Javascript must be enabled to continue!
Analytical Formulation of the Electric Field Induced by Electrode Arrays: Towards Automated Dielectrophoretic Cell Sorting
View through CrossRef
Dielectrophoresis is defined as the motion of an electrically polarisable particle in a non-uniform electric field. Current dielectrophoretic devices enabling sorting of cells are mostly controlled in open-loop applying a predefined voltage on micro-electrodes. Closed-loop control of these devices would enable to get advanced functionalities and also more robust behavior. Currently, the numerical models of dielectrophoretic force are too complex to be used in real-time closed-loop control. The aim of this paper is to propose a new type of models usable in this framework. We propose an analytical model of the electric field based on Fourier series to compute the dielectrophoretic force produced by parallel electrode arrays. Indeed, this method provides an analytical expression of the electric potential which decouples the geometrical factors (parameter of our system), the voltages applied on electrodes (input of our system), and the position of the cells (output of our system). Considering the Newton laws on each cell, it enables to generate easily a dynamic model of the cell positions (output) function of the voltages on electrodes (input). This dynamic model of our system is required to design the future closed-loop control law. The predicted dielectrophoretic forces are compared to a numerical simulation based on finite element model using COMSOL software. The model presented in this paper enables to compute the dielectrophoretic force applied to a cell by an electrode array in a few tenths of milliseconds. This model could be consequently used in future works for closed-loop control of dielectrophoretic devices.
Title: Analytical Formulation of the Electric Field Induced by Electrode Arrays: Towards Automated Dielectrophoretic Cell Sorting
Description:
Dielectrophoresis is defined as the motion of an electrically polarisable particle in a non-uniform electric field.
Current dielectrophoretic devices enabling sorting of cells are mostly controlled in open-loop applying a predefined voltage on micro-electrodes.
Closed-loop control of these devices would enable to get advanced functionalities and also more robust behavior.
Currently, the numerical models of dielectrophoretic force are too complex to be used in real-time closed-loop control.
The aim of this paper is to propose a new type of models usable in this framework.
We propose an analytical model of the electric field based on Fourier series to compute the dielectrophoretic force produced by parallel electrode arrays.
Indeed, this method provides an analytical expression of the electric potential which decouples the geometrical factors (parameter of our system), the voltages applied on electrodes (input of our system), and the position of the cells (output of our system).
Considering the Newton laws on each cell, it enables to generate easily a dynamic model of the cell positions (output) function of the voltages on electrodes (input).
This dynamic model of our system is required to design the future closed-loop control law.
The predicted dielectrophoretic forces are compared to a numerical simulation based on finite element model using COMSOL software.
The model presented in this paper enables to compute the dielectrophoretic force applied to a cell by an electrode array in a few tenths of milliseconds.
This model could be consequently used in future works for closed-loop control of dielectrophoretic devices.
Related Results
Boosting Oxygen Electrode Performance via a Redox-Treatment
Boosting Oxygen Electrode Performance via a Redox-Treatment
Introduction
The transition to a sustainable energy system complying with climate policy targets is a huge societal challenge. “Hard to electri...
Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract
Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...
Assessing Array-Type Differences in Cochlear Implant Users Using the Panoramic ECAP Method
Assessing Array-Type Differences in Cochlear Implant Users Using the Panoramic ECAP Method
OBJECTIVES: Cochlear-implant companies manufacture devices with different electrode array types. Some arrays have a straight geometry designed for minimal neuronal trauma, while ot...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Supercapacitive MnO2/PEDOT: PSS Modified 3D-Printed Polymeric Micro-Pillar Electrode for Extraction of Photosynthetic Electrons
Supercapacitive MnO2/PEDOT: PSS Modified 3D-Printed Polymeric Micro-Pillar Electrode for Extraction of Photosynthetic Electrons
Photosynthetic bio-electrochemical cells (PBECs) have been reported as having promising potential for the renewable energy field. When photosynthesis occurs, photosynthetic electro...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Percolation Investigation of Polymer-Based Battery Electrodes and Its Influence on Capacity Utilization
Percolation Investigation of Polymer-Based Battery Electrodes and Its Influence on Capacity Utilization
Our oral presentation will offer a comprehensive exploration of the intricate dynamics governing organic radical battery electrodes, focusing on the percolation phenomena and its c...
Field-emission current densities of carbon nanotube under the different electric fields
Field-emission current densities of carbon nanotube under the different electric fields
The field emission current variation law of carbon nanotube in a large electric field range (0-32 V m-1) is analyzed in depth by combining the density functional theory with metal ...

