Javascript must be enabled to continue!
Accuracy of optimized Sirius ray-tracing method in intraocular lens power calculation
View through CrossRef
AIM: To evaluate the accuracy and predictability of ray tracing-assisted intraocular lens (IOL) calculation function in Sirius internal software and further improve the accuracy by optimizing the calculation of predicted lens position (PLP).
METHODS: This retrospective study recruited 52 eyes of 49 patients. All of the cases with cataract had undergone phacoemulsi?cation combined with IOL implantation. SRK-T, Haigis formula, and Sirius ray-tracing method were all used for each eye's IOL calculation. The mean absolute value of prediction error (prediction error=predicted refraction- postoperative refraction) was defined as mean absolute prediction error (MAPE) and was determined for each method. Calculation of PLP was optimized by effective lens position (ELP). Optimized PLP was entered to Sirius internal software again to verify whether the method was improved.
RESULTS: Compared with SRK-T and Haigis formulas, less accuracy was shown in Sirius ray-tracing method (P=0.001). The ELP of the IOL moved forward compared to PLP (P<0.001). The MAPE of the ELP-inputted Sirius ray-tracing method was reduced. ELP and PLP were well correlated. Taking ELP as y and PLP given by Sirius soft as x, a linear regression formula y=0.1637x+3.1741 was concluded (R²=0.1066, P=0.018). It was shown that the optimized Sirius ray-tracing method (optimized PLP entered), compared with SRK-T and Haigis formulas, worked with the same accuracy (P=0.038).
CONCLUSION: The original Sirius ray tracing method is not satisfactory enough. However, in normal eyes, the optimized Sirius ray-tracing method in IOL calculation was as accurate as SRK-T and Haigis formulas.
Press of International Journal of Ophthalmology (IJO Press)
Title: Accuracy of optimized Sirius ray-tracing method in intraocular lens power calculation
Description:
AIM: To evaluate the accuracy and predictability of ray tracing-assisted intraocular lens (IOL) calculation function in Sirius internal software and further improve the accuracy by optimizing the calculation of predicted lens position (PLP).
METHODS: This retrospective study recruited 52 eyes of 49 patients.
All of the cases with cataract had undergone phacoemulsi?cation combined with IOL implantation.
SRK-T, Haigis formula, and Sirius ray-tracing method were all used for each eye's IOL calculation.
The mean absolute value of prediction error (prediction error=predicted refraction- postoperative refraction) was defined as mean absolute prediction error (MAPE) and was determined for each method.
Calculation of PLP was optimized by effective lens position (ELP).
Optimized PLP was entered to Sirius internal software again to verify whether the method was improved.
RESULTS: Compared with SRK-T and Haigis formulas, less accuracy was shown in Sirius ray-tracing method (P=0.
001).
The ELP of the IOL moved forward compared to PLP (P<0.
001).
The MAPE of the ELP-inputted Sirius ray-tracing method was reduced.
ELP and PLP were well correlated.
Taking ELP as y and PLP given by Sirius soft as x, a linear regression formula y=0.
1637x+3.
1741 was concluded (R²=0.
1066, P=0.
018).
It was shown that the optimized Sirius ray-tracing method (optimized PLP entered), compared with SRK-T and Haigis formulas, worked with the same accuracy (P=0.
038).
CONCLUSION: The original Sirius ray tracing method is not satisfactory enough.
However, in normal eyes, the optimized Sirius ray-tracing method in IOL calculation was as accurate as SRK-T and Haigis formulas.
Related Results
Morphometric OCT parameters of the lens under accommodative stimulus. Report 1. Assessment of age-related changes
Morphometric OCT parameters of the lens under accommodative stimulus. Report 1. Assessment of age-related changes
Introduction. The structural approach to studying the mechanism of accommodation and its age-related changes focuses on analyzing morphometric parameters (size, shape, and position...
Effect of Fasting on Intraocular Pressure
Effect of Fasting on Intraocular Pressure
Purpose: To determine the effect of fasting on intraocular pressure in fasting individuals.
Study Design: Cross sectional observational study.
Place and Duration of S...
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Abstract
Background
Urrets-Zavalia syndrome is a condition that arises after eye surgery, often linked to increased intraocular pressure followin...
Principles and applications of pencil tracing
Principles and applications of pencil tracing
Pencil tracing, a new approach to ray tracing, is introduced for faster image synthesis with more physical fidelity. The paraxial approximation theory for efficiently tracing a pen...
The Effects of Different Shapes of Capsulorrhexis on Postoperative Refractive Outcomes and Effective Position of the Intraocular Lens in Cataract Surgery
The Effects of Different Shapes of Capsulorrhexis on Postoperative Refractive Outcomes and Effective Position of the Intraocular Lens in Cataract Surgery
Abstract
Background:To evaluate the effects of anterior capsular opening size on deviation from predicted refraction and the effective position of the intraocular lens (ELP...
Effect of pupil dilation on IOLMaster® measurements in Pakistani Eyes
Effect of pupil dilation on IOLMaster® measurements in Pakistani Eyes
Objective: To analyse the effect of pupil dilation on intraocular lens instrument IOLMaster 500 biometric measurements, and to determine the effect of these measurements on intraoc...
Thin X ray Lens Design And Simulation
Thin X ray Lens Design And Simulation
A proposal of thin sandwich mirror array lens for X-ray telescope Wolter type lens is discussed. We discussed a process of design, fabrication of this thin X-ray lens and conduc...
Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens
Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens
Analysis of lens changes in Marfan syndrome (MS), in addition to assessing the position of the lens itself, should include the possibility of examining its supporting and accommoda...