Javascript must be enabled to continue!
Modelling and analysis of LCC‐HVDC converter station for harmonic coupling of AC/DC power grid during geomagnetic storm
View through CrossRef
AbstractIn this paper, the problem of harmonic coupling between the converter transformer and the converter under the action of geomagnetically induced current (GIC) is proposed to be investigated. Firstly, a model of a 12‐pulse line commutated converter high voltage direct current (LCC‐HVDC) converter station based on harmonic state space (HSS) theory is established. Secondly, the harmonic components of the interaction between the AC‐side harmonic current and the DC‐side harmonic voltage are qualitatively analyzed by using the harmonic modulation theory. Through the simulation model and harmonic state space (HSS) calculation model, the harmonic coupling characteristics of power grid are analyzed. Finally, the harmonic current and voltage amplitude of AC / DC power grid under different GIC are calculated, and the characteristics and rules of AC / DC harmonic propagation are revealed. Among them, the amplitude of the 2nd harmonic current on the AC side and the 3rd harmonic current on the DC side increases linearly with the GIC. In addition, the 3rd and 9th harmonics on the AC side are also greatly affected by the magnetic bias of the converter.
Institution of Engineering and Technology (IET)
Title: Modelling and analysis of LCC‐HVDC converter station for harmonic coupling of AC/DC power grid during geomagnetic storm
Description:
AbstractIn this paper, the problem of harmonic coupling between the converter transformer and the converter under the action of geomagnetically induced current (GIC) is proposed to be investigated.
Firstly, a model of a 12‐pulse line commutated converter high voltage direct current (LCC‐HVDC) converter station based on harmonic state space (HSS) theory is established.
Secondly, the harmonic components of the interaction between the AC‐side harmonic current and the DC‐side harmonic voltage are qualitatively analyzed by using the harmonic modulation theory.
Through the simulation model and harmonic state space (HSS) calculation model, the harmonic coupling characteristics of power grid are analyzed.
Finally, the harmonic current and voltage amplitude of AC / DC power grid under different GIC are calculated, and the characteristics and rules of AC / DC harmonic propagation are revealed.
Among them, the amplitude of the 2nd harmonic current on the AC side and the 3rd harmonic current on the DC side increases linearly with the GIC.
In addition, the 3rd and 9th harmonics on the AC side are also greatly affected by the magnetic bias of the converter.
Related Results
KONTESTASI TASAWUF SUNNÎ DAN TASAWUF FALSAFÎ DI NUSANTARA
KONTESTASI TASAWUF SUNNÎ DAN TASAWUF FALSAFÎ DI NUSANTARA
<p>This article scrutinizes the history of Islamic development in Nusantara between 15th to 18th centuries, which has been colored from theological mysticism thought. Uniquel...
Korelasi Kadar Karboksihemoglobin terhadap Tekanan Darah Penduduk di Sekitar Terminal Bus Tirtonadi Surakarta
Korelasi Kadar Karboksihemoglobin terhadap Tekanan Darah Penduduk di Sekitar Terminal Bus Tirtonadi Surakarta
<table width="645" border="1" cellspacing="0" cellpadding="0"><tbody><tr><td valign="top" width="408"><p> </p><p>Carbon monoxide is a gas ...
Coordinated Control of HVDC and HVAC Power Transmission Systems Integrating a Large Offshore Wind Farm
Coordinated Control of HVDC and HVAC Power Transmission Systems Integrating a Large Offshore Wind Farm
The development of efficient and reliable offshore electrical transmission infrastructure is a key factor in the proliferation of offshore wind farms (OWFs). Traditionally, high-vo...
Efeitos do Pilates solo e exercício resistido sobre a obesidade central e o índice de massa corpórea em idosos
Efeitos do Pilates solo e exercício resistido sobre a obesidade central e o índice de massa corpórea em idosos
<!--[if gte mso 9]><xml> <w:WordDocument> <w:View>Normal</w:View> <w:Zoom>0</w:Zoom> <w:TrackMoves /> <w:TrackFormatting /> &l...
Harmonic suppressing control strategy for MMC–HVDC
Harmonic suppressing control strategy for MMC–HVDC
Modular multi‐level converter based high‐voltage direct current transmission (MMC–HVDC), which combines the high‐power capacity of conventional HVDC and the excellent dynamic perfo...
Hungarian neutral vowels: A microcomparison
Hungarian neutral vowels: A microcomparison
<!--[if gte mso 9]><xml> <o:OfficeDocumentSettings> <o:AllowPNG /> </o:OfficeDocumentSettings> </xml><![endif]--> <!--[if gte mso 9]>...
Latest Trends in Power Supply for Offshore Oil and Gas Industry
Latest Trends in Power Supply for Offshore Oil and Gas Industry
Abstract
Objective
Traditionally, over the decades majority of offshore oil and gas operating companies (OPCOs) have managed their electrical power de...
Analysis of Cutting Forces in Peripheral Milling under Varying Machining Conditions
Analysis of Cutting Forces in Peripheral Milling under Varying Machining Conditions
Normal
0
21
false
false
false
ES
X-NONE
X-NONE
MicrosoftInternetExplorer4
...

