasticity in the adult visual cortex
Hebbian and Homeostatic plasticity in the adult visual cortex
Plasticité Hebbienne et Homeostatique dans le cortex visuel de l’adulte
Cette thèse explore comment la plasticité hebbienne et homéostatique coexistent dans le syst...
Modélisation de la compliance de l'aorte dans le cas de pathologies de type anévrisme
Modélisation de la compliance de l'aorte dans le cas de pathologies de type anévrisme
L’Anévrisme de l’Aorte Abdominale (AAA) est une pathologie qui est définie par une dilatation localisée et permanente de l’artère et qui concerne plus de 8.8% des personnes âgées. ...
Le conditionnement hypoxique, nouvelle stratégie thérapeutique dans les maladies chroniques
Le conditionnement hypoxique, nouvelle stratégie thérapeutique dans les maladies chroniques
Si l’hypoxie semble avoir des côtés bénéfiques, elle peut aussi être responsable de nombreux effets délétères pour notre organisme en générant par exemple des anomalies vasculaires...
Évaluation dosimétrique des scanopelvimétries au Togo.
Évaluation dosimétrique des scanopelvimétries au Togo.
Objective : To assess the X-ray doses delivered to pregnant women during pelvimetry by CT scan in Togo.
Materials and methods : Cross-sectional study carried out from 6 March to 3...
Cinétique d'expression hypothalamique des microARN chez le rat : impact d'un régime maternel hyperlipidique
Cinétique d'expression hypothalamique des microARN chez le rat : impact d'un régime maternel hyperlipidique
Le concept de programmation métabolique repose sur les études épidémiologiques pionnières menées par David Barker à la fin des années 1980 : une sous-nutrition maternelle durant la...
Rôle des plaquettes dans la formation du thrombus intraluminal de l'anévrisme de l'aorte abdominale
Rôle des plaquettes dans la formation du thrombus intraluminal de l'anévrisme de l'aorte abdominale
L'anévrisme de l'aorte abdominale (AAA) est une pathologie caractérisée par une dilatation du diamètre de 50% supérieure par rapport à son diamètre initial. L'anévrisme présente so...

