Analysis of Current Carrying Capacity of Power Cable Based on DTS

View through CrossRef
Abstract This article uses a distributed optical fiber temperature measurement system (DTS, Distributed Temperature Sensing) to fix the temperature measurement optical fiber on the surface of the power cable, collect the real-time operating temperature of the power cable, conduct the ampacity test, and analyze the cable laying method and depth, soil temperature, Soil thermal resistance coefficient, cable spacing and irradiation strength and other test conditions, the impact on the current carrying capacity of power cables. According to the real-time monitoring temperature of the cable, the alarm can be made when the cable temperature is too high or the temperature rise speed is too fast. And on the basis of determining the working temperature and load operating conditions of the cable conductor core, dynamically calculate the current carrying capacity of the cable, which is conducive to improving the performance of the power cable and increasing the load capacity of the power cable.
Title: Analysis of Current Carrying Capacity of Power Cable Based on DTS
Description:
Abstract This article uses a distributed optical fiber temperature measurement system (DTS, Distributed Temperature Sensing) to fix the temperature measurement optical fiber on the surface of the power cable, collect the real-time operating temperature of the power cable, conduct the ampacity test, and analyze the cable laying method and depth, soil temperature, Soil thermal resistance coefficient, cable spacing and irradiation strength and other test conditions, the impact on the current carrying capacity of power cables.
According to the real-time monitoring temperature of the cable, the alarm can be made when the cable temperature is too high or the temperature rise speed is too fast.
And on the basis of determining the working temperature and load operating conditions of the cable conductor core, dynamically calculate the current carrying capacity of the cable, which is conducive to improving the performance of the power cable and increasing the load capacity of the power cable.

Related Results

Study on the Ecological Carrying Capacity and Driving Factors of the Source Region of the Yellow River in China in the Past 30 Years
Study on the Ecological Carrying Capacity and Driving Factors of the Source Region of the Yellow River in China in the Past 30 Years
Abstract Under the influence of natural factors and human activities, the ecological environment functions in the source region of the Yellow River in China have been degra...
Deep Learning Training Model Construction and Optimization of Cable Size Features in 3D Point Cloud Data
Deep Learning Training Model Construction and Optimization of Cable Size Features in 3D Point Cloud Data
Cables are widely used in power transmission, and the measurement of key dimensions of cables is an indispensable part of the cable preparation process to help ensure their quality...
Prevalence and distribution of sesamoid bones and accessory ossicles of the foot as determined by digital tomosynthesis
Prevalence and distribution of sesamoid bones and accessory ossicles of the foot as determined by digital tomosynthesis
We previously reported that digital tomosynthesis (DTS) is a reliable tool for evaluating bony structures of the hand. The current study aimed to identify the prevalence and distri...
Analysis of grassland carrying capacity in Inner Mongolia based on ecosystem function
Analysis of grassland carrying capacity in Inner Mongolia based on ecosystem function
<p>With the increase of global temperature and the intensification of human activities, numerous ecological problems have occurred in the grasslands of Inner Mongolia...
Cable Steady-State Ampacity Correction Method based on Multi Physical Field Coupling Algorithm
Cable Steady-State Ampacity Correction Method based on Multi Physical Field Coupling Algorithm
The difference between the single air laying ampacity test value of medium voltage power cable and the system ampacity of three-phase laying and operation is a common problem in th...
Global Dynamics of a Hang-Off Power Cable Immersed in the Flow Near a Fixed Offshore Wind Turbine
Global Dynamics of a Hang-Off Power Cable Immersed in the Flow Near a Fixed Offshore Wind Turbine
Abstract The hang-off power cable extending from the offshore wind turbine tower takes the significant responsibility of electric energy transportation. The scour, t...
INFLUENCE OF THE AMBIENT TEMPERATURE ON THE MECHANICAL TENSION OF THE OPTICAL CABLE
INFLUENCE OF THE AMBIENT TEMPERATURE ON THE MECHANICAL TENSION OF THE OPTICAL CABLE
To ensure the quality and reliability of the fiber-optic communication line during the exploitation, it is necessary to constantly monitor the technical condition of the optical ca...
The life cycle of cable bacteria
The life cycle of cable bacteria
Cable bacteria are multicellular filamentous microorganisms that perform electrogenic sulphur oxidation, coupling the oxidation of sulphide in deeper sediments to oxygen reduction ...

Back to Top