Automated three‐dimensional coded contrast imaging hysterosalpingo‐contrast sonography: feasibility in office tubal patency testing

View through CrossRef
ABSTRACTObjectiveTo evaluate the feasibility of transvaginal hysterosalpingo‐contrast sonography (HyCoSy) with new automated three‐dimensional coded contrast imaging (3D‐CCI) software in the evaluation of tubal patency and visualization of tubal course.MethodsPatients undergoing HyCoSy with automated 3D‐CCI software were evaluated prospectively. First, to evaluate the feasibility of 3D visualization of tubal course, we performed consecutive volume acquisitions while injecting SonoVue contrast agent. We then performed conventional two‐dimensional (2D) real‐time HyCoSy to confirm tubal patency status by detection of saline and air bubbles moving through the Fallopian tubes and around the ovaries. We also evaluated visualization with CCI of the contrast agent around the ovaries, side effects and pain during and after the procedure, by visual analog scale (VAS) (ranging from 0 to 10, with 0 corresponding to no pain and 10 corresponding to maximum pain).ResultsA total of 126 patients (252 tubes) underwent 3D‐CCI HyCoSy followed by 2D real‐time HyCoSy. According to the final 2D real‐time evaluation, bilateral tubal patency was observed in 111 patients, bilateral tubal occlusion in four patients and unilateral tubal patency in 11 patients. The concordance rate for tubal patency status between the first 3D volume acquisition and the final 2D real‐time evaluation was 84% and that between the second 3D volume acquisition and the final 2D real‐time evaluation was 97%. A pain score >5 on VAS was recorded in 58% of patients during the procedure, but a pain score ≤ 5 was recorded in 85.7% of patients immediately after the procedure.ConclusionsHyCoSy with automated 3D‐CCI technology retains the advantages of conventional 2D HyCoSy while overcoming the disadvantages. 2D HyCoSy is highly observer‐dependent and is only accurate in the hands of experienced investigators; by obtaining a volume of the uterus and tubes, automated 3D volume acquisition permits visualization of the tubes in the coronal view and of the tubal course in 3D space, and should allow less experienced operators to evaluate tubal patency status relatively easily. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.
Title: Automated three‐dimensional coded contrast imaging hysterosalpingo‐contrast sonography: feasibility in office tubal patency testing
Description:
ABSTRACTObjectiveTo evaluate the feasibility of transvaginal hysterosalpingo‐contrast sonography (HyCoSy) with new automated three‐dimensional coded contrast imaging (3D‐CCI) software in the evaluation of tubal patency and visualization of tubal course.
MethodsPatients undergoing HyCoSy with automated 3D‐CCI software were evaluated prospectively.
First, to evaluate the feasibility of 3D visualization of tubal course, we performed consecutive volume acquisitions while injecting SonoVue contrast agent.
We then performed conventional two‐dimensional (2D) real‐time HyCoSy to confirm tubal patency status by detection of saline and air bubbles moving through the Fallopian tubes and around the ovaries.
We also evaluated visualization with CCI of the contrast agent around the ovaries, side effects and pain during and after the procedure, by visual analog scale (VAS) (ranging from 0 to 10, with 0 corresponding to no pain and 10 corresponding to maximum pain).
ResultsA total of 126 patients (252 tubes) underwent 3D‐CCI HyCoSy followed by 2D real‐time HyCoSy.
According to the final 2D real‐time evaluation, bilateral tubal patency was observed in 111 patients, bilateral tubal occlusion in four patients and unilateral tubal patency in 11 patients.
The concordance rate for tubal patency status between the first 3D volume acquisition and the final 2D real‐time evaluation was 84% and that between the second 3D volume acquisition and the final 2D real‐time evaluation was 97%.
A pain score >5 on VAS was recorded in 58% of patients during the procedure, but a pain score ≤ 5 was recorded in 85.
7% of patients immediately after the procedure.
ConclusionsHyCoSy with automated 3D‐CCI technology retains the advantages of conventional 2D HyCoSy while overcoming the disadvantages.
2D HyCoSy is highly observer‐dependent and is only accurate in the hands of experienced investigators; by obtaining a volume of the uterus and tubes, automated 3D volume acquisition permits visualization of the tubes in the coronal view and of the tubal course in 3D space, and should allow less experienced operators to evaluate tubal patency status relatively easily.
Copyright © 2012 ISUOG.
Published by John Wiley & Sons, Ltd.

Related Results

Study of Saline Infusion Sonography and Hysterosalpingography to See the Tubal Patency in the Infertile Women
Study of Saline Infusion Sonography and Hysterosalpingography to See the Tubal Patency in the Infertile Women
Background: Infertility is a global issue in reproductive health. Etiology Of infertility is multifactorial and fallopian tube abnormality being one of the most important causes ac...
Comparison of Saline Infusion Sonography with Hysterosalpingography for its Accuracy in Diagnosing Tubal Status in Subfertile Females
Comparison of Saline Infusion Sonography with Hysterosalpingography for its Accuracy in Diagnosing Tubal Status in Subfertile Females
Background: Subfertility is seen in approximately 10-15% of couples of reproductive ages. Tubal factors account for 25-35% of cases of subfertility. Commonly used tests for tubal p...
Tubal flushing
Tubal flushing
Infertility is a significant global health issue, affecting approximately 17% of couples at some point in their lives. Couples facing infertility report poorer mental health outcom...
Suture-Induced Tubo-Ovarian Abscess: A Case Report with Literature Review
Suture-Induced Tubo-Ovarian Abscess: A Case Report with Literature Review
Abstract Introduction Suture is an underreported cause for tubo-ovarian abscess (TOA) that can cause significant morbidity. This report describes a case of TOA arising from a silk ...
Cutaneous small‐vessel vasculitis following hysterosalpingo‐foam sonography (HyFoSy)
Cutaneous small‐vessel vasculitis following hysterosalpingo‐foam sonography (HyFoSy)
ABSTRACTWe present a case of diffuse skin immune reaction, diagnosed as cutaneous small‐vessel vasculitis, following assessment of tubal patency by contrast ultrasound, which appea...

Back to Top