Javascript must be enabled to continue!
Auxetic femur meta-implants with tuned micromotion distribution
View through CrossRef
Stress shielding and micromotions are the most significant problems occurring at the bone-implants interface due to mismatch of their mechanical properties. Mechanical metamaterials with their exceptional behavior and characteristics, can provide an opportunity to solve the mismatch of mechanical properties between the bone and implant. In this study, four types of human femoral hip implants (one solid implant and three lattice-structured meta-implants) have been considered for stress and micromotion analysis. For this aim, at the first stage, a well-known auxetic 3D re-entrant structure was studied analytically, and precise closed-form analytical relationships for elastic modulus and Poisson’s ratio of the unit cell were obtained. The analytical solution was validated with the numerical solution based on beam elements. At the second stage, three lattice meta-implants made of 3D re-entrant unit cells with positive, negative, and graded distribution of Poisson’s ratio were analyzed and the stress and strain distributions in implant and the micromotion at the bone-implant interface were studied. The results of analytical solution for mechanical properties of the 3D re-entrant structure presented great improvements in comparison with previous analytical studies on this structure. Moreover, the implementation of the re-entrant structure in the hip implant provided very smooth results for stress and strain distributions in the lattice meta-implants and could solve the stress shielding problem which occurred in the solid implant. The lattice meta-implant based on the graded unit cell distribution presented smoother stress-strain distribution in comparison with the other lattice meta-implants. Moreover, the graded lattice meta-implant gave minimum areas of local stress and local strain concentration at the contact region of the implants with the internal bone surfaces. Among all the cases, the graded meta-implant also gave micromotion levels which are the closest to values reported to be desirable for bone growth (40 µm).
Title: Auxetic femur meta-implants with tuned micromotion distribution
Description:
Stress shielding and micromotions are the most significant problems occurring at the bone-implants interface due to mismatch of their mechanical properties.
Mechanical metamaterials with their exceptional behavior and characteristics, can provide an opportunity to solve the mismatch of mechanical properties between the bone and implant.
In this study, four types of human femoral hip implants (one solid implant and three lattice-structured meta-implants) have been considered for stress and micromotion analysis.
For this aim, at the first stage, a well-known auxetic 3D re-entrant structure was studied analytically, and precise closed-form analytical relationships for elastic modulus and Poisson’s ratio of the unit cell were obtained.
The analytical solution was validated with the numerical solution based on beam elements.
At the second stage, three lattice meta-implants made of 3D re-entrant unit cells with positive, negative, and graded distribution of Poisson’s ratio were analyzed and the stress and strain distributions in implant and the micromotion at the bone-implant interface were studied.
The results of analytical solution for mechanical properties of the 3D re-entrant structure presented great improvements in comparison with previous analytical studies on this structure.
Moreover, the implementation of the re-entrant structure in the hip implant provided very smooth results for stress and strain distributions in the lattice meta-implants and could solve the stress shielding problem which occurred in the solid implant.
The lattice meta-implant based on the graded unit cell distribution presented smoother stress-strain distribution in comparison with the other lattice meta-implants.
Moreover, the graded lattice meta-implant gave minimum areas of local stress and local strain concentration at the contact region of the implants with the internal bone surfaces.
Among all the cases, the graded meta-implant also gave micromotion levels which are the closest to values reported to be desirable for bone growth (40 µm).
Related Results
Preface: phys. stat. sol. (b) 244/3
Preface: phys. stat. sol. (b) 244/3
AbstractThis is the 2nd special issue of physica status solidi (b) dedicated to materials exhibiting negative Poisson's ratio (auxetic) or other unusual or counter‐intuitive physic...
Force Analysis of Magnetic Levitation Micromotion Stage
Force Analysis of Magnetic Levitation Micromotion Stage
This A new method of magnetic levitation micromotion of AC / DC hybrid driving is presented in this paper presents, and a new magnetic levitation micromotion stage has been designe...
Preface: phys. stat. sol. (b) 242/3
Preface: phys. stat. sol. (b) 242/3
AbstractThis special issue of physica status solidi (b) is dedicated to papers presented, or in a few cases additional to, the Workshop on Auxetics and Related Systems held during ...
Effect of Compressive Strain Rate on Auxetic Foam
Effect of Compressive Strain Rate on Auxetic Foam
Auxetic foams have previously been shown to have benefits including higher indentation resistance than their conventional counterparts, due to their negative Poisson’s ratio, makin...
Risk factors, classification, and operative choices of femur fractures at a Tertiary Hospital: first report from Somalia
Risk factors, classification, and operative choices of femur fractures at a Tertiary Hospital: first report from Somalia
AbstractA traumatic femur fracture is a significant cause of morbidity, affecting one to three million individuals annually. The present is the first study investigated the epidemi...
Clinical outcomes of zirconia implants: a systematic review and meta-analysis
Clinical outcomes of zirconia implants: a systematic review and meta-analysis
Abstract
Purpose
To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review.
...
New Acupuncture Treatment Points of Cancer & Detecting Points of Cancer
New Acupuncture Treatment Points of Cancer & Detecting Points of Cancer
Introduction
By using electro-conductive wire from cancer reactive area, treatment point should be detective and acupuncture & moxibustion would be effectiv...
Determination of Height Using Femur Length in Adult Population of Oguta Local Government Area of Imo State Nigeria
Determination of Height Using Femur Length in Adult Population of Oguta Local Government Area of Imo State Nigeria
The use of body parts in the estimation of stature is a vital tool in forensic anthropology. This research was carried out to determine the height of adult population of Oguta inha...

