Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Experimental and Numerical Study of Flexural Stiffness Performance of Ultra-Thin, Prefabricated, and Laminated Slab Base Slabs

View through CrossRef
To study the effects of different parameters on the short-term stiffness and cracking load of precast laminated base slabs, static loading experiments were conducted on five base slabs to obtain their damage patterns, stiffness changes, and deflection. The parametric research on the base slab’s short-term stiffness and cracking load was followed by changing the parameters, such as the truss height, truss spacing, and base slab thickness, using finite element refinement modeling based on test cases. The results show: (1) the ductility, short-term stiffness, and cracking load of the base slab can be significantly improved by reducing the truss spacing, and its short-term stiffness and cracking load with the 300 mm truss spacing are relatively improved by comparing to the 60 mm one; (2) increasing the height of truss improves the short-term stiffness, cracking load, and ductility of base slab; however, the improvements decrease with the increase of truss height. With consideration of the cost and construction requirements, the proper truss spacing is provided.
Title: Experimental and Numerical Study of Flexural Stiffness Performance of Ultra-Thin, Prefabricated, and Laminated Slab Base Slabs
Description:
To study the effects of different parameters on the short-term stiffness and cracking load of precast laminated base slabs, static loading experiments were conducted on five base slabs to obtain their damage patterns, stiffness changes, and deflection.
The parametric research on the base slab’s short-term stiffness and cracking load was followed by changing the parameters, such as the truss height, truss spacing, and base slab thickness, using finite element refinement modeling based on test cases.
The results show: (1) the ductility, short-term stiffness, and cracking load of the base slab can be significantly improved by reducing the truss spacing, and its short-term stiffness and cracking load with the 300 mm truss spacing are relatively improved by comparing to the 60 mm one; (2) increasing the height of truss improves the short-term stiffness, cracking load, and ductility of base slab; however, the improvements decrease with the increase of truss height.
With consideration of the cost and construction requirements, the proper truss spacing is provided.

Related Results

Experimental Study on Flexural Capacity of Corroded RC Slabs Reinforced with Basalt Fiber Textile
Experimental Study on Flexural Capacity of Corroded RC Slabs Reinforced with Basalt Fiber Textile
This experimental study investigated the flexural performance of corroded reinforced concrete (RC) slabs strengthened with basalt textile-reinforced mortar (BTRM) and basalt fiber-...
Seismic Response Optimization of RC Slabs: Influence of Opening Location, Size, and Geometry on Structural Performance
Seismic Response Optimization of RC Slabs: Influence of Opening Location, Size, and Geometry on Structural Performance
In this research, the influence of the location, area and shape of the openings on the seismic behavior and performance of the concrete slab roof was evaluated and studied using th...
Comparative Study of and Voided Slab System and Conventional RCC Slab
Comparative Study of and Voided Slab System and Conventional RCC Slab
This paper presents the flexural capacities of R.C.two-way hollow flat slabs with plastic voids. Recently, various types of slab systems which can reduce the self-weight of slabs h...
Clt Two-Way Slabs Fire Resistance Test and Numerical Simulation Analysis
Clt Two-Way Slabs Fire Resistance Test and Numerical Simulation Analysis
In order to investigate the failure mechanism and fire resistance of cross-laminated timber (CLT) two-way slabs at room temperature and under fire conditions, this paper conducted ...
Behavior of repaired heat-damaged self-compacted concrete slabs with openings using NSM-CFRP strips
Behavior of repaired heat-damaged self-compacted concrete slabs with openings using NSM-CFRP strips
PurposeIn this experimental investigation, the behavior of strengthened/repaired heat-damaged one-way self-compacted concrete (SCC) slabs with opening utilizing near-surface-mounte...
Application of laminated and cross-laminated timber in reconstruction and new construction
Application of laminated and cross-laminated timber in reconstruction and new construction
The article is devoted to the actual problem of restoration of construction objects of Ukraine destroyed as a result of military actions. The issue of manufacturing and effective a...
Development of sustainable concrete bridge deck slab systems using corrosion-resistant GRFP bars
Development of sustainable concrete bridge deck slab systems using corrosion-resistant GRFP bars
This research investigates the use of glass fiber reinforced polymer (GFRP) bars to reinforce the bridge deck slabs as well as jointed precast bridge deck slab in prefabricated bul...
Development of sustainable concrete bridge deck slab systems using corrosion-resistant GRFP bars
Development of sustainable concrete bridge deck slab systems using corrosion-resistant GRFP bars
This research investigates the use of glass fiber reinforced polymer (GFRP) bars to reinforce the bridge deck slabs as well as jointed precast bridge deck slab in prefabricated bul...

Back to Top