PERHITUNGAN NILAI OVERALL EQUIPMENT EFFECTIVENESS PADA POMPA DISTRIBUSI KUBOTA DOUBLE SUCTION VOLUTE PUMP MODEL DV-L DI PT. ABC
View through CrossRef
Evaluation of machine performance is certainly very necessary to improve company production performance, one of which can be done by knowing the value of performance effectiveness using the Overall Equipment Effectiveness (OEE) calculation. This research was conducted on the Kubota Double Suction Volute Pump Model DV-L centrifugal pump at PT. ABC. The purpose of this study is to determine the Overall Equipment Effectiveness (OEE) value based on availability, performance and rate of quality factors. To compare the company OEE values obtained with the Overall Equipment Effectiveness World Class standard and proceed with identifying six big losses and knowing the root causes of OEE values using a causal diagram. Calculations obtained an Availability value of 99,07%, Performance of 91,53% and Quality of 100% and an average OEE of 90,68%. It is known that the OEE value is at the OEE standard >85%, but the performance value of the pump is still below the JIPM performance standard of >95% so that corrective action can be taken to increase the performance value of the effectiveness of the clean water distribution process using the Kubota Double Secton Volute centrifugal pump Pump Model DV-L.
Title: PERHITUNGAN NILAI OVERALL EQUIPMENT EFFECTIVENESS PADA POMPA DISTRIBUSI KUBOTA DOUBLE SUCTION VOLUTE PUMP MODEL DV-L DI PT. ABC
Description:
Evaluation of machine performance is certainly very necessary to improve company production performance, one of which can be done by knowing the value of performance effectiveness using the Overall Equipment Effectiveness (OEE) calculation.
This research was conducted on the Kubota Double Suction Volute Pump Model DV-L centrifugal pump at PT.
ABC.
The purpose of this study is to determine the Overall Equipment Effectiveness (OEE) value based on availability, performance and rate of quality factors.
To compare the company OEE values obtained with the Overall Equipment Effectiveness World Class standard and proceed with identifying six big losses and knowing the root causes of OEE values using a causal diagram.
Calculations obtained an Availability value of 99,07%, Performance of 91,53% and Quality of 100% and an average OEE of 90,68%.
It is known that the OEE value is at the OEE standard >85%, but the performance value of the pump is still below the JIPM performance standard of >95% so that corrective action can be taken to increase the performance value of the effectiveness of the clean water distribution process using the Kubota Double Secton Volute centrifugal pump Pump Model DV-L.
Related Results
Numerical Investigation on the Mechanism of Double-Volute Balancing Radial Hydraulic Force on the Centrifugal Pump
Numerical Investigation on the Mechanism of Double-Volute Balancing Radial Hydraulic Force on the Centrifugal Pump
Double-volute is an effective technique to reduce radial hydraulic force on the centrifugal pump and thereby mitigate the pump-casing vibration induced by unsteady flow characteris...
The Canberra Bubble
The Canberra Bubble
According to the ABC television program Four Corners, “Parliament House in Canberra is a hotbed of political intrigue and high tension … . It’s known as the ‘Canberra Bubble’ and i...
PRELIMINARY DESIGN OF RDE FEEDWATER PUMP IMPELLER
PRELIMINARY DESIGN OF RDE FEEDWATER PUMP IMPELLER
Nowadays, pumps are being widely used in the thermal power generation including nuclear power plants. Reaktor Daya Eksperimental (RDE) is a proposed nuclear reactor concept for the...
ANALISIS PERFORMA MAIN COOLING WATER PUMP PEMBANGKIT LISTRIK TENAGA PANAS BUMI (PLTP) PT.X
ANALISIS PERFORMA MAIN COOLING WATER PUMP PEMBANGKIT LISTRIK TENAGA PANAS BUMI (PLTP) PT.X
Pembangkit listrik tenaga panas bumi (PLTP) merupakan pembangkit listrik yang menggunakan energi terbarukan. Karena bahan utama yang digunakan untuk memutarkan turbin adalah uap ba...
Uji Fungsi Dan Karakterisasi Pompa Roda Gigi
Uji Fungsi Dan Karakterisasi Pompa Roda Gigi
Pompa roda gigi merupakan pompa perpindahan positif yang tergolong dalam<br />pompa rotari. Pompa roda gigi digunakan untuk memompa flida dengan viskositas tinggi dan<br /...
Evaluasi Corrective Maintenance Single Screw Pump di PT. XYZ
Evaluasi Corrective Maintenance Single Screw Pump di PT. XYZ
Pompa adalah suatu alat atau mesin yang digunakan untuk memindahkan cairan dari suatu tempat ke tempat yang lain melalui suatu media perpipaan dengan cara menambahkan energi pada c...
PENINGKATAN EFISIENSI ENERGI PADA UNIT SPAM PADALARANG PERUMDA AIR MINUM TIRTA RAHARJA KABUPATEN BANDUNG
PENINGKATAN EFISIENSI ENERGI PADA UNIT SPAM PADALARANG PERUMDA AIR MINUM TIRTA RAHARJA KABUPATEN BANDUNG
Pelayanan air minum Kecamatan Padalarang Kabupaten Bandung diselenggarakan oleh Perumda Air Minum Tirta Raharja menggunakan kombinasi sistem perpompaan. Penggunaan sistem perpompaa...
Vibro-Acoustic Optimization Study for the Volute Casing of a Centrifugal Fan
Vibro-Acoustic Optimization Study for the Volute Casing of a Centrifugal Fan
Concerning fan systems with an air pipe connecting air intake and a closed outlet, aerodynamic noise cannot be directly transmitted from the fan inlet and outlet to the outside. At...