Javascript must be enabled to continue!
Effect of Angle of Turn on Loss Characteristics and Flow Rectification of Curve Diffuser
View through CrossRef
Curve diffuser is often used in HVAC and wind tunnel systems to provide pressure recovery and avoid excessive energy loss to the surrounding environment. Performance of curve diffuser is disturbed mainly by the presences of flow separation and secondary flow vortices occurred due to the effect of turning angle, in which scarce literature found. In this study, the effect of turning angle from 30° to 180° configured with an area ratio of 1.60 to 4.00 and inflow Reynolds number of 5.934x104 – 1.783x105 on loss characteristics and flow rectification of curve diffuser is investigated with optimum configuration is proposed. Performance of curve diffuser is evaluated in terms of pressure recovery and flow uniformity using ANSYS CFD equipped with validated Standard k-ɛ model (ske) and enhanced wall treatment of y+ = 1.2 - 1.7. Results show that performance of pressure recovery and flow uniformity decreases respectively by 85.71% and 45.84% as the angle of turn increases from 30° to 180°. Curve diffuser with minimum angle of turn 30o, optimum area ratio 2.16 and intermediate Rein 8.163x104 turns out to be the best configuration to provide pressure recovery of 0.399 and flow uniformity of 3.630 m/s.
Title: Effect of Angle of Turn on Loss Characteristics and Flow Rectification of Curve Diffuser
Description:
Curve diffuser is often used in HVAC and wind tunnel systems to provide pressure recovery and avoid excessive energy loss to the surrounding environment.
Performance of curve diffuser is disturbed mainly by the presences of flow separation and secondary flow vortices occurred due to the effect of turning angle, in which scarce literature found.
In this study, the effect of turning angle from 30° to 180° configured with an area ratio of 1.
60 to 4.
00 and inflow Reynolds number of 5.
934x104 – 1.
783x105 on loss characteristics and flow rectification of curve diffuser is investigated with optimum configuration is proposed.
Performance of curve diffuser is evaluated in terms of pressure recovery and flow uniformity using ANSYS CFD equipped with validated Standard k-ɛ model (ske) and enhanced wall treatment of y+ = 1.
2 - 1.
7.
Results show that performance of pressure recovery and flow uniformity decreases respectively by 85.
71% and 45.
84% as the angle of turn increases from 30° to 180°.
Curve diffuser with minimum angle of turn 30o, optimum area ratio 2.
16 and intermediate Rein 8.
163x104 turns out to be the best configuration to provide pressure recovery of 0.
399 and flow uniformity of 3.
630 m/s.
Related Results
Effect of Expansion Direction/Area Ratio on Loss Characteristics and Flow Rectification of Curve Diffuser
Effect of Expansion Direction/Area Ratio on Loss Characteristics and Flow Rectification of Curve Diffuser
Curve diffuser is frequently used in applications such as HVAC, wind- tunnel, gas turbine cycle, aircraft engine etc. as an adapter to join the conduits of different cross-sectiona...
Perancangan diffuser aromaterapi menggunakan metode quality function deployment
Perancangan diffuser aromaterapi menggunakan metode quality function deployment
Diffuser aromaterapi merupakan suatu alat yang bisa mengolah air dengan tetesan cairan aromaterapi. Diffuser aromaterapi dapat digunakan di berbagai tempat seperti ruang keluarga, ...
CFD investigation of flow through a centrifugal compressor diffuser with splitter blades
CFD investigation of flow through a centrifugal compressor diffuser with splitter blades
AbstractThe aerodynamic losses in centrifugal compressors are mainly associated with the separated flow on the suction sides of impeller and diffuser vanes. The overall performance...
Investigation on Clocking Effect of Diffuser in a Multi-Stage Centrifugal Pump
Investigation on Clocking Effect of Diffuser in a Multi-Stage Centrifugal Pump
Abstract
The clocking effect is an important phenomenon in the multi-stage Rotating machinery. In order to master the rules and mechanism of diffuser clocking effect on the...
The Application of PIV in the Study of Impeller-Diffuser Interaction in Centrifugal Fan: Part II — Impeller-Vaned Diffuser Interaction
The Application of PIV in the Study of Impeller-Diffuser Interaction in Centrifugal Fan: Part II — Impeller-Vaned Diffuser Interaction
Abstract
The real flow inside a turbomachinery passage is unsteady and strongly affected by wakes between stator and rotor. The aim of this study was to help our und...
Parameter Optimization of Combustor Dump Diffuser Based on RSM
Parameter Optimization of Combustor Dump Diffuser Based on RSM
Abstract
At present, dump diffuser is basically adopted in the combustion chamber of aeroengine. The total pressure loss in it may account for 30% or even higher in ...
Unsteady Pre-Stall Behavior in a Centrifugal Compressor With Vaned Diffuser
Unsteady Pre-Stall Behavior in a Centrifugal Compressor With Vaned Diffuser
Abstract
Unsteady pre-stall behavior in a centrifugal compressor with a vaned diffuser was investigated by experimental and numerical analysis. The pre-stall disturb...
Viscous Flow Computations for the Diffuser Section of a Large Water Tunnel
Viscous Flow Computations for the Diffuser Section of a Large Water Tunnel
A new research project, involving the construction of a modern, large, closed-circuit depressurised high-speed water tunnel to support the detailed hydroacoustic, hydrodynamic, cav...