Background:
Distal radius fractures are one of the most common injuries, representing one-sixth of all fractures seen and treated in the emergency department. Distal radial fractures with extensive comminution involving the metaphyseal–diaphyseal junction present a major treatment dilemma, especially when it has an intra-articular involvement. This study evaluates the surgical and functional outcomes of intra-articular comminuted fracture of distal end radius treated with dorsal distraction plating.
Materials and Methods:
A prospective randomized controlled observational study was done with a sample size of 50 patients over a period of 3 years, each of whom was diagnosed to have an intra-articular fracture of distal end radius (AO classification type C). All patients were treated by distraction plating (radio-metacarpal). Minimum follow-up after treatment of upto 6 months was ensured, and a final assessment of the functional outcome was then decided.
Results:
The study showed that average union time was 8.65 ± 0.93 weeks, and average implant removal was done at 8.75 ± 0.85 weeks. All patients achieved full ROM at the wrist, maintaining articular congruity post-implant removal. In our study, we found two (6.67%) patients with superficial infections and two (6.67%) patients with complex regional pain syndrome. No patients were reported with the tendon (extensor pollicis longus) irritation, neuropraxia, stiffness of the wrist and inter-phalangeal joints, nonunion/malunion, or implant failure.
Conclusion:
The final results were evaluated and compared after making observations for age, sex, mode of trauma, dominancy of the affected hand, time interval between injury and admission, duration of hospital stay, duration of surgery, time to fracture union, and complications. The final outcome was measured by DASH SCORE. All patients had excellent or good results treated with distraction plating; six (20.00%) patients out of 30 studies were found to have excellent results, whereas the remaining 24 (80.00%) patients had good results.
Ovid Technologies (Wolters Kluwer Health)
Title: An Assessment of Distraction Plating in the Management of Intra-Articular Comminuted Distal End Radius Fractures in the Elderly
Description:
Abstract
Background:
Distal radius fractures are one of the most common injuries, representing one-sixth of all fractures seen and treated in the emergency department.
Distal radial fractures with extensive comminution involving the metaphyseal–diaphyseal junction present a major treatment dilemma, especially when it has an intra-articular involvement.
This study evaluates the surgical and functional outcomes of intra-articular comminuted fracture of distal end radius treated with dorsal distraction plating.
Materials and Methods:
A prospective randomized controlled observational study was done with a sample size of 50 patients over a period of 3 years, each of whom was diagnosed to have an intra-articular fracture of distal end radius (AO classification type C).
All patients were treated by distraction plating (radio-metacarpal).
Minimum follow-up after treatment of upto 6 months was ensured, and a final assessment of the functional outcome was then decided.
Results:
The study showed that average union time was 8.
65 ± 0.
93 weeks, and average implant removal was done at 8.
75 ± 0.
85 weeks.
All patients achieved full ROM at the wrist, maintaining articular congruity post-implant removal.
In our study, we found two (6.
67%) patients with superficial infections and two (6.
67%) patients with complex regional pain syndrome.
No patients were reported with the tendon (extensor pollicis longus) irritation, neuropraxia, stiffness of the wrist and inter-phalangeal joints, nonunion/malunion, or implant failure.
Conclusion:
The final results were evaluated and compared after making observations for age, sex, mode of trauma, dominancy of the affected hand, time interval between injury and admission, duration of hospital stay, duration of surgery, time to fracture union, and complications.
The final outcome was measured by DASH SCORE.
All patients had excellent or good results treated with distraction plating; six (20.
00%) patients out of 30 studies were found to have excellent results, whereas the remaining 24 (80.
00%) patients had good results.
Related Results
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Introduction: The aim of this study is to illustrate a case in which the use of a dorsal spanning plate followed by volar plating may be indicated in the setting of a complex intra...
Comparative Analysis of Dorsal Distraction Plating Versus External Fixation in the Management of Intra-Articular Distal Radius Fractures
Comparative Analysis of Dorsal Distraction Plating Versus External Fixation in the Management of Intra-Articular Distal Radius Fractures
Introduction: Fractures located in close proximity to the lower end of the radius bone, which make up around 16% of fractures requiring emergency treatment require careful treatmen...
PANORAMIC REVIEW OF DISTAL RADIUS FRACTURES
PANORAMIC REVIEW OF DISTAL RADIUS FRACTURES
Introduction: fractures affecting the distal radius are common, their incidence increases as life expectancy increases, leading to a larger population of individuals at risk of suf...
An Alternative Fixation Technique for the Treatment of Comminuted Intra-Articular Distal Clavicle Fractures Using Contoured Reconstruction Bridging Plate
An Alternative Fixation Technique for the Treatment of Comminuted Intra-Articular Distal Clavicle Fractures Using Contoured Reconstruction Bridging Plate
Background:
Comminuted intra-articular distal end clavicular fractures are rare type fractures, which cannot be fixed with standard fixation methods. This work aimed to...
Incidence of Anti-osteoporosis Diagnosis and Treatment After Distal Radius Fractures
Incidence of Anti-osteoporosis Diagnosis and Treatment After Distal Radius Fractures
Introduction: There is still lack of adequate diagnosis and treatment of osteoporosis in elderly patients. Hand surgeons can prevent secondary osteoporotic fractures when treating ...
998 Distal Radius Fractures – Assessing Time to Surgery
998 Distal Radius Fractures – Assessing Time to Surgery
Abstract
Background
The British Orthopaedic Association Standards for Trauma (BOAST guidelines) recommend that intra-articular d...
Functional Outcome of Intra-Articular Distal Humerus Fracture Fixation by Orthogonal Plating – In Indian Population: A Case Series
Functional Outcome of Intra-Articular Distal Humerus Fracture Fixation by Orthogonal Plating – In Indian Population: A Case Series
Introduction: The study aimed to evaluate the functional outcomes by treating intra-articular distal humerus fractures using orthogonal plating, with or without olecranon osteotomy...
Clinical Outcomes of Intra-Articular Distal Radius Fractures Treated with Volar Locking Plate Fixation
Clinical Outcomes of Intra-Articular Distal Radius Fractures Treated with Volar Locking Plate Fixation
Distal radius fractures are extremely common, accounting for one-sixth of all fractures seen in the emergency department. Intra-articular fractures present a greater challenge due ...