The sonographic evaluation of tubal patency with stimulated acoustic emission imaging

View through CrossRef
AbstractObjectivesExperimental and clinical data suggest that insonation of echo‐enhancing contrast agents with high acoustic power produces disintegration of microbubbles, resulting in a phenomenon called stimulated acoustic emission (SAE). The purpose of this study was to investigate whether SAE might be detected by transvaginal sonography and whether this technique may be useful in the assessment of tubal patency by hysterosalpingo‐contrast sonography (SAE‐HyCoSy).MethodsPatients booked for X‐ray hysterosalpingography (HSG) for infertility evaluation also received SAE‐HyCoSy. The order of the two procedures was established in each patient by randomization after placement of a transcervical balloon catheter. For SAE‐HyCoSy, the ultrasound contrast medium Levovist was injected, with the acoustic power set at the maximum level permitted on ultrasound machines employing dedicated algorithms. Conventional HSG was performed for comparison.ResultsSeventy‐seven Fallopian tubes were examined in 41 patients. In all cases it was possible to obtain the SAE phenomenon. In 10 tubes (13%) proximal filling was not observed by both SAE‐HyCoSy and HSG. In the remaining 67 tubes, free spill from the distal end of the lumen was demonstrated in 96% of cases (64/67) with SAE‐HyCoSy and in 97% of cases (65/67) with HSG. Disagreement between the two techniques was observed in five tubes only, with a Cohen's κ coefficient of 0.76 (95% confidence interval, 0.56–0.96).ConclusionSAE techniques were successfully applied to HyCoSy and allowed the visualization of the free spill of contrast agent into the peritoneal cavity in the majority of cases. SAE‐HyCoSy showed good agreement with HSG in this preliminary study. Copyright © 2002 International Society of Ultrasound in Obstetrics and Gynecology
Title: The sonographic evaluation of tubal patency with stimulated acoustic emission imaging
Description:
AbstractObjectivesExperimental and clinical data suggest that insonation of echo‐enhancing contrast agents with high acoustic power produces disintegration of microbubbles, resulting in a phenomenon called stimulated acoustic emission (SAE).
The purpose of this study was to investigate whether SAE might be detected by transvaginal sonography and whether this technique may be useful in the assessment of tubal patency by hysterosalpingo‐contrast sonography (SAE‐HyCoSy).
MethodsPatients booked for X‐ray hysterosalpingography (HSG) for infertility evaluation also received SAE‐HyCoSy.
The order of the two procedures was established in each patient by randomization after placement of a transcervical balloon catheter.
For SAE‐HyCoSy, the ultrasound contrast medium Levovist was injected, with the acoustic power set at the maximum level permitted on ultrasound machines employing dedicated algorithms.
Conventional HSG was performed for comparison.
ResultsSeventy‐seven Fallopian tubes were examined in 41 patients.
In all cases it was possible to obtain the SAE phenomenon.
In 10 tubes (13%) proximal filling was not observed by both SAE‐HyCoSy and HSG.
In the remaining 67 tubes, free spill from the distal end of the lumen was demonstrated in 96% of cases (64/67) with SAE‐HyCoSy and in 97% of cases (65/67) with HSG.
Disagreement between the two techniques was observed in five tubes only, with a Cohen's κ coefficient of 0.
76 (95% confidence interval, 0.
56–0.
96).
ConclusionSAE techniques were successfully applied to HyCoSy and allowed the visualization of the free spill of contrast agent into the peritoneal cavity in the majority of cases.
SAE‐HyCoSy showed good agreement with HSG in this preliminary study.
Copyright © 2002 International Society of Ultrasound in Obstetrics and Gynecology.

Related Results

Automated three‐dimensional coded contrast imaging hysterosalpingo‐contrast sonography: feasibility in office tubal patency testing
Automated three‐dimensional coded contrast imaging hysterosalpingo‐contrast sonography: feasibility in office tubal patency testing
ABSTRACTObjectiveTo evaluate the feasibility of transvaginal hysterosalpingo‐contrast sonography (HyCoSy) with new automated three‐dimensional coded contrast imaging (3D‐CCI) softw...
Study of Saline Infusion Sonography and Hysterosalpingography to See the Tubal Patency in the Infertile Women
Study of Saline Infusion Sonography and Hysterosalpingography to See the Tubal Patency in the Infertile Women
Background: Infertility is a global issue in reproductive health. Etiology Of infertility is multifactorial and fallopian tube abnormality being one of the most important causes ac...
Comparison of Saline Infusion Sonography with Hysterosalpingography for its Accuracy in Diagnosing Tubal Status in Subfertile Females
Comparison of Saline Infusion Sonography with Hysterosalpingography for its Accuracy in Diagnosing Tubal Status in Subfertile Females
Background: Subfertility is seen in approximately 10-15% of couples of reproductive ages. Tubal factors account for 25-35% of cases of subfertility. Commonly used tests for tubal p...
Tubal flushing
Tubal flushing
Infertility is a significant global health issue, affecting approximately 17% of couples at some point in their lives. Couples facing infertility report poorer mental health outcom...
Suture-Induced Tubo-Ovarian Abscess: A Case Report with Literature Review
Suture-Induced Tubo-Ovarian Abscess: A Case Report with Literature Review
Abstract Introduction Suture is an underreported cause for tubo-ovarian abscess (TOA) that can cause significant morbidity. This report describes a case of TOA arising from a silk ...

Back to Top