Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Dielectrophoretic Microfluidic Device for Separating Microparticles Based on Size with Sub-Micron Resolution

View through CrossRef
This article details the mathematical model of a microfluidic device aimed at separating any binary heterogeneous sample of microparticles into two homogeneous samples based on size with sub-micron resolution. The device consists of two sections, where the upstream section is dedicated to focusing of microparticles, while the downstream section is dedicated to separation of the focused stream of microparticles into two samples based on size. Each section has multiple planar electrodes of finite size protruding into the microchannel from the top and bottom of each sidewall; each top electrode aligns with a bottom electrode and they form a pair leading to multiple pairs of electrodes on each side. The focusing section subjects all microparticles to repulsive dielectrophoretic force, from each set of the electrodes, to focus them next to one of the sidewalls. This separation section pushes the big microparticles toward the interior, away from the wall, of the microchannel using repulsive dielectrophoretic force, while the small microparticles move unaffected to achieve the desired degree of separation. The operating frequency of the set of electrodes in the separation section is maintained equal to the cross-over frequency of the small microparticles. The working of the device is demonstrated by separating a heterogeneous mixture consisting of polystyrene microparticles of different size (radii of 2 and 2.25 μm) into two homogeneous samples. The mathematical model is used for parametric study, and the performance is quantified in terms of separation efficiency and separation purity; the parameters considered include applied electric voltages, electrode dimensions, outlet widths, number of electrodes, and volumetric flowrate. The separation efficiencies and separation purities for both microparticles are 100% for low volumetric flow rates, a large number of electrode pairs, large electrode dimensions, and high differences between voltages in both sections.
Title: Dielectrophoretic Microfluidic Device for Separating Microparticles Based on Size with Sub-Micron Resolution
Description:
This article details the mathematical model of a microfluidic device aimed at separating any binary heterogeneous sample of microparticles into two homogeneous samples based on size with sub-micron resolution.
The device consists of two sections, where the upstream section is dedicated to focusing of microparticles, while the downstream section is dedicated to separation of the focused stream of microparticles into two samples based on size.
Each section has multiple planar electrodes of finite size protruding into the microchannel from the top and bottom of each sidewall; each top electrode aligns with a bottom electrode and they form a pair leading to multiple pairs of electrodes on each side.
The focusing section subjects all microparticles to repulsive dielectrophoretic force, from each set of the electrodes, to focus them next to one of the sidewalls.
This separation section pushes the big microparticles toward the interior, away from the wall, of the microchannel using repulsive dielectrophoretic force, while the small microparticles move unaffected to achieve the desired degree of separation.
The operating frequency of the set of electrodes in the separation section is maintained equal to the cross-over frequency of the small microparticles.
The working of the device is demonstrated by separating a heterogeneous mixture consisting of polystyrene microparticles of different size (radii of 2 and 2.
25 μm) into two homogeneous samples.
The mathematical model is used for parametric study, and the performance is quantified in terms of separation efficiency and separation purity; the parameters considered include applied electric voltages, electrode dimensions, outlet widths, number of electrodes, and volumetric flowrate.
The separation efficiencies and separation purities for both microparticles are 100% for low volumetric flow rates, a large number of electrode pairs, large electrode dimensions, and high differences between voltages in both sections.

Related Results

On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
<span style="font-size:11pt"><span style="background:#f9f9f4"><span style="line-height:normal"><span style="font-family:Calibri,sans-serif"><b><spa...
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
<p><em><span style="font-size: 11.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-langua...
Analytical Formulation of the Electric Field Induced by Electrode Arrays: Towards Automated Dielectrophoretic Cell Sorting
Analytical Formulation of the Electric Field Induced by Electrode Arrays: Towards Automated Dielectrophoretic Cell Sorting
Dielectrophoresis is defined as the motion of an electrically polarisable particle in a non-uniform electric field. Current dielectrophoretic devices enabling sorting of cells are ...
Mechanical characterization of soft microparticles prepared by droplet microfluidics
Mechanical characterization of soft microparticles prepared by droplet microfluidics
AbstractDroplet microfluidics is one of the most promising approaches that allows preparation of microparticles with tailored structure and composition. Various functional micropar...
Protein compositions changes of circulating microparticles in patients with valvular heart disease and cardiac surgery
Protein compositions changes of circulating microparticles in patients with valvular heart disease and cardiac surgery
We previously demonstrated that circulating microparticles from patients with valvular heart disease (VHD) and cardiac surgery with cardiopulmonary bypass(CPB) impaired endothelial...
Abstract 2667: Platelet microparticles infiltrating solid tumors transfer miRNAs and modulate tumor angiogenesis and growth
Abstract 2667: Platelet microparticles infiltrating solid tumors transfer miRNAs and modulate tumor angiogenesis and growth
Abstract Platelet-derived microparticles are associated with enhancement of metastasis and poor cancer outcomes. Platelet microparticles can transfer platelet microR...
Even Star Decomposition of Complete Bipartite Graphs
Even Star Decomposition of Complete Bipartite Graphs
<p><span lang="EN-US"><span style="font-family: 宋体; font-size: medium;">A decomposition (</span><span><span style="font-family: 宋体; font-size: medi...
Drug-Loaded Pectin Microparticles Prepared by Emulsion-Solvent Evaporation
Drug-Loaded Pectin Microparticles Prepared by Emulsion-Solvent Evaporation
The aim of this study was to develop the pectin-based microparticles by emulsion-solvent evaporation technique. The effects of concentration and type of pectin and addition of glut...