Javascript must be enabled to continue!
Investigation of the Influence of Wetting Ability of the Sprayed Surface of the Heat Exchanger on the Process of Evaporative Cooling
View through CrossRef
Ensuring the required microclimate parameters is the most critical task in hot climates. In pig farms, air cooling is provided by means of steam-compression chillers or evaporative cooling, which is the simplest way to cool the air. The implementation of evaporative cooling depends largely on the interaction of the media involved in this process. This paper considers the process of interaction of cooling water with the surface of a cellular polycarbonate heat exchanger. A mathematical model describing the process of wetting the sprayed surface of the heat exchanger is obtained. The authors determined the theoretical water flow rate required to provide air cooling for a given operation mode. Experimental trials of a recuperative heat recovery unit with a heat exchanger made of cellular polycarbonate equipped with a water evaporative cooling system were carried out. The authors conducted a comparative assessment to evaluate the effectiveness of evaporative cooling in a heat recovery unit equipped with a polycarbonate heat exchanger versus panel evaporative systems using wetted paper pads at pig farms in the Vladimir and Tambov regions of Russia. The panel evaporative coolers provided a temperature reduction of 11.3 °C without any splashing effect. Under the same operating conditions, the heat recovery unit achieved an inlet air temperature reduction of 10.5 °C, accompanied by splashing. When the water flow rate supplied for evaporation was reduced until the splashing ceased, the cooling temperature drop decreased to 10.1 °C, which is 11% lower, compared with the paper pads. The study revealed characteristic operating modes for the unit that ensure effective air cooling, depending on the cooling water flow rate. Since the prevailing temperature during the system’s main operating time is significantly lower than the design temperature (the absolute temperature maximum), to achieve effective cooling of the supply air without splashing or excessive water waste, the cooling circuit water should circulate at a flow rate within 40 to 63% of the maximum design value. Alternatively, an automated control system should be employed to regulate the water supply based on outdoor air temperature and humidity.
Title: Investigation of the Influence of Wetting Ability of the Sprayed Surface of the Heat Exchanger on the Process of Evaporative Cooling
Description:
Ensuring the required microclimate parameters is the most critical task in hot climates.
In pig farms, air cooling is provided by means of steam-compression chillers or evaporative cooling, which is the simplest way to cool the air.
The implementation of evaporative cooling depends largely on the interaction of the media involved in this process.
This paper considers the process of interaction of cooling water with the surface of a cellular polycarbonate heat exchanger.
A mathematical model describing the process of wetting the sprayed surface of the heat exchanger is obtained.
The authors determined the theoretical water flow rate required to provide air cooling for a given operation mode.
Experimental trials of a recuperative heat recovery unit with a heat exchanger made of cellular polycarbonate equipped with a water evaporative cooling system were carried out.
The authors conducted a comparative assessment to evaluate the effectiveness of evaporative cooling in a heat recovery unit equipped with a polycarbonate heat exchanger versus panel evaporative systems using wetted paper pads at pig farms in the Vladimir and Tambov regions of Russia.
The panel evaporative coolers provided a temperature reduction of 11.
3 °C without any splashing effect.
Under the same operating conditions, the heat recovery unit achieved an inlet air temperature reduction of 10.
5 °C, accompanied by splashing.
When the water flow rate supplied for evaporation was reduced until the splashing ceased, the cooling temperature drop decreased to 10.
1 °C, which is 11% lower, compared with the paper pads.
The study revealed characteristic operating modes for the unit that ensure effective air cooling, depending on the cooling water flow rate.
Since the prevailing temperature during the system’s main operating time is significantly lower than the design temperature (the absolute temperature maximum), to achieve effective cooling of the supply air without splashing or excessive water waste, the cooling circuit water should circulate at a flow rate within 40 to 63% of the maximum design value.
Alternatively, an automated control system should be employed to regulate the water supply based on outdoor air temperature and humidity.
Related Results
Investigation of the Influence of Wetting Ability of the Sprayed Surface of the Heat Exchanger on the Process of Water-Evaporative Cooling
Investigation of the Influence of Wetting Ability of the Sprayed Surface of the Heat Exchanger on the Process of Water-Evaporative Cooling
Ensuring the required microclimate parameters is the most critical task in hot climates. In pig farms, air cooling is provided by means of steam-compression chillers or water-evapo...
Theoretical Analysis of Geometrically Modified Dew Point Evaporative Cooler
Theoretical Analysis of Geometrically Modified Dew Point Evaporative Cooler
Abstract
Human thermal comfort being one of major aspect of increasing demand of energy consumption for heating, ventilation and air conditioning (HVAC) sector. The ...
Design and Study of Domestic Cooling System through Roof Ventilation Assisted by Evaporative Cooling
Design and Study of Domestic Cooling System through Roof Ventilation Assisted by Evaporative Cooling
This study shows the evaluation of the indirect evaporative cooling system beneath the roof that aims to reduce the cooling load in buildings. As the energy demand for space coolin...
Intrinsic Evaporative Cooling by Hygroscopic Earth Materials
Intrinsic Evaporative Cooling by Hygroscopic Earth Materials
The phase change of water from liquid to vapor is one of the most energy-intensive physical processes in nature, giving it immense potential for cooling. Diverse evaporative coolin...
Numerical Investigation of Power Generation Enhancement for Exhaust Heat Exchanger with Cylindrical Grooves in Thermoelectric Generator Systems
Numerical Investigation of Power Generation Enhancement for Exhaust Heat Exchanger with Cylindrical Grooves in Thermoelectric Generator Systems
<div class="section abstract"><div class="htmlview paragraph">For vehicle thermoelectric generator, heat would be directly transferred into electricity by thermoelectri...
EXPERIMENTAL STUDIES OF THE AIR HEAT EXCHANGER OF THE SIDE-EVAPORATION TYPE
EXPERIMENTAL STUDIES OF THE AIR HEAT EXCHANGER OF THE SIDE-EVAPORATION TYPE
Over the past two decades, many new devices based on renewable energy have been introduced for heating purposes: new heat recovery units, heat pumps, solar systems and many others
...
Analisis Kinerja Exhaust Gas Heat Exchanger Dengan Menggunakan Diagram Pareto
Analisis Kinerja Exhaust Gas Heat Exchanger Dengan Menggunakan Diagram Pareto
Heat Exchanger sebagai alat penukar kalor yang berfungsi untuk mengubah temperatur dan fasa suatu jenis fluida. Dalam penerapan heat exchanger terdapat permasalahan yang masih munc...
Comparing the Contributions of Cutaneous and Respiratory Evaporative Water Loss to Cooling in Anna’s Hummingbirds (Calypte anna) Under Fasted and Fed Conditions
Comparing the Contributions of Cutaneous and Respiratory Evaporative Water Loss to Cooling in Anna’s Hummingbirds (Calypte anna) Under Fasted and Fed Conditions
During high-temperature periods, endothermic animals evaporate water from the body surface to cool down. The two primary routes of evaporative water loss are: (1) evaporating water...