Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

How Much Does Filler Apparatus Influence Ease of Injection (and Hence, Potential Safety)?

View through CrossRef
Purpose: To document the relative contributions of intrinsic filler fluid dynamics versus delivery systems for ease of injection—specifically, to measure extrusion force variability across different syringes and needles (with the characterization of intrinsic rheological fluid properties vs. delivery apparatus contributions to ease of injection). Methods: Six different fillers were tested: Belotero balance (Bel), Juvederm Voluma XC (Vol), Revanesse Versa (Rev), Restylane Lyft (Res), Radiesse (Rad), and Teosyal RHA3 (RHA). Extrusion force was measured in Newtons (N) for each by testing using the provided injection apparatus (needle + syringe), and also by standardizing all fillers to the same syringe and then varying needle sizes (30-ga, 27-ga, 25-ga/1.5-inch, 25-ga/2-inch, and 22-ga). Five trials were conducted for each scenario, with comparison via t-test (2-tailed, unpaired, assuming unequal variance). Results: The following results were noted: (1) in order of least to highest extrusion force in box-provided syringe + needle at 0.2 ml volume, the following were noted: Vol < RHA = Bel (27-ga) < Bel (30-ga) < Rev < Res = Rad; (2) for each filler (except for Vol which was similar), the box-provided syringe involved greater extrusion force than the standardized syringe used in this study (each 1-cc, p < 0.05); (3) for 27-ga and 30-ga needles, after standardization of delivery syringe at 0.2 ml volume, a significant difference was noted (proportional to increasing resistance): Bel = Vol = RHA3 < Res < Rev < Rad (for needles of 30-ga [p < 0.05] and 27-ga [p < 0.01]); (4) for testing cannulas after standardization of syringes no reproducible order was noted with increasing resistance when using 25-ga/1.5-inch long, 25-ga/2-inch, and 22g/2-inch cannulae; and (5) confirming expectation (validating study technique), the extrusion force was significantly higher for smaller needles and longer needles. Conclusions: The delivery apparatus appeared to be the most influential contributor to filler injection extrusion force, with significant changes in ease of injection correlated to the filler’s intrinsic rheological properties, such as viscosity (when standardized to the same syringe for needles tested). Knowledge of such data could influence the injector’s ability to maximize patients’ safety and clinical results.
Title: How Much Does Filler Apparatus Influence Ease of Injection (and Hence, Potential Safety)?
Description:
Purpose: To document the relative contributions of intrinsic filler fluid dynamics versus delivery systems for ease of injection—specifically, to measure extrusion force variability across different syringes and needles (with the characterization of intrinsic rheological fluid properties vs.
delivery apparatus contributions to ease of injection).
Methods: Six different fillers were tested: Belotero balance (Bel), Juvederm Voluma XC (Vol), Revanesse Versa (Rev), Restylane Lyft (Res), Radiesse (Rad), and Teosyal RHA3 (RHA).
Extrusion force was measured in Newtons (N) for each by testing using the provided injection apparatus (needle + syringe), and also by standardizing all fillers to the same syringe and then varying needle sizes (30-ga, 27-ga, 25-ga/1.
5-inch, 25-ga/2-inch, and 22-ga).
Five trials were conducted for each scenario, with comparison via t-test (2-tailed, unpaired, assuming unequal variance).
Results: The following results were noted: (1) in order of least to highest extrusion force in box-provided syringe + needle at 0.
2 ml volume, the following were noted: Vol < RHA = Bel (27-ga) < Bel (30-ga) < Rev < Res = Rad; (2) for each filler (except for Vol which was similar), the box-provided syringe involved greater extrusion force than the standardized syringe used in this study (each 1-cc, p < 0.
05); (3) for 27-ga and 30-ga needles, after standardization of delivery syringe at 0.
2 ml volume, a significant difference was noted (proportional to increasing resistance): Bel = Vol = RHA3 < Res < Rev < Rad (for needles of 30-ga [p < 0.
05] and 27-ga [p < 0.
01]); (4) for testing cannulas after standardization of syringes no reproducible order was noted with increasing resistance when using 25-ga/1.
5-inch long, 25-ga/2-inch, and 22g/2-inch cannulae; and (5) confirming expectation (validating study technique), the extrusion force was significantly higher for smaller needles and longer needles.
Conclusions: The delivery apparatus appeared to be the most influential contributor to filler injection extrusion force, with significant changes in ease of injection correlated to the filler’s intrinsic rheological properties, such as viscosity (when standardized to the same syringe for needles tested).
Knowledge of such data could influence the injector’s ability to maximize patients’ safety and clinical results.

Related Results

Fundamental Aspects of Filler Distribution in Paper
Fundamental Aspects of Filler Distribution in Paper
An effective and simple method for sectioning paper was developed that enabled determination of the distribution of filler in a large number of papers. Attention was concentrated o...
Overview of Key Zonal Water Injection Technologies in China
Overview of Key Zonal Water Injection Technologies in China
Abstract Separated layer water injection is the important technology to realize the oilfield long-term high and stable yield. Through continuous researches and te...
The Burden of Road Traffic Injuries: A Global Perspective
The Burden of Road Traffic Injuries: A Global Perspective
Introduction     Road Traffic Injury (RTI) pose a significant health challenge. It represents the eighth leading cause of death globally, prompting the UN to designate 2011-2020 as...
PENGARUH BUBUK TALK SEBAGAI BAHAN FILLER PENGGANTI PADA CAMPURAN AC-WC
PENGARUH BUBUK TALK SEBAGAI BAHAN FILLER PENGGANTI PADA CAMPURAN AC-WC
The use of filler aims to improve the density of the filler and stability a mixed mass. Because of the importance of filler uses program needs to be done on a mixture of substitute...
Exploring the Utilization of PHC Pile Waste Concrete as Filler in Asphalt Mastics
Exploring the Utilization of PHC Pile Waste Concrete as Filler in Asphalt Mastics
Using solid waste to replace limestone filler in asphalt concrete can not only reduce the cost of road construction, but also improve the utilization rate of solid waste. In this s...
ANALISIS KARAKTERISTIK MARSHALL CAMPURAN AC-WC MENGGUNAKAN FILLER ABU BATU ZEOLIT
ANALISIS KARAKTERISTIK MARSHALL CAMPURAN AC-WC MENGGUNAKAN FILLER ABU BATU ZEOLIT
Materials that are often used as fillers in the AC-WC asphalt mixture are cement and stone ash, because these materials are often used so that supplies are increasingly expensive. ...
Optimal Injection Parameters for Enhancing Coalbed Methane Recovery: A Simulation Study from the Shizhuang Block, Qinshui Basin, China
Optimal Injection Parameters for Enhancing Coalbed Methane Recovery: A Simulation Study from the Shizhuang Block, Qinshui Basin, China
The injection of N2 into coal reservoir has great potential in improving recovery of coalbed methane (CBM). In this study, a numerical model was established based on the GEM compon...
Bio-Based White Eggshell as a Value-Added Filler in Poly(Lactic Acid) Composites
Bio-Based White Eggshell as a Value-Added Filler in Poly(Lactic Acid) Composites
Based on its positive environmental impact, poly(lactic acid) (PLA) has been a gradual substitute for synthetic plastics used in diverse applications. The use of industrial limesto...

Back to Top