Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Challenges in personal and clinical dosimetry using Li2B4O7 and MgB4O7 as TLD and OSLD

View through CrossRef
Thermoluminescent (TLD) and optically stimulated luminescent dosimeters (OSLD) are essential in radiation dosimetry. Such dosimeters can be easily transported due to their small size and can be used in in vivo dosimetry and anthropomorphic simulations. In this work, the dosimetric properties of Li2B4O7 and MgB4O7 compounds were evaluated based on their response to the applied stimulus, whether thermal or optical. The linear dose response range of the luminescent signal, its fading, the lowest detectable dose, and reproducibility are important parameters in determining a good dosimeter for clinical and personal dosimetry. Therefore, the objective of this work was, based on studies performed by other authors on dosimetric characterizations of doped a codoped Li2B4O7 and MgB4O7, to point out those compounds with the greatest potential for applications in personal and clinical dosimetry using TL and OSL techniques. Considering the results described in other works, the materials that stood out for use in personal and clinical dosimetry were Li2B4O7:Cu and MgB4O7:Dy,Na. In several of the reported studies, no data related to LDD, fading and reproducibility of the luminescent signal of the investigated compounds were found. Therefore, there are many possibilities for investigations into these two types of compounds for the purpose of their use in personal and clinical dosimetry. Further studies will provide a broader scientific basis for choosing appropriate dosimetric materials for these applications.
Title: Challenges in personal and clinical dosimetry using Li2B4O7 and MgB4O7 as TLD and OSLD
Description:
Thermoluminescent (TLD) and optically stimulated luminescent dosimeters (OSLD) are essential in radiation dosimetry.
Such dosimeters can be easily transported due to their small size and can be used in in vivo dosimetry and anthropomorphic simulations.
In this work, the dosimetric properties of Li2B4O7 and MgB4O7 compounds were evaluated based on their response to the applied stimulus, whether thermal or optical.
The linear dose response range of the luminescent signal, its fading, the lowest detectable dose, and reproducibility are important parameters in determining a good dosimeter for clinical and personal dosimetry.
Therefore, the objective of this work was, based on studies performed by other authors on dosimetric characterizations of doped a codoped Li2B4O7 and MgB4O7, to point out those compounds with the greatest potential for applications in personal and clinical dosimetry using TL and OSL techniques.
Considering the results described in other works, the materials that stood out for use in personal and clinical dosimetry were Li2B4O7:Cu and MgB4O7:Dy,Na.
In several of the reported studies, no data related to LDD, fading and reproducibility of the luminescent signal of the investigated compounds were found.
Therefore, there are many possibilities for investigations into these two types of compounds for the purpose of their use in personal and clinical dosimetry.
Further studies will provide a broader scientific basis for choosing appropriate dosimetric materials for these applications.

Related Results

Thermoluminescence Dosimetry Technique for Radiation Detection Applications
Thermoluminescence Dosimetry Technique for Radiation Detection Applications
Due to the risk of radiation exposure, radiation dosimetry is performed regularly to ensure the occupational safety of personnel and radiation workers. Therefore, various dosimeter...
Effects of high ambient temperature on the accuracy of thermoluminescent dosimeters for environmental monitoring
Effects of high ambient temperature on the accuracy of thermoluminescent dosimeters for environmental monitoring
Thermoluminescence dosimeters (TLDs) are widely used for both personal and environmental dosimetry. TLDs should have high accuracy under different conditions. The TL signal can dro...
Lithium Tetraborate as a Neutron Scintillation Detector: A Review
Lithium Tetraborate as a Neutron Scintillation Detector: A Review
This review explores the potential implementation of lithium tetraborate (Li2B4O7) as a scintillator medium for neutron detection applications. Several characteristics required for...
Study of the Response and Calibration Procedures of LiF:Mg, Ti TLD-100 for the Dosimetry of Photon Beam
Study of the Response and Calibration Procedures of LiF:Mg, Ti TLD-100 for the Dosimetry of Photon Beam
To guarantee quality assurance and quality control of the received radiation dose and treatment level, Thermoluminescent Dosimeter (TLD) is frequently employed in personal control ...
Technologies for retrospective radiation dosimetry
Technologies for retrospective radiation dosimetry
Abstract Radiation dosimetry is an important task for assessing the biological damages created in human being due to ionising radiation exposure. Ionising radiation ...
Sensitised TLD-700 for Neutron-Gamma Ray Dosimetry at Radiation Protection Dose Levels
Sensitised TLD-700 for Neutron-Gamma Ray Dosimetry at Radiation Protection Dose Levels
Abstract Computerised glow curve deconvolution (CGCD) has been used to study the TL dose response and the relative intensity of the high temperature peaks in both...
VIBRATIONAL SPECRTA OF SINGLE CRYSTAL Li2B4O7
VIBRATIONAL SPECRTA OF SINGLE CRYSTAL Li2B4O7
Polarized Raman spectra of single crystal Li2B4O7 have been measured in the wavenum-ber shift range of 50-3000cm-1 at room temperature. The infrared absorption spectrum of Li2B4O7 ...

Back to Top