Javascript must be enabled to continue!
X-Ray Inspection Study with Pcb Cavity Press-Fit Connectors
View through CrossRef
ABSTRACT
X-ray inspection on connectors becomes more and more important in these years as more connectors are mounted on PCBA due to their apparent benefits
1-2
. In this paper, we would like to share our studying experience for PCB Cavity Press-Fit connector on cavity PCB area. Our assembly with two press-fit connectors are inspected with the AXI, in order to make sure there is no broken pins enclosed inside the cavity, especially at the connector pins area.
We have been working with AXI3, AXI5 and AXI6, and looking for good solutions for the last year. AXI3 is normal AXI (Automated X-ray Inspection); AXI5 and AXI6 are special AXI machines which have CT (Computed tomography) capabilities. Both AXI5 and AXI6 have capabilities to detect broken pin in cavity connector pins area with very clear X-ray images, and pass/fail judgments are independent of their operator skills. However AXI5 and AXI6 testing times are longer than AXI3.
Finally we has developed good method to solve its issue at AXI after more than one year studying: the Algorithm and Threshold setting of AXI3 will be discussed in the paper. Recently AXI3 has capabilities to detect defect with PCB Cavity Press-Fit connector with very good balance between defects escaped percent and false call PPM. With joined studies and collaboration between Flextronics AXI team and AXI 3 R&D for eight months, outcome of the collaboration is very promising. Defects escaped rate has reduced from 20% to 0%, while false call PPM has reduced from >10,000 PPM to <500 PPM.
Surface Mount Technology Association
Title: X-Ray Inspection Study with Pcb Cavity Press-Fit Connectors
Description:
ABSTRACT
X-ray inspection on connectors becomes more and more important in these years as more connectors are mounted on PCBA due to their apparent benefits
1-2
.
In this paper, we would like to share our studying experience for PCB Cavity Press-Fit connector on cavity PCB area.
Our assembly with two press-fit connectors are inspected with the AXI, in order to make sure there is no broken pins enclosed inside the cavity, especially at the connector pins area.
We have been working with AXI3, AXI5 and AXI6, and looking for good solutions for the last year.
AXI3 is normal AXI (Automated X-ray Inspection); AXI5 and AXI6 are special AXI machines which have CT (Computed tomography) capabilities.
Both AXI5 and AXI6 have capabilities to detect broken pin in cavity connector pins area with very clear X-ray images, and pass/fail judgments are independent of their operator skills.
However AXI5 and AXI6 testing times are longer than AXI3.
Finally we has developed good method to solve its issue at AXI after more than one year studying: the Algorithm and Threshold setting of AXI3 will be discussed in the paper.
Recently AXI3 has capabilities to detect defect with PCB Cavity Press-Fit connector with very good balance between defects escaped percent and false call PPM.
With joined studies and collaboration between Flextronics AXI team and AXI 3 R&D for eight months, outcome of the collaboration is very promising.
Defects escaped rate has reduced from 20% to 0%, while false call PPM has reduced from >10,000 PPM to <500 PPM.
Related Results
Rancang Bangun Pembuat Layout PCB Otomatis Berbasis Android
Rancang Bangun Pembuat Layout PCB Otomatis Berbasis Android
ABSTRACT
The purpose of this research is to produce an Android-based automatic PCB layout path maker tool. This tool can automatically create a PCB layout path without etchin...
AXI Inspection Study with Heavily Shielded Press-Fit Connectors (IMPEL)
AXI Inspection Study with Heavily Shielded Press-Fit Connectors (IMPEL)
ABSTRACT
The demand for increased network bandwidth and advanced technology has led to the development on complex and high performance backplane/mid-plane connect...
Eyes on Air
Eyes on Air
Abstract
We at ADNOC Logistics & Services have identified the need for a Fully Integrated Inspection and Monitoring Solution to meet our operational, safety and ...
Electrical Connectors
Electrical Connectors
Abstract
Electrical connectors are mechanical devices that connect wires, cables, printed circuit boards, and electronic components to each other and to related equipment...
Fiber-cavity enhanced and high-fidelity optical memory in cold atom ensemble
Fiber-cavity enhanced and high-fidelity optical memory in cold atom ensemble
Entanglement between a photon and an atomic memory is an important tool for quantum repeater research. By using the Duan-Lukin-Cirac-Zoller (DLCZ) process in the atomic ensemble, q...
Machine Learning-Assisted Optimal Schedule of Underground Water Pipe Inspection
Machine Learning-Assisted Optimal Schedule of Underground Water Pipe Inspection
Abstract
There are over 2.2 million miles of underground water pipes serving the cities in the United States. Many are in poor conditions and deteriorate rapidly. Failures ...
Volatilization of extensively dechlorinated polychlorinated biphenyls from historically contaminated sediments
Volatilization of extensively dechlorinated polychlorinated biphenyls from historically contaminated sediments
Abstract
A study was conducted as a preliminary characterization of the ability of Aroclor® 1248 polychlorinated biphenyl (PCB)-contaminated sediments to volatilize ...
Paclitaxel-coated balloon catheter versus paclitaxel-eluting stent for the treatment of coronary in-stent restenosis: A GRADE-assessed systematic review and meta-analysis of randomized controlled trials
Paclitaxel-coated balloon catheter versus paclitaxel-eluting stent for the treatment of coronary in-stent restenosis: A GRADE-assessed systematic review and meta-analysis of randomized controlled trials
Background:
Paclitaxel is an antimicrotubular agent and is used to coat balloons and stents used in percutaneous coronary intervention. This study aims to provide a poo...