Javascript must be enabled to continue!
Medical Robotic Bed to Prevent Pressure Sores
View through CrossRef
Patients who stay in bed for long periods are prone to pressure sores. Pressure sores cause multiple complications and prolong hospitalization. To prevent pressure sores, the patient’s lying position must be changed continuously so that excessive pressure on any body part does not last long. In this paper, we propose a novel robotic bed to prevent the formation of pressure sores. This robotic bed is composed of multiple segments that are driven independently by brushless direct current motors and that use body pressure information for feedback control. By controlling the movement of the segments on the top of the bed with a fuzzy controller, the patient’s body pressure is kept below the reference value. Moreover, a belt-type body pressure sensor is developed herein by using force-sensing resistor technology to measure the patient’s body pressure. A bed control system composed of the main controller, a teach pendant, motor controllers, and sensors was implemented. Through real experiments, the validity of the proposed robot bed was verified, and it was confirmed that the fuzzy closed-loop controller followed the reference body pressure commands well.
Title: Medical Robotic Bed to Prevent Pressure Sores
Description:
Patients who stay in bed for long periods are prone to pressure sores.
Pressure sores cause multiple complications and prolong hospitalization.
To prevent pressure sores, the patient’s lying position must be changed continuously so that excessive pressure on any body part does not last long.
In this paper, we propose a novel robotic bed to prevent the formation of pressure sores.
This robotic bed is composed of multiple segments that are driven independently by brushless direct current motors and that use body pressure information for feedback control.
By controlling the movement of the segments on the top of the bed with a fuzzy controller, the patient’s body pressure is kept below the reference value.
Moreover, a belt-type body pressure sensor is developed herein by using force-sensing resistor technology to measure the patient’s body pressure.
A bed control system composed of the main controller, a teach pendant, motor controllers, and sensors was implemented.
Through real experiments, the validity of the proposed robot bed was verified, and it was confirmed that the fuzzy closed-loop controller followed the reference body pressure commands well.
Related Results
Characteristics and clinical course of patients referred to the NST
Characteristics and clinical course of patients referred to the NST
Background and aimsThe nutrition support team (NST) comprises doctors, nutritionists, pharmacists, and nurses who provide intensive nutritional treatment designed for each patient ...
Evaluating the Cost for Robotic vs “Non-Robotic” Transhiatal Esophagectomy
Evaluating the Cost for Robotic vs “Non-Robotic” Transhiatal Esophagectomy
Introduction
This study was undertaken to analyze and compare the cost of robotic transhiatal esophagectomy (THE) to “non-robotic” THE (ie, “open” and laparosco...
How does bed load transport influence the longitudinal profile of reservoir sedimentation?
How does bed load transport influence the longitudinal profile of reservoir sedimentation?
The construction of the reservoir has destroyed the equilibrium of the natural river and promoted the siltation of a large amount of sediment in the reservoir. The longitudinal pro...
Major costs associated with pressure sores
Major costs associated with pressure sores
Cost drivers in the treatment of full-thickness pressure sores were identified from the literature, Medicare data tapes and interviews with health-care providers. The following wer...
Pressure sores among malnourished necropsied adults - preliminary data
Pressure sores among malnourished necropsied adults - preliminary data
Pressure sores are common among bedridden, elderly, or malnourished patients, and may occur in terminal ill patients because of impaired mobility, fecal or urinary incontinence, an...
Economic Evaluation of Maize (Zea mays L.) as Influenced by Soil Nutrient Availability and BenefitCost Ratio under the Malwa Region
Economic Evaluation of Maize (Zea mays L.) as Influenced by Soil Nutrient Availability and BenefitCost Ratio under the Malwa Region
The present investigation titled “Economic Evaluation of Maize (Zea mays L.) as Influenced by Soil Nutrient Availability and Benefit–Cost Ratio under the Malwa Region”. The present...
Implementation of a Robotic Surgical Program in Gynaecological Oncology and Comparison with Prior Laparoscopic Series
Implementation of a Robotic Surgical Program in Gynaecological Oncology and Comparison with Prior Laparoscopic Series
Background. Robotic surgery in gynaecological oncology is a rapidly developing field as it offers several technical advantages over conventional laparoscopy. An audit was performed...
Clinical efficacy evaluation of TiRobot-assisted minimally invasive treatment for calcaneal fractures based on enhanced recovery after surgery principles
Clinical efficacy evaluation of TiRobot-assisted minimally invasive treatment for calcaneal fractures based on enhanced recovery after surgery principles
BackgroundCalcaneal fractures were the most common hindfoot fractures, with most being intra-articular. Compared to fractures in other locations, calcaneal fractures had poorer pro...

