Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Application of a Silicon Calorimeter in Fast Burst Reactor Environments

View through CrossRef
Abstract Frequently in experiments at fast burst reactors (FBRs), it is necessary to know the dose and peak dose rate absorbed by a material in terms of dose to silicon. The dose to silicon at a given point in an irradiation cannot be reliably measured by a passive dosimeter retrieved at late times from a mixed field environment, so we rely on the silicon calorimeter as the true standard. A silicon calorimeter has been developed for applications in a water-moderated pulsed reactor. In this paper, the authors investigate the application of this silicon calorimeter in an FBR environment. Tests have been conducted at the White Sands Missile Range (WSMR) FBR, also known as MoLLY-G, to develop techniques to use this silicon calorimeter for a measure of rad(Si) during and soon after a pulsed operation. This calorimeter can be coupled with the response of a diamond photoconductive detector (PCD) in order to derive a dose rate monitor suitable for application during an FBR operation [1].
Title: Application of a Silicon Calorimeter in Fast Burst Reactor Environments
Description:
Abstract Frequently in experiments at fast burst reactors (FBRs), it is necessary to know the dose and peak dose rate absorbed by a material in terms of dose to silicon.
The dose to silicon at a given point in an irradiation cannot be reliably measured by a passive dosimeter retrieved at late times from a mixed field environment, so we rely on the silicon calorimeter as the true standard.
A silicon calorimeter has been developed for applications in a water-moderated pulsed reactor.
In this paper, the authors investigate the application of this silicon calorimeter in an FBR environment.
Tests have been conducted at the White Sands Missile Range (WSMR) FBR, also known as MoLLY-G, to develop techniques to use this silicon calorimeter for a measure of rad(Si) during and soon after a pulsed operation.
This calorimeter can be coupled with the response of a diamond photoconductive detector (PCD) in order to derive a dose rate monitor suitable for application during an FBR operation [1].

Related Results

Phytolith extraction and counting procedure for modern plant material rich in silica skeletons v1
Phytolith extraction and counting procedure for modern plant material rich in silica skeletons v1
Modern plant tissues are often processed for phytolith analysis. They represent a fundamental source of comparison for archeological and palaeoenvironmental phytolith assemblages; ...
Phytolith extraction and counting procedure for modern plant material rich in silica skeletons v2
Phytolith extraction and counting procedure for modern plant material rich in silica skeletons v2
Modern plant tissues are often processed for phytolith analysis. They represent a fundamental source of comparison for archeological and palaeoenvironmental phytolith assemblages; ...
Phytolith extraction and counting procedure for modern plant material rich in silica skeletons v1
Phytolith extraction and counting procedure for modern plant material rich in silica skeletons v1
Modern plant tissues are often processed for phytolith analysis. They represent a fundamental source of comparison for archeological and palaeoenvironmental phytolith assemblages; ...
ANALISIS PENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM
ANALISIS PENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM
ANALISISPENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM POST REACTOR SCRAM CONTROL RODS POSITION ADJUSTMENT ANALYSIS FOR THE IN...
Eliminación biológica de nutrientes en un ARU de baja carga orgánica mediante el proceso VIP
Eliminación biológica de nutrientes en un ARU de baja carga orgánica mediante el proceso VIP
El objetivo principal de esta tesis doctoral es profundizar en el conocimiento de los procesos biológicos responsables de la eliminación simultánea de nitrógeno y fósforo en un ARU...
Developmental Review and Critical Analysis of Burst Assembly Schemes in Optical Burst Switching Networks
Developmental Review and Critical Analysis of Burst Assembly Schemes in Optical Burst Switching Networks
Burst assembly is a critical process in optical burst switching (OBS) networks that aggregates packets in the ingress node into bursts for efficient optical transmission. This proc...
Time-course of host cell transcription during the HTLV-1 transcriptional burst
Time-course of host cell transcription during the HTLV-1 transcriptional burst
Abstract The human T-cell leukemia virus type 1 (HTLV-1) transactivator protein Tax has pleiotropic functions in the host cell affecting cell-cyc...
GIRK Channel Activation Contributes to the Muscarinic Modulation of XII Motoneuron Excitability in Neonatal Mice in Vitro
GIRK Channel Activation Contributes to the Muscarinic Modulation of XII Motoneuron Excitability in Neonatal Mice in Vitro
Sleep specific decreases in airway muscle tone, and particularly the genioglossus muscle of the tongue (primary tongue protruder), have been causally implicated in obstructive slee...

Back to Top