Certain investigations on multi input –SEPIC-RE boost-system with enhanced-response

View through CrossRef
Recent developments in converters have given pathway to high-gain-step up converter having low output voltage ripple. High-gain-step up converters can be found between Photovoltaic Voltage (PV) and Direct-Current (D-C) loads. The intention of this work is to identify multi converter system for multiple input sources and to improve time response of high-gain-step up-converter. Closed-loop Multi-Converter System (MCS) is utilized to regulate load voltage. This effort recommends suitable-controller for “closed-loop-controlled-SEPIC-REBOOST Converter fed DC motor”. The estimation of the yield in ‘open-loop’&‘closed- loop-circuit’ has been done using MATLAB or Simulink. Closed-loop-control of MCS with PI and FOPID-Controllers are investigated and their responses are evaluated in conditions of rise time, peak time, settling time and steady state error. It is seen that FOPID controlled MCS gives better time domain response in terms of motor speed. A ‘Prototype of MCS’ has been fabricated in the laboratory& the ‘experimental-results’ are authenticated with the simulation-results.   
Title: Certain investigations on multi input –SEPIC-RE boost-system with enhanced-response
Description:
Recent developments in converters have given pathway to high-gain-step up converter having low output voltage ripple.
High-gain-step up converters can be found between Photovoltaic Voltage (PV) and Direct-Current (D-C) loads.
The intention of this work is to identify multi converter system for multiple input sources and to improve time response of high-gain-step up-converter.
Closed-loop Multi-Converter System (MCS) is utilized to regulate load voltage.
This effort recommends suitable-controller for “closed-loop-controlled-SEPIC-REBOOST Converter fed DC motor”.
The estimation of the yield in ‘open-loop’&‘closed- loop-circuit’ has been done using MATLAB or Simulink.
Closed-loop-control of MCS with PI and FOPID-Controllers are investigated and their responses are evaluated in conditions of rise time, peak time, settling time and steady state error.
It is seen that FOPID controlled MCS gives better time domain response in terms of motor speed.
A ‘Prototype of MCS’ has been fabricated in the laboratory& the ‘experimental-results’ are authenticated with the simulation-results.
   .

Related Results

[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED]Rhino XL Reviews, NY USA: Studies show that testosterone levels in males decrease constantly with growing age. There are also many other problems that males face due ...
SIMULATION OF CLOSED LOOP VOLTAGE CONTROL OF SEPIC CONVERTER
SIMULATION OF CLOSED LOOP VOLTAGE CONTROL OF SEPIC CONVERTER
In this study, a robust output SEPIC DC-DC converter is designed and simulated. The studied single ended primary inductor converter (SEPIC) output voltage is regulated to a constan...
Integration of FOPID and Mayfly Algorithm for SEPIC with Multi-objective Functions
Integration of FOPID and Mayfly Algorithm for SEPIC with Multi-objective Functions
Abstract SEPIC DC/DC with a single stage converter is organized in this work. Still, there is an energy loss of the single-ended primary-inductor converter (SEPIC), there i...
FOUR SWITCH THREE PHASE SEPIC INVERTER WITH FRONT END BOOST CONVERTER
FOUR SWITCH THREE PHASE SEPIC INVERTER WITH FRONT END BOOST CONVERTER
In this paper, four switch sepic inverter with front end boost converter capable of producing quality three phase ac output is explained. Proposed topology is an advanced one when ...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
SEPIC converter of Automatic Power Factor Correction by improved traditional linear control
SEPIC converter of Automatic Power Factor Correction by improved traditional linear control
With increasing using of nonlinear electronic equipment at a wide range, total harmonics distortion (THD) in the line current has grown to be a considerable problem. The methods th...
Power Factor Correction And Power Quality Improvement in BLDC Motor Drive Using Sepic Converter
Power Factor Correction And Power Quality Improvement in BLDC Motor Drive Using Sepic Converter
This project design SEPIC DC-DC converter feeding a BLDC motor drive as a cost effective solution for low power applications. In proposed circuit the single phase supply is fed to ...