Javascript must be enabled to continue!
Flow-Based Dielectrophoretic Biosensor for Detection of Bacteriophage MS2 as a Foodborne Virus Surrogate
View through CrossRef
Norovirus, a foodborne pathogen, causes a significant economic and health burden globally. Although detection methods exist, they are expensive and non-field deployable. A flow-based dielectrophoretic biosensor was designed for the detection of foodborne pathogenic viruses and was tested using bacteriophage MS2 as a norovirus surrogate. The flow-based MS2 sensor comprises a concentrator and a detector. The concentrator is an interdigitated electrode array designed to impart dielectrophoretic effects to manipulate viral particles toward the detector in a fluidic channel. The detector is made of a silver electrode conjugated with anti-MS2 IgG to allow for antibody–antigen biorecognition events and is supplied with the electrical current for the purpose of measurement. Serially diluted MS2 suspensions were continuously injected into the fluidic channel at 0.1 mL/min. A cyclic voltammogram indicated that current measurements from single-walled carbon nanotube (SWCNT)-coated electrodes increased compared to uncoated electrodes. Additionally, a drop in the current measurements after antibody immobilization and MS2 capture was observed with the developed electrodes. Antibody immobilization at the biorecognition site provided greater current changes with the antibody-MS2 complexes vs. the assays without antibodies. The electric field applied to the fluidic channel at 10 Vpp and 1 MHz contributed to an increase in current changes in response to MS2 bound on the detector and was dependent on the MS2 concentrations in the sample. The developed biosensor was able to detect MS2 with a sensitivity of 102 PFU/mL within 15 min. Overall, this work demonstrates a proof of concept for a rapid and field-deployable strategy to detect foodborne pathogens.
Title: Flow-Based Dielectrophoretic Biosensor for Detection of Bacteriophage MS2 as a Foodborne Virus Surrogate
Description:
Norovirus, a foodborne pathogen, causes a significant economic and health burden globally.
Although detection methods exist, they are expensive and non-field deployable.
A flow-based dielectrophoretic biosensor was designed for the detection of foodborne pathogenic viruses and was tested using bacteriophage MS2 as a norovirus surrogate.
The flow-based MS2 sensor comprises a concentrator and a detector.
The concentrator is an interdigitated electrode array designed to impart dielectrophoretic effects to manipulate viral particles toward the detector in a fluidic channel.
The detector is made of a silver electrode conjugated with anti-MS2 IgG to allow for antibody–antigen biorecognition events and is supplied with the electrical current for the purpose of measurement.
Serially diluted MS2 suspensions were continuously injected into the fluidic channel at 0.
1 mL/min.
A cyclic voltammogram indicated that current measurements from single-walled carbon nanotube (SWCNT)-coated electrodes increased compared to uncoated electrodes.
Additionally, a drop in the current measurements after antibody immobilization and MS2 capture was observed with the developed electrodes.
Antibody immobilization at the biorecognition site provided greater current changes with the antibody-MS2 complexes vs.
the assays without antibodies.
The electric field applied to the fluidic channel at 10 Vpp and 1 MHz contributed to an increase in current changes in response to MS2 bound on the detector and was dependent on the MS2 concentrations in the sample.
The developed biosensor was able to detect MS2 with a sensitivity of 102 PFU/mL within 15 min.
Overall, this work demonstrates a proof of concept for a rapid and field-deployable strategy to detect foodborne pathogens.
Related Results
The Bacteriophage Efficiency and Antibiotics Susceptibility against Escherichia Coli and Staphylococcus Aureus
The Bacteriophage Efficiency and Antibiotics Susceptibility against Escherichia Coli and Staphylococcus Aureus
IntroductionThis study was held on the in vitro tests for the bacteriophages and their efficiency comparing with the antibiotics susceptibility in destroying bacteria. Because the ...
Analytical Formulation of the Electric Field Induced by Electrode Arrays: Towards Automated Dielectrophoretic Cell Sorting
Analytical Formulation of the Electric Field Induced by Electrode Arrays: Towards Automated Dielectrophoretic Cell Sorting
Dielectrophoresis is defined as the motion of an electrically polarisable particle in a non-uniform electric field. Current dielectrophoretic devices enabling sorting of cells are ...
Foodborne Disease Estimates for the United Kingdom in 2018
Foodborne Disease Estimates for the United Kingdom in 2018
In February 2020 the FSA published two reports which produced new estimates of foodborne norovirus cases. These were the ‘Norovirus Attribution Study’ (NoVAS study) (O’Brien et al....
An Assessment of the Efficacy of Commercial Air Ionizer Systems Against a SARS-CoV-2 Surrogate
An Assessment of the Efficacy of Commercial Air Ionizer Systems Against a SARS-CoV-2 Surrogate
Airborne transmission has been implicated as a major route for the spread of microorganisms, causing infectious disease outbreaks worldwide. This has been emphasized by the recent ...
Flow-enhanced detection of biological pathogens using piezoelectric microcantilever arrays
Flow-enhanced detection of biological pathogens using piezoelectric microcantilever arrays
The piezoelectric microcantilever sensor (PEMS) is an all-electrical resonant oscillator biosensor system capable of in-situ and label-free detection. Immobilized receptors on the ...
Cross-sectional survey of surrogate decision-making in Japanese medical practice
Cross-sectional survey of surrogate decision-making in Japanese medical practice
Abstract
Background
Instances of surrogate decision-making are expected to increase with the rise in hospitalised older adults in Japan. Few large-s...
Interactions Between Human Immunodeficiency Virus–1, Hepatitis Delta Virus and Hepatitis B Virus Infections in 260 Chronic Carriers of Hepatitis B Virus
Interactions Between Human Immunodeficiency Virus–1, Hepatitis Delta Virus and Hepatitis B Virus Infections in 260 Chronic Carriers of Hepatitis B Virus
To evaluate the factors determining the severity of chronic hepatitis B virus infection and the interactions of human immunodeficiency virus and hepatitis delta virus infections, w...

