Large Scale PWR Passive Containment Cooling System Wind Tunnel Test

View through CrossRef
CAP1400 is a large passive pressurized water reactor nuclear power plant, which relies on engineering safety features such as passive containment cooling system (PCS) to remove the decay heat in the containment and mitigate accident consequences. PCS is designed to perform passive containment cooling which is mainly dependent on natural convection inside the containment and inner wall condensation heat transfer, outer containment surface water film coverage and evaporation heat transfer and external air flow path cooling performance, etc. Among them, the key factors that affect the performance of the external air flow path include the flow resistance characteristics of the air flow path and the wind-direction neutrality characteristics. The relevant performance will be the important design input of the accident analysis, which will directly affect the safety of the power plant. During the normal operation of power plant, the PCS air flow path is influenced by the external environment, and its internal flow is very complicated. Designers are often lack of data support, and can’t fully consider the impact of environmental flow. In order to fully study the performance of PCS air flow path, it is necessary to perform PCS integrated scaled wind tunnel test. According to the original design of CAP1400 PCS system, the model scale research is developed and CAP1400 PCS wind tunnel test scaled model is established and the scale is 1:100. The test model includes shield building model and the surrounding plant model, which contain pressure measuring points uniformly distributed in 6 horizontal cross sections of the shield building. The pressure measuring point arrangement does not affect air flow in the air flow path. The following wind tunnel tests are simulated in different wind speed including 15m/s, 20m/s, 10m/s, 25m/s. The air flow pressure, wind velocity at the inlet and outlet of air flow path and the pressure distribution of inner annulus and outer annulus are measured in order to study the air flow pressure drop and wind-direction neutrality characteristics, and the wind tunnel test also considers the different wind direction angle, with and without the surrounding buildings and the effects of different landforms. The test results show that the flow rate of inlet and outlet of air flow path is balanced and the wind velocity at the upwind and central area of the flow path outlet is larger than other area, and a large vortex comes on the leeward side near the wall. The local uneven flow phenomenon exists in the outer annulus of the air flow path, but the wind pressure distribution of inner annulus is not affected by environment wind speed, wind direction angle, landforms and the surrounding buildings. So CAP1400 PCS air flow path has the characteristics of wind direction neutrality, and the natural convection of the air flow path will not be adversely affected by the environment wind.
Title: Large Scale PWR Passive Containment Cooling System Wind Tunnel Test
Description:
CAP1400 is a large passive pressurized water reactor nuclear power plant, which relies on engineering safety features such as passive containment cooling system (PCS) to remove the decay heat in the containment and mitigate accident consequences.
PCS is designed to perform passive containment cooling which is mainly dependent on natural convection inside the containment and inner wall condensation heat transfer, outer containment surface water film coverage and evaporation heat transfer and external air flow path cooling performance, etc.
Among them, the key factors that affect the performance of the external air flow path include the flow resistance characteristics of the air flow path and the wind-direction neutrality characteristics.
The relevant performance will be the important design input of the accident analysis, which will directly affect the safety of the power plant.
During the normal operation of power plant, the PCS air flow path is influenced by the external environment, and its internal flow is very complicated.
Designers are often lack of data support, and can’t fully consider the impact of environmental flow.
In order to fully study the performance of PCS air flow path, it is necessary to perform PCS integrated scaled wind tunnel test.
According to the original design of CAP1400 PCS system, the model scale research is developed and CAP1400 PCS wind tunnel test scaled model is established and the scale is 1:100.
The test model includes shield building model and the surrounding plant model, which contain pressure measuring points uniformly distributed in 6 horizontal cross sections of the shield building.
The pressure measuring point arrangement does not affect air flow in the air flow path.
The following wind tunnel tests are simulated in different wind speed including 15m/s, 20m/s, 10m/s, 25m/s.
The air flow pressure, wind velocity at the inlet and outlet of air flow path and the pressure distribution of inner annulus and outer annulus are measured in order to study the air flow pressure drop and wind-direction neutrality characteristics, and the wind tunnel test also considers the different wind direction angle, with and without the surrounding buildings and the effects of different landforms.
The test results show that the flow rate of inlet and outlet of air flow path is balanced and the wind velocity at the upwind and central area of the flow path outlet is larger than other area, and a large vortex comes on the leeward side near the wall.
The local uneven flow phenomenon exists in the outer annulus of the air flow path, but the wind pressure distribution of inner annulus is not affected by environment wind speed, wind direction angle, landforms and the surrounding buildings.
So CAP1400 PCS air flow path has the characteristics of wind direction neutrality, and the natural convection of the air flow path will not be adversely affected by the environment wind.

Related Results

Performance Test and Simulation Study on the Air Path of CAP1400 Passive Containment Cooling System
Performance Test and Simulation Study on the Air Path of CAP1400 Passive Containment Cooling System
As a large scale passive pressurized water reactor nuclear power plant, CAP1400 can remove the reactor decay heat to outside containment with the air cooling in the air flow path o...
Evaluation on CAP1400 Passive Containment Cooling System Capability
Evaluation on CAP1400 Passive Containment Cooling System Capability
CAP1400 is the large advanced passive demonstration plant, which is one of the National Science and Technology Major Projects. CAP1400 is an innovative design and development based...
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Background: In a wind farm, the wind speed of the downstream wind turbine will be lower than the wind speed of the upstream wind turbine due to the influence of the wake. Therefore...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
Large Scale Pressurized Water Reactor Passive Containment Cooling System Wind Tunnel Test
Large Scale Pressurized Water Reactor Passive Containment Cooling System Wind Tunnel Test
The objective of the current work is to shed light on studying the air flow features of the air path which is part of the passive containment cooling system (PCS) in a pressurized ...
Savonius Rotor for Offshore Wind Energy Conversion
Savonius Rotor for Offshore Wind Energy Conversion
Abstract Analysis of performance is presented for wind energy conversion by a Savonius type vertical axis rotor configured for generation of electrical power. The...
Deformation and Failure Mode Analysis of the Tunnel Structure Based on the Tunnel-Related Landslides Cases
Deformation and Failure Mode Analysis of the Tunnel Structure Based on the Tunnel-Related Landslides Cases
When the tunnel passes through the slope area, once the slope stability changes or landslide disasters occur, large additional stress, deformation, or cracking are easily caused in...

Back to Top