Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Lung function changes in divers after a single deep helium-oxygen dive

View through CrossRef
Introduction: This study measured pulmonary function in divers after a single helium-oxygen (heliox) dive to 80, 100, or 120 metres of sea water (msw). Methods: A total of 26 divers participated, of whom 15, five, and six performed a 80, 100, or 120 msw dive, respectively. While immersed, the divers breathed heliox and air, then oxygen during surface decompression in a hyperbaric chamber. Pulmonary function was measured twice before diving, 30 min after diving, and 24 h after diving. Results: At 30 min after the 80 msw dive the forced expiratory volume in 1 s (FEV1)/forced vital capacity (FVC) ratio and the maximum expiratory flow at 25% of vital capacity (MEF25) values decreased (89.2% to 87.1% and 2.57 L·s-1 to 2.35 L·s-1, P = 0.04, P = 0.048 respectively) but FEV1/FVC returned to the baseline values by 24 h post-dive. Other pulmonary indicators exhibited downward trends at 30 min after the dive, but statistical significance was lacking. Interestingly, though several parameters decreased after the 100 msw dive, statistical significance was not reached. After the 120 msw dive, the FEV1/FVC and MEF75 decreased (90.4% to 85.6% and 8.05 L·s-1 to 7.46 L·s-1, P = 0.01, P = 0.007). The relatively small numbers of subjects who dived to 100 and 120 msw depths may explain the inconsistent results. The subjects diving to 100 and 120 msw were more trained / skilled, but this would not explain the inconsistencies in results between these depths. Conclusions: We conclude that single deep heliox dives cause a temporary decrease in FEV1/FEV and MEF25 or MEF75, but these changes can recover at 24 h after the dive.
Title: Lung function changes in divers after a single deep helium-oxygen dive
Description:
Introduction: This study measured pulmonary function in divers after a single helium-oxygen (heliox) dive to 80, 100, or 120 metres of sea water (msw).
Methods: A total of 26 divers participated, of whom 15, five, and six performed a 80, 100, or 120 msw dive, respectively.
While immersed, the divers breathed heliox and air, then oxygen during surface decompression in a hyperbaric chamber.
Pulmonary function was measured twice before diving, 30 min after diving, and 24 h after diving.
Results: At 30 min after the 80 msw dive the forced expiratory volume in 1 s (FEV1)/forced vital capacity (FVC) ratio and the maximum expiratory flow at 25% of vital capacity (MEF25) values decreased (89.
2% to 87.
1% and 2.
57 L·s-1 to 2.
35 L·s-1, P = 0.
04, P = 0.
048 respectively) but FEV1/FVC returned to the baseline values by 24 h post-dive.
Other pulmonary indicators exhibited downward trends at 30 min after the dive, but statistical significance was lacking.
Interestingly, though several parameters decreased after the 100 msw dive, statistical significance was not reached.
After the 120 msw dive, the FEV1/FVC and MEF75 decreased (90.
4% to 85.
6% and 8.
05 L·s-1 to 7.
46 L·s-1, P = 0.
01, P = 0.
007).
The relatively small numbers of subjects who dived to 100 and 120 msw depths may explain the inconsistent results.
The subjects diving to 100 and 120 msw were more trained / skilled, but this would not explain the inconsistencies in results between these depths.
Conclusions: We conclude that single deep heliox dives cause a temporary decrease in FEV1/FEV and MEF25 or MEF75, but these changes can recover at 24 h after the dive.

Related Results

The principles of helium exploration
The principles of helium exploration
Commercial helium systems have been found to date as a serendipitous by-product of petroleum exploration. There are nevertheless significant differences in the source and migration...
Comportement de l’hélium implanté dans le carbure de bore B4C
Comportement de l’hélium implanté dans le carbure de bore B4C
Le carbure de bore B4C est une céramique couramment utilisée comme absorbant neutronique pour la régulation de la puissance des réacteurs nucléaires. Les réactions d’absorption neu...
First impressions: Use of the Azoth Systems O’Dive subclavian bubble monitor on a liveaboard dive vessel
First impressions: Use of the Azoth Systems O’Dive subclavian bubble monitor on a liveaboard dive vessel
Germonpré P, Van der Eecken P, Van Renterghem E, Germonpré F-L, Balestra C. First impressions: Use of the Azoth Systems O’Dive subclavian bubble monitor on a liveaboard dive vessel...
Underwater pulse oximetry reveals increased rate of arterial oxygen desaturation across repeated freedives to 11 metres of freshwater
Underwater pulse oximetry reveals increased rate of arterial oxygen desaturation across repeated freedives to 11 metres of freshwater
Introduction: Recreational freedivers typically perform repeated dives to moderate depths with short recovery intervals. According to freediving standards, these recovery intervals...
Helium Signatures of Natural Gas From the Dongpu Sag, Bohai Bay Basin, Eastern China
Helium Signatures of Natural Gas From the Dongpu Sag, Bohai Bay Basin, Eastern China
The Dongpu Sag is one of the important areas for oil and gas exploration in the Bohai Bay Basin, eastern China, and natural gas from different strata in the sag contain a certain a...
Time to Start Up: CT-Basted Radiomics in Children’s Lung Diseases
Time to Start Up: CT-Basted Radiomics in Children’s Lung Diseases
Radiomics is a new interdisciplinary field and a fusion product consisting by large data technology and medical image to aid diagnosis. Radiomics can gather information from differ...
High Concentration Oxygen and Hypercapnia in Respiratory Disease
High Concentration Oxygen and Hypercapnia in Respiratory Disease
<p>Oxygen-induced elevations in arterial carbon dioxide tension have been demonstrated in patients with chronic obstructive pulmonary disease (COPD), asthma, pneumonia, obesi...