Javascript must be enabled to continue!
Factors Affecting Assay of Myoglobin by Complement Fixation or Immunodiffusion
View through CrossRef
Abstract
Quantitative micro-scale complement-fixation and semiquantitative gel immunodiffusion assays for myoglobin have been evaluated experimentally and used to measure myoglobin in the sera of more than 1500 patients. We report certain problems, observations, and methodological improvements. Serum caused enhancement of precipitin lines in the immunodiffusion assay. In the complement-fixation assay, serum interfered both by enhancing or inhibiting complement fixation. Suggested modifications in the complement-fixation assay are: (a) routine threefold or greater dilution of serum with buffer and (b) use of serum-based rather than buffer-based calibration materials in preparing standard curves. Three cycles of freeze-thaw of serum or buffer decreased detectable myoglobin by 50-100%. We conclude that certain serum-related factors and freezethaw phenomena are important causes of error in immunological assays for myoglobin
Title: Factors Affecting Assay of Myoglobin by Complement Fixation or Immunodiffusion
Description:
Abstract
Quantitative micro-scale complement-fixation and semiquantitative gel immunodiffusion assays for myoglobin have been evaluated experimentally and used to measure myoglobin in the sera of more than 1500 patients.
We report certain problems, observations, and methodological improvements.
Serum caused enhancement of precipitin lines in the immunodiffusion assay.
In the complement-fixation assay, serum interfered both by enhancing or inhibiting complement fixation.
Suggested modifications in the complement-fixation assay are: (a) routine threefold or greater dilution of serum with buffer and (b) use of serum-based rather than buffer-based calibration materials in preparing standard curves.
Three cycles of freeze-thaw of serum or buffer decreased detectable myoglobin by 50-100%.
We conclude that certain serum-related factors and freezethaw phenomena are important causes of error in immunological assays for myoglobin.
Related Results
Serum Myoglobin After Cardiac Surgery Predicts Postoperative Cardiogenic Shock Requiring Mechanical Circulatory Support Within 14 Days
Serum Myoglobin After Cardiac Surgery Predicts Postoperative Cardiogenic Shock Requiring Mechanical Circulatory Support Within 14 Days
Background:
Cardiogenic shock requiring mechanical circulatory support is a life-threatening complication of cardiac surgery with cardiopulmonary bypass (CPB). ...
High Cut-Off Renal Replacement Therapy for Removal of Myoglobin in Severe Rhabdomyolysis and Acute Kidney Injury: A Case Series
High Cut-Off Renal Replacement Therapy for Removal of Myoglobin in Severe Rhabdomyolysis and Acute Kidney Injury: A Case Series
<b><i>Background/Aim:</i></b> Rhabdomyolysis is associated with the release of myoglobin into the circulation, promoting acute kidney injury (AKI). In sever...
Comparing 3 Different Techniques of Patella Fracture Fixation and Their Complications
Comparing 3 Different Techniques of Patella Fracture Fixation and Their Complications
Introduction: Patella fractures managed by fixation with metal implants often cause local soft tissue irritation and necessitate implant removal. An alternative is to utilize sutur...
A fast protein liquid chromatography method for purification of myoglobin from different species
A fast protein liquid chromatography method for purification of myoglobin from different species
The aim of this study is to describe a fast method for the purification of high-purity myoglobin for Mass Spectroscopy analyses and to use it as standard-grade material. A three-st...
PERMEABILITY OF MUSCLE CAPILLARIES TO EXOGENOUS MYOGLOBIN
PERMEABILITY OF MUSCLE CAPILLARIES TO EXOGENOUS MYOGLOBIN
Whale skeletal muscle myoglobin (mol wt 17,800; molecular dimensions 25 x 34 x 42 Å) was used as a probe molecule for the pore systems of muscle capillaries. Diaphragms of Wistar-...
Mechanisms of complement subversion in infection & cancer
Mechanisms of complement subversion in infection & cancer
Mécanismes de subversion du complément dans l'infection et le cancer
Le système du complément est un système de surveillance immunitaire activé par la reconnaissanc...
Lisfranc open reduction and internal fixation in an athletic population: screw versus suture button fixation
Lisfranc open reduction and internal fixation in an athletic population: screw versus suture button fixation
Background:
Primarily ligamentous Lisfranc injuries occur in athletic populations. Unstable Lisfranc injuries are treated with internal fixation or arthrodesis. Interna...
Groin hernia repair : evaluation of clinical impacts and interactions of mesh and mesh fixation
Groin hernia repair : evaluation of clinical impacts and interactions of mesh and mesh fixation
<p dir="ltr">AIMS</p><p dir="ltr">The project underlying this thesis aimed to identify and quantify relative risk differences in reoperation rate (Papers I and II...

