Performance Test and Simulation Study on the Air Path of CAP1400 Passive Containment Cooling System
View through CrossRef
As a large scale passive pressurized water reactor nuclear power plant, CAP1400 can remove the reactor decay heat to outside containment with the air cooling in the air flow path of passive containment cooling system (PCS) during the long-term period following an accident. Flow resistance characteristic and wind neutrality characteristic are the main performances of PCS air flow path. In order to study the performance of PCS air flow path, it is necessary to carry out the PCS wind tunnel test and computational fluid dynamics (CFD) analysis to establish a suitable method for the analysis of the performance of the air flow path.
This paper comes up simulating the internal pressure and velocity distribution in the air flow path under different wind speed through CAP1400 PCS 1:100 scaled air flow path wind tunnel test to research the air flow resistance and internal flow pattern. The test shows that local uneven flow phenomenon exists in the outer annulus of the air flow path, but the wind pressure distribution of inner annulus is not affected by environment wind speed, wind direction angle, landforms and the surrounding buildings. The wind pressure is uniform at different heights on the cross section and shows the neutrality feature.
Combining with CAP1400 PCS wind tunnel test, the CFD model is built. The measured inlet wind speed, turbulent kinetic energy and turbulent dissipation rate distribution parameters are inputs and the uniform wind conditions and gradient wind conditions of simulation analysis are developed. Simulation results show that:
1) In uniform wind condition, simulation result of pressure coefficient distribution trend at each cross section is consistent with the test trend and the deviation is very small, which basically can be controlled below 5%. The simulated differential pressures between inner annulus and outer annulus at different elevation are basically identical with the test results, which increase as the elevation arises. The simulated velocity distribution is basically identical with the test. The wind velocity at the upwind and central area of the flow path outlet is larger than other area, and a large swirling region comes on the leeward side near the wall 15cm, but simulated swirling region size at leeward side is slightly smaller.
2) In gradient wind condition, the pressure coefficient distribution trends are basically identical, and the deviation between the test and CFD analysis is 5–10% approximately. Considering the stability of gradient wind condition in wind tunnel is worse than that of uniform wind conditions, and more prone to wind speed fluctuations, therefore, the deviation is slightly greater than the uniform wind condition.
According to the CFD simulation and wind tunnel test, it can be found that the simulation of air flow inside and outside annulus has a high precision though the test results are slightly affected by the instrument tubes along the two sides of test model. In general, CFD simulation and wind tunnel test results are basically identical. Therefore, CFD analysis method is well verified by PCS wind tunnel test, which can be applied to the analysis of the actual power plant.
American Society of Mechanical Engineers
Title: Performance Test and Simulation Study on the Air Path of CAP1400 Passive Containment Cooling System
Description:
As a large scale passive pressurized water reactor nuclear power plant, CAP1400 can remove the reactor decay heat to outside containment with the air cooling in the air flow path of passive containment cooling system (PCS) during the long-term period following an accident.
Flow resistance characteristic and wind neutrality characteristic are the main performances of PCS air flow path.
In order to study the performance of PCS air flow path, it is necessary to carry out the PCS wind tunnel test and computational fluid dynamics (CFD) analysis to establish a suitable method for the analysis of the performance of the air flow path.
This paper comes up simulating the internal pressure and velocity distribution in the air flow path under different wind speed through CAP1400 PCS 1:100 scaled air flow path wind tunnel test to research the air flow resistance and internal flow pattern.
The test shows that local uneven flow phenomenon exists in the outer annulus of the air flow path, but the wind pressure distribution of inner annulus is not affected by environment wind speed, wind direction angle, landforms and the surrounding buildings.
The wind pressure is uniform at different heights on the cross section and shows the neutrality feature.
Combining with CAP1400 PCS wind tunnel test, the CFD model is built.
The measured inlet wind speed, turbulent kinetic energy and turbulent dissipation rate distribution parameters are inputs and the uniform wind conditions and gradient wind conditions of simulation analysis are developed.
Simulation results show that:
1) In uniform wind condition, simulation result of pressure coefficient distribution trend at each cross section is consistent with the test trend and the deviation is very small, which basically can be controlled below 5%.
The simulated differential pressures between inner annulus and outer annulus at different elevation are basically identical with the test results, which increase as the elevation arises.
The simulated velocity distribution is basically identical with the test.
The wind velocity at the upwind and central area of the flow path outlet is larger than other area, and a large swirling region comes on the leeward side near the wall 15cm, but simulated swirling region size at leeward side is slightly smaller.
2) In gradient wind condition, the pressure coefficient distribution trends are basically identical, and the deviation between the test and CFD analysis is 5–10% approximately.
Considering the stability of gradient wind condition in wind tunnel is worse than that of uniform wind conditions, and more prone to wind speed fluctuations, therefore, the deviation is slightly greater than the uniform wind condition.
According to the CFD simulation and wind tunnel test, it can be found that the simulation of air flow inside and outside annulus has a high precision though the test results are slightly affected by the instrument tubes along the two sides of test model.
In general, CFD simulation and wind tunnel test results are basically identical.
Therefore, CFD analysis method is well verified by PCS wind tunnel test, which can be applied to the analysis of the actual power plant.
Related Results
Evaluation on CAP1400 Passive Containment Cooling System Capability
Evaluation on CAP1400 Passive Containment Cooling System Capability
CAP1400 is the large advanced passive demonstration plant, which is one of the National Science and Technology Major Projects. CAP1400 is an innovative design and development based...
Large Scale PWR Passive Containment Cooling System Wind Tunnel Test
Large Scale PWR Passive Containment Cooling System Wind Tunnel Test
CAP1400 is a large passive pressurized water reactor nuclear power plant, which relies on engineering safety features such as passive containment cooling system (PCS) to remove the...
The Development and Application of the Engineering and Design Analyzer of CAP1400 Nuclear Power Plant
The Development and Application of the Engineering and Design Analyzer of CAP1400 Nuclear Power Plant
In the process of research and development for a new nuclear power plant, it is very necessary to develop a dynamic platform and tools to analyze and verify the plant control &...
Overview of the CAP1400 Reactor Hydraulic Simulation Tests
Overview of the CAP1400 Reactor Hydraulic Simulation Tests
CAP1400 is the trademark of a newly designed, by Shanghai Nuclear Engineering Research and Design Institute, third generation passive PWR. To verify the hydraulic functions and to ...
EFFECT OF AIR CONDITION ON AP-1000 CONTAINMENT COOLING PERFORMANCE IN STATION BLACK OUT ACCIDENT
EFFECT OF AIR CONDITION ON AP-1000 CONTAINMENT COOLING PERFORMANCE IN STATION BLACK OUT ACCIDENT
ABSTRACT EFFECT OF AIR CONDITION ON AP-1000 CONTAINMENT COOLING PERFORMANCE IN STATION BLACK OUT ACCIDENT. AP1000 reactor is a nuclear power plant generation III+ 1000 MWe which ap...
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Exposure to volatile organic compounds (VOC) in workplaces can cause acute effects such as irritation of the skin, the eyes, the mouth, and the nose. Some products may also cause c...
Study on Control Strategy of Hydrogen Risk in Small Containment Under Severe Accident
Study on Control Strategy of Hydrogen Risk in Small Containment Under Severe Accident
Hydrogen combustion or detonation happened in the containment within the process of the small reactor severe accident may threaten the integrity of the containment. In this paper, ...
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Abstract
In Large Gas Turbines, turbine components in particular blades and vanes operate at significantly high temperatures. As a result, cooling of these component...