Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Investigation of the Influence of Wetting Ability of the Sprayed Surface of the Heat Exchanger on the Process of Evaporative Cooling

View through CrossRef
Ensuring the required microclimate parameters is the most critical task in hot climates. In pig farms, air cooling is provided by means of steam-compression chillers or evaporative cooling, which is the simplest way to cool the air. The implementation of evaporative cooling depends largely on the interaction of the media involved in this process. This paper considers the process of interaction of cooling water with the surface of a cellular polycarbonate heat exchanger. A mathematical model describing the process of wetting the sprayed surface of the heat exchanger is obtained. The authors determined the theoretical water flow rate required to provide air cooling for a given operation mode. Experimental trials of a recuperative heat recovery unit with a heat exchanger made of cellular polycarbonate equipped with a water evaporative cooling system were carried out. The authors conducted a comparative assessment to evaluate the effectiveness of evaporative cooling in a heat recovery unit equipped with a polycarbonate heat exchanger versus panel evaporative systems using wetted paper pads at pig farms in the Vladimir and Tambov regions of Russia. The panel evaporative coolers provided a temperature reduction of 11.3 °C without any splashing effect. Under the same operating conditions, the heat recovery unit achieved an inlet air temperature reduction of 10.5 °C, accompanied by splashing. When the water flow rate supplied for evaporation was reduced until the splashing ceased, the cooling temperature drop decreased to 10.1 °C, which is 11% lower, compared with the paper pads. The study revealed characteristic operating modes for the unit that ensure effective air cooling, depending on the cooling water flow rate. Since the prevailing temperature during the system’s main operating time is significantly lower than the design temperature (the absolute temperature maximum), to achieve effective cooling of the supply air without splashing or excessive water waste, the cooling circuit water should circulate at a flow rate within 40 to 63% of the maximum design value. Alternatively, an automated control system should be employed to regulate the water supply based on outdoor air temperature and humidity.
Title: Investigation of the Influence of Wetting Ability of the Sprayed Surface of the Heat Exchanger on the Process of Evaporative Cooling
Description:
Ensuring the required microclimate parameters is the most critical task in hot climates.
In pig farms, air cooling is provided by means of steam-compression chillers or evaporative cooling, which is the simplest way to cool the air.
The implementation of evaporative cooling depends largely on the interaction of the media involved in this process.
This paper considers the process of interaction of cooling water with the surface of a cellular polycarbonate heat exchanger.
A mathematical model describing the process of wetting the sprayed surface of the heat exchanger is obtained.
The authors determined the theoretical water flow rate required to provide air cooling for a given operation mode.
Experimental trials of a recuperative heat recovery unit with a heat exchanger made of cellular polycarbonate equipped with a water evaporative cooling system were carried out.
The authors conducted a comparative assessment to evaluate the effectiveness of evaporative cooling in a heat recovery unit equipped with a polycarbonate heat exchanger versus panel evaporative systems using wetted paper pads at pig farms in the Vladimir and Tambov regions of Russia.
The panel evaporative coolers provided a temperature reduction of 11.
3 °C without any splashing effect.
Under the same operating conditions, the heat recovery unit achieved an inlet air temperature reduction of 10.
5 °C, accompanied by splashing.
When the water flow rate supplied for evaporation was reduced until the splashing ceased, the cooling temperature drop decreased to 10.
1 °C, which is 11% lower, compared with the paper pads.
The study revealed characteristic operating modes for the unit that ensure effective air cooling, depending on the cooling water flow rate.
Since the prevailing temperature during the system’s main operating time is significantly lower than the design temperature (the absolute temperature maximum), to achieve effective cooling of the supply air without splashing or excessive water waste, the cooling circuit water should circulate at a flow rate within 40 to 63% of the maximum design value.
Alternatively, an automated control system should be employed to regulate the water supply based on outdoor air temperature and humidity.

Related Results

Investigation of the Influence of Wetting Ability of the Sprayed Surface of the Heat Exchanger on the Process of Water-Evaporative Cooling
Investigation of the Influence of Wetting Ability of the Sprayed Surface of the Heat Exchanger on the Process of Water-Evaporative Cooling
Ensuring the required microclimate parameters is the most critical task in hot climates. In pig farms, air cooling is provided by means of steam-compression chillers or water-evapo...
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Abstract This paper presents the design and cost optimization of a novel 2MWth 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that i...
Performance Analysis of Direct Stage, In-Direct Stage and Two-Stage Evaporative Air Cooler
Performance Analysis of Direct Stage, In-Direct Stage and Two-Stage Evaporative Air Cooler
Evaporative coolers are used in various areas especially in dry, hot climates in weather. This research focus on the theoretical and experimental result of the evaporative air cool...
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Abstrak Heat exchanger atau alat penukar panas adalah alat-alat yang digunakan untuk mengubah temperatur fluida atau mengubah fasa fluida dengan cara mempertukarkan panasnya dengan...
A New Mathematical Model for EOR Displacements Honouring Oil Ganglia
A New Mathematical Model for EOR Displacements Honouring Oil Ganglia
Abstract During two-phase flow in porous media non-wetting phase is present simultaneously in states of mobile connected continuum and of trapped isolated ganglia...
Evaporative Cooling Systems for Perishables in Sub‐Saharan Africa—A Review
Evaporative Cooling Systems for Perishables in Sub‐Saharan Africa—A Review
ABSTRACTPostharvest food losses in the supply chain are currently estimated at 20% in the Sub‐Saharan Africa region. In Sub‐Saharan Africa, where the loss of fruits and vegetables ...
Theoretical Analysis of Geometrically Modified Dew Point Evaporative Cooler
Theoretical Analysis of Geometrically Modified Dew Point Evaporative Cooler
Abstract Human thermal comfort being one of major aspect of increasing demand of energy consumption for heating, ventilation and air conditioning (HVAC) sector. The ...
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Abstract In Large Gas Turbines, turbine components in particular blades and vanes operate at significantly high temperatures. As a result, cooling of these component...

Back to Top