Identification of the best topology of delta configured three phase induction generator for distributed generation through experimental investigations
View through CrossRef
Abstract
Research on Self –excited induction generator (SEIG) brings a lot of attentions in the last three decades as a promising solution in distributed generation systems with low cost investment. There are two important fixations to attend in the operation of SEIG based systems, a) excitation and b) voltage regulation. Many procedures are reported regarding selection of excitation capacitance in the literature, based on state-state analysis, dynamic modeling, empirical formulas and machine parameters which involve various levels of complexity in findings. Moreover, the voltage regulation is the main challenge in implementation of SEIG based isolated systems. To address this problem, many power electronic-based schemes are proposed in the literature and but these solutions have few demerits importantly that additional cost of equipment and troubles due to failure of protection schemes. In particular, the installation of SEIG takes place at small scale in kW range in remote/rural communities which should not face such shortcomings. Further in case of off-grid systems, the maximum loading is fixed based on connected rating of the generator. This paper presents the various methods to find excitation capacitance and illustrates an experimental investigation on different possible reactive power compensation methods of delta connected SEIG and aimed to identify a simple method for terminal voltage control without power electronics. In this experimental work, the prime-mover of the generator is a constant speed turbine, which is the emulation of a micro/pico hydro turbine. From the results, it is found that a simple delta connected excitation and delta configured reactive power compensation limits voltage regulation within ±6% while maintaining the frequency of ±1%, which make feasible of the operation successfully in remote electrification systems.
Walter de Gruyter GmbH
Title: Identification of the best topology of delta configured three phase induction generator for distributed generation through experimental investigations
Description:
Abstract
Research on Self –excited induction generator (SEIG) brings a lot of attentions in the last three decades as a promising solution in distributed generation systems with low cost investment.
There are two important fixations to attend in the operation of SEIG based systems, a) excitation and b) voltage regulation.
Many procedures are reported regarding selection of excitation capacitance in the literature, based on state-state analysis, dynamic modeling, empirical formulas and machine parameters which involve various levels of complexity in findings.
Moreover, the voltage regulation is the main challenge in implementation of SEIG based isolated systems.
To address this problem, many power electronic-based schemes are proposed in the literature and but these solutions have few demerits importantly that additional cost of equipment and troubles due to failure of protection schemes.
In particular, the installation of SEIG takes place at small scale in kW range in remote/rural communities which should not face such shortcomings.
Further in case of off-grid systems, the maximum loading is fixed based on connected rating of the generator.
This paper presents the various methods to find excitation capacitance and illustrates an experimental investigation on different possible reactive power compensation methods of delta connected SEIG and aimed to identify a simple method for terminal voltage control without power electronics.
In this experimental work, the prime-mover of the generator is a constant speed turbine, which is the emulation of a micro/pico hydro turbine.
From the results, it is found that a simple delta connected excitation and delta configured reactive power compensation limits voltage regulation within ±6% while maintaining the frequency of ±1%, which make feasible of the operation successfully in remote electrification systems.
Related Results
Delta-8-THC: Delta-9-THC’s nicer younger sibling?
Delta-8-THC: Delta-9-THC’s nicer younger sibling?
Abstract
Background
Products containing delta-8-THC became widely available in most of the USA following the 2018 Farm Bill and by late 2020 were co...
North Syrian Mortaria and Other Late Roman Personal and Utility Objects Bearing Inscriptions of Good Luck
North Syrian Mortaria and Other Late Roman Personal and Utility Objects Bearing Inscriptions of Good Luck
<span style="font-size: 11pt; color: black; font-family: 'Times New Roman','serif'">ΠΗΛΙΝΑ ΙΓ&Delta...
Outcomes Following Allogeneic Stem Cell Transplantation for AML in First Completion Remission Are Comparable between MRD Negative Patients and MRD Positive Patients Receiving Induction Only and Are Superior to MRD Positive Patients Receiving Induction and
Outcomes Following Allogeneic Stem Cell Transplantation for AML in First Completion Remission Are Comparable between MRD Negative Patients and MRD Positive Patients Receiving Induction Only and Are Superior to MRD Positive Patients Receiving Induction and
Background:
Data suggests that the presence of measurable residual disease (MRD) at the time of transplant for AML portends a poor prognosis. The timing of MRD asses...
Demographic characteristics of SARS-CoV-2 B.1.617.2 (Delta) variant infections in Indian population
Demographic characteristics of SARS-CoV-2 B.1.617.2 (Delta) variant infections in Indian population
Abstract
Importance
Higher risks of contracting infection, developing severe illness and mortality are known facts in aged and ...
Origin of sedimentary organic matter in Mahakam Delta, Borneo, Indonesia
Origin of sedimentary organic matter in Mahakam Delta, Borneo, Indonesia
The Mahakam Delta is located on the east coast of Kalimantan, the Indonesian portion of Borneo, about 50 kilometres south of the equator, and contains sediments of Miocene to Plioc...
Analisa Pengaruh Tegangan Harmonik Terhadap Regulasi Tegangan Eksitasi Generator Satu Fasa
Analisa Pengaruh Tegangan Harmonik Terhadap Regulasi Tegangan Eksitasi Generator Satu Fasa
Esensinya setiap generator listrik satu fasa maupun tiga fasa telah dilengkapi dengan sistem eksitasi. Sistem eksitasi generator ada tiga, yaitu sistem eksitasi statis, dinamis, da...
Pendayagunaan Energi Matahari sebagai Sumber Energi Listrik Alternatif Menggunakan Generator Termoelektrik
Pendayagunaan Energi Matahari sebagai Sumber Energi Listrik Alternatif Menggunakan Generator Termoelektrik
Abstrak
Energi surya adalah energi terbarukan yang potensinya besar untuk dimanfaatkan. Bentuk energi surya yang telah lama dimanfaatkan manusia adalah energi termalnya. Mulai dar...
Abstract 1630: Vitamin E delta-tocotrienol prevents azoxymethane-induced colon carcinogenesis progression in Fisher-344 rats
Abstract 1630: Vitamin E delta-tocotrienol prevents azoxymethane-induced colon carcinogenesis progression in Fisher-344 rats
Abstract
Background: Chemoprevention by bioactive food components has emerged as an alternative approach for the prevention of colorectal carcinogenesis. We have sho...