Javascript must be enabled to continue!
Optimisation of Header of a Compact Radiator
View through CrossRef
The performance of a Plate fin radiator in terms of heat transfer rate and coolant side pressure drop depends significantly on the distribution of coolant through its passages. Uneven flow through the passages i.e. flow maldistribution, can cause local hot spots in the radiator due to high coolant flow in some passages. The flow maldistribution among the passages can be reduced to a large extent by proper optimisation of the header. The present paper investigates the method to optimise the header of a 680 kW radiator to reduce the maldistribution in its passages using Computational Fluid Dynamics (CFD). The analysis was simplified by considering the porous media instead of simulating the exact fin configuration in the radiator. The maximum and absolute values of flow maldistribution factor were considered in this study to determine the effectiveness of the header with respect to flow maldistribution. The flow maldistribution factor was determined based on the individual velocity of coolant in a passage and the average velocity of coolant in all the passages. The methods used for optimisation were rounding the header inlet, tapering the header partially, changing the position of the taper and modifying the end portion of the header. In this paper two parameters, viz., flow maldistribution parameter and absolute maldistribution parameter were considered to measure the maldistribution of a radiator. Due to these optimisations in the header, the maximum and absolute values of maldistribution reduced up to 18% and 45% respectively.
Trans Tech Publications, Ltd.
Title: Optimisation of Header of a Compact Radiator
Description:
The performance of a Plate fin radiator in terms of heat transfer rate and coolant side pressure drop depends significantly on the distribution of coolant through its passages.
Uneven flow through the passages i.
e.
flow maldistribution, can cause local hot spots in the radiator due to high coolant flow in some passages.
The flow maldistribution among the passages can be reduced to a large extent by proper optimisation of the header.
The present paper investigates the method to optimise the header of a 680 kW radiator to reduce the maldistribution in its passages using Computational Fluid Dynamics (CFD).
The analysis was simplified by considering the porous media instead of simulating the exact fin configuration in the radiator.
The maximum and absolute values of flow maldistribution factor were considered in this study to determine the effectiveness of the header with respect to flow maldistribution.
The flow maldistribution factor was determined based on the individual velocity of coolant in a passage and the average velocity of coolant in all the passages.
The methods used for optimisation were rounding the header inlet, tapering the header partially, changing the position of the taper and modifying the end portion of the header.
In this paper two parameters, viz.
, flow maldistribution parameter and absolute maldistribution parameter were considered to measure the maldistribution of a radiator.
Due to these optimisations in the header, the maximum and absolute values of maldistribution reduced up to 18% and 45% respectively.
Related Results
Increased life expectancy of heart failure patients in a rural center by a multidisciplinary program
Increased life expectancy of heart failure patients in a rural center by a multidisciplinary program
Abstract
Funding Acknowledgements
Type of funding sources: None.
INTRODUCTION Patients with heart failure (HF)...
Primary PCI: a reasonable treatment for STEMI care during the COVID-19 pandemic
Primary PCI: a reasonable treatment for STEMI care during the COVID-19 pandemic
Abstract
Funding Acknowledgements
Type of funding sources: None.
Introduction
...
ANALISIS KERUSAKAN RADIATOR SEPEDA MOTOR 150cc
ANALISIS KERUSAKAN RADIATOR SEPEDA MOTOR 150cc
Sepeda motor yang mempunyai kapasitas mesin relativ besar memerlukan pendingin yang efisien agar ketika beroperasi tidak mengalami panas yang berlebihan sehingga dapat merusak mesi...
OPTIMALISASI SISTEM PENDINGIN ENGINE CATERPILLAR 3406E MILIK POLITEKNIK NEGERI JAKARTA
OPTIMALISASI SISTEM PENDINGIN ENGINE CATERPILLAR 3406E MILIK POLITEKNIK NEGERI JAKARTA
ABSTRACTAn engine can not be separated from the various systems in which is one of them is a cooling system, cooling system is the most important system in supporting the performan...
Robust design optimization of electrical machines for electric and hybrid vehicles
Robust design optimization of electrical machines for electric and hybrid vehicles
Contribution méthodologique au dimensionnement optimal et robuste des machines électriques dédiées aux chaines de traction VE et VEH
Face aux préoccupations croissa...
NON-HEADER IMPACT EXPOSURE AND KINEMATICS OF MALE YOUTH SOCCER PLAYERS
NON-HEADER IMPACT EXPOSURE AND KINEMATICS OF MALE YOUTH SOCCER PLAYERS
Previous studies have investigated the head impact kinematics of purposeful heading in youth soccer; however, less than a third of all head injuries in youth soccer have been foun...
Wideband microstrip dual polarization radiator for X-band APAA
Wideband microstrip dual polarization radiator for X-band APAA
In this paper the model and the construction of a wideband microstrip X-band radiator of active phased antenna arrays have been presented. The basic demands to the radiator have be...
The application of small size spiral tube coil antenna in the development of electromagnetic radiator
The application of small size spiral tube coil antenna in the development of electromagnetic radiator
Abstract
When the electromagnetic wave propagates in water, the attenuation will increase with the increase of frequency, so the application of electromagnetic wave ...

