Harmonic source localization method adapted to dynamic changes in distribution network topology

View through CrossRef
A great number of renewable energy sources and nonlinear loads are integrated into the distribution systems through power electronic converters, which leads to serious harmonic distortions. Correctly determining the location of harmonic sources is the primary task to manage the harmonic pollution users and develop a strategy for harmonic suppression on system level. Existing localization methods leverage the time-domain waveforms of voltage and currents across each feeder. Meanwhile, an accurate knowledge of network topology and line impedances are also required. However, these are difficult to meet in engineering practice. Only the RMS values of harmonics are uploaded from the power quality sensors to distribution management system. Besides, a small change of network topology would produce a totally wrong location result. In this letter, a harmonic source localization method based on Dynamic Graph Convolutional Recurrent Network (DGCRN) is proposed. Only the RMS values of harmonics and pre-defined topology of distribution systems are required to capture the spatio-temporal correlations between harmonic sources and harmonic distortion nodes. The effectiveness of the proposed method is tested in the IEEE14 distribution network. By using the same test set, the accuracy of proposed method is improved by 8.42% over the spatio-temporal graph convolutional network (STGCN).
Title: Harmonic source localization method adapted to dynamic changes in distribution network topology
Description:
A great number of renewable energy sources and nonlinear loads are integrated into the distribution systems through power electronic converters, which leads to serious harmonic distortions.
Correctly determining the location of harmonic sources is the primary task to manage the harmonic pollution users and develop a strategy for harmonic suppression on system level.
Existing localization methods leverage the time-domain waveforms of voltage and currents across each feeder.
Meanwhile, an accurate knowledge of network topology and line impedances are also required.
However, these are difficult to meet in engineering practice.
Only the RMS values of harmonics are uploaded from the power quality sensors to distribution management system.
Besides, a small change of network topology would produce a totally wrong location result.
In this letter, a harmonic source localization method based on Dynamic Graph Convolutional Recurrent Network (DGCRN) is proposed.
Only the RMS values of harmonics and pre-defined topology of distribution systems are required to capture the spatio-temporal correlations between harmonic sources and harmonic distortion nodes.
The effectiveness of the proposed method is tested in the IEEE14 distribution network.
By using the same test set, the accuracy of proposed method is improved by 8.
42% over the spatio-temporal graph convolutional network (STGCN).

Related Results

Indoor Localization System Based on RSSI-APIT Algorithm
Indoor Localization System Based on RSSI-APIT Algorithm
An indoor localization system based on the RSSI-APIT algorithm is designed in this study. Integrated RSSI (received signal strength indication) and non-ranging APIT (approximate pe...
A Topology Identification Monitoring Terminal Based on the Pulse Current Characteristic Analysis
A Topology Identification Monitoring Terminal Based on the Pulse Current Characteristic Analysis
Abstract The low-voltage distribution network field wiring is very complicated and there are many changes in the relationship between households and changes, which b...
High-Harmonic Injection-Based Brushless Wound Field Synchronous Machine Topology
High-Harmonic Injection-Based Brushless Wound Field Synchronous Machine Topology
This paper discusses the design and analysis of a high-harmonic injection-based field excitation scheme for the brushless operation of wound field synchronous machines (WFSMs) in o...
Modelling and analysis of LCC‐HVDC converter station for harmonic coupling of AC/DC power grid during geomagnetic storm
Modelling and analysis of LCC‐HVDC converter station for harmonic coupling of AC/DC power grid during geomagnetic storm
AbstractIn this paper, the problem of harmonic coupling between the converter transformer and the converter under the action of geomagnetically induced current (GIC) is proposed to...
Extractraction of non-stationary harmonic from chaotic background based on synchrosqueezed wavelet transform
Extractraction of non-stationary harmonic from chaotic background based on synchrosqueezed wavelet transform
The signal detection in chaotic background has gradually become one of the research focuses in recent years. Previous research showed that the measured signals were often unavoidab...
Torque Improvement of Six-Phase Permanent-Magnet Synchronous Machine Drive with Fifth-Harmonic Current Injection for Electric Vehicles
Torque Improvement of Six-Phase Permanent-Magnet Synchronous Machine Drive with Fifth-Harmonic Current Injection for Electric Vehicles
This paper proposes a method to improve the output torque of a six-phase permanent-magnet synchronous machine (PMSM) within the same current peak limit through a fifth-harmonic inj...

Back to Top