Management of Keratoconus With Corneal Rigid Gas-Permeable Contact Lenses

View through CrossRef
Abstract: Vision correction using a corneal rigid gas-permeable contact lens, which is relatively safe, easy to replace, and economical, is still the basis of the management for keratoconus. For eyes with keratoconus, two fitting strategies have traditionally been used in Japan: apical touch fitting with spherical lenses and parallel fitting with multicurve lenses. These two techniques have different success rates depending on the type and severity of keratoconus. Therefore, it is important to classify eyes with keratoconus into four types according to the shape of the cornea and select the prescription techniques according to this classification. If the corneal GPs prescribed by these fitting methods cannot be used because of mechanical irritation to the corneal epithelium, the “piggyback lens system” is an effective option. Furthermore, proper lens care must be instructed to patients to prevent contact lens-related complications and maintain visual function. If these fittings and introductions can be performed properly, corneal GPs can safely provide effective and comfortable vision for many patients with keratoconus, even for those with severe keratoconus.
Title: Management of Keratoconus With Corneal Rigid Gas-Permeable Contact Lenses
Description:
Abstract: Vision correction using a corneal rigid gas-permeable contact lens, which is relatively safe, easy to replace, and economical, is still the basis of the management for keratoconus.
For eyes with keratoconus, two fitting strategies have traditionally been used in Japan: apical touch fitting with spherical lenses and parallel fitting with multicurve lenses.
These two techniques have different success rates depending on the type and severity of keratoconus.
Therefore, it is important to classify eyes with keratoconus into four types according to the shape of the cornea and select the prescription techniques according to this classification.
If the corneal GPs prescribed by these fitting methods cannot be used because of mechanical irritation to the corneal epithelium, the “piggyback lens system” is an effective option.
Furthermore, proper lens care must be instructed to patients to prevent contact lens-related complications and maintain visual function.
If these fittings and introductions can be performed properly, corneal GPs can safely provide effective and comfortable vision for many patients with keratoconus, even for those with severe keratoconus.

Related Results

Corneal Deformation Response in Patients With keratoconus and in Healthy Subjects
Corneal Deformation Response in Patients With keratoconus and in Healthy Subjects
Abstract Background To compare the corneal deformation response between patients with keratoconus and healthy subjects and to identify potential characteristics associated...
Keratoconus: Current perspectives
Keratoconus: Current perspectives
Keratoconus is a corneal thinning disorder in which the inferior paracentral cornea thins and protrudes forwards. The onset is usually during the second decade. Blurred vision and ...
Clinical comparison of two specialty soft lenses for Keratoconus
Clinical comparison of two specialty soft lenses for Keratoconus
(English) Due to advanced diagnostic instruments for detection of early-stage keratoconus (KC), and procedures that halt its progression such as corneal collagen cross-linking (CXL...
Effects of collagen cross-linking on corneal topographic characteristics in the patients with keratoconus
Effects of collagen cross-linking on corneal topographic characteristics in the patients with keratoconus
Background: Keratoconus is a bilateral, non-inflammatory, progressive disorder characterized by corneal thinning and protrusion, progressive myopia, and irregular astigmatism. Avai...
Asthma and Keratoconus: An analysis of the risk factors association with the severity of keratoconus
Asthma and Keratoconus: An analysis of the risk factors association with the severity of keratoconus
Abstract Background: A cross-sectional study was undertaken in Australia to explore a wide range of risk factors associated with keratoconus. A questionnaire addressing age...
Keratoconus Screening in Primary Eye Care – A General Overview
Keratoconus Screening in Primary Eye Care – A General Overview
Keratoconus early detection (screening) and diagnosis requires an in-deep corneal analysis with different techniques; slip lamp assessment, corneal topography and corneal tomograph...
A predictive model for early diagnosis of keratoconus
A predictive model for early diagnosis of keratoconus
Abstract Background: The diagnosis of keratoconus in the early stages of the disease is necessary to initiate an early treatment of keratoconus. Furthermore to avoid possib...