Complex Calorimeter with AC- and Relaxation-Mode Operation
View through CrossRef
A complex calorimeter has been developed. This calorimeter, which can be operated both in the ac mode and the relaxation mode using the same sample cell and the same apparatus settings, uses only a small amount (30-50 mg) of sample. An application to measurements in the vicinity of the antiferroelectric phase transitions in the liquid crystal MHPOBC(4-(1-methylheptyloxycarbonyl)-phenyl 4'-octyloxybiphenyl-4-carboxylate) is demonstrated. It is shown that the present calorimeter, when operated in the relaxation mode, enables detection of the latent heat with a resolution of 0.002 J/g.
Title: Complex Calorimeter with AC- and Relaxation-Mode Operation
Description:
A complex calorimeter has been developed.
This calorimeter, which can be operated both in the ac mode and the relaxation mode using the same sample cell and the same apparatus settings, uses only a small amount (30-50 mg) of sample.
An application to measurements in the vicinity of the antiferroelectric phase transitions in the liquid crystal MHPOBC(4-(1-methylheptyloxycarbonyl)-phenyl 4'-octyloxybiphenyl-4-carboxylate) is demonstrated.
It is shown that the present calorimeter, when operated in the relaxation mode, enables detection of the latent heat with a resolution of 0.
002 J/g.
Related Results
Designing Calorimeter Made from Various Wastes
Designing Calorimeter Made from Various Wastes
<p>A research has been conducted which aims to design a waste-based calorimeter as an alternative to measuring heat for chemistry practicum in schools. Research products deve...
Comprehensive analysis of relaxation decays from high-resolution relaxometry
Comprehensive analysis of relaxation decays from high-resolution relaxometry
Relaxometry consists in measuring relaxation rates over orders of magnitude of magnetic fields to probe motions of complex systems. High-resolution relaxometry (HRR) experiments ca...
Comprehensive analysis of relaxation decays from high-resolution relaxometry
Comprehensive analysis of relaxation decays from high-resolution relaxometry
Relaxometry consists in measuring relaxation rates over orders of magnitude of magnetic fields to probe motions of complex systems. High-resolution relaxometry (HRR) experiments ca...
Threads of time
Threads of time
This thesis advances the fundamental understanding of dilute polymer solution rheology through systematic investigation of extensional flow behavior, with particular focus on polye...
A novel on-chip three-dimensional micromachined calorimeter with fully enclosed and suspended thin-film chamber for thermal characterization of liquid samples
A novel on-chip three-dimensional micromachined calorimeter with fully enclosed and suspended thin-film chamber for thermal characterization of liquid samples
A microfabricated calorimeter (μ-calorimeter) with an enclosed reaction chamber is presented. The 3D micromachined reaction chamber is capable of analyzing liquid samples with volu...
Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry
Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry
New calorimeter technology is being developed for future collider experiments. We are developing a calorimeter that integrates two technologies, a high-granularity calorimeter and ...
Comparative Studies on Rabbit Corpus Cavernosal Contraction and Relaxation. An In Vitro Study
Comparative Studies on Rabbit Corpus Cavernosal Contraction and Relaxation. An In Vitro Study
ABSTRACT: Erectile function (erection and detumescence) involves the complex interaction of direct neuronal stimulation of corporal smooth muscle, neurohumoral release of specific...
Vibrational relaxation of H2O from 295 to 1020 K
Vibrational relaxation of H2O from 295 to 1020 K
A laser induced fluorescence/heated flow tube method has been used to measure rate constants for vibrational relaxation of the coupled ν1 and ν3 stretching levels, the 2ν2 bending ...