Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Cable Steady-State Ampacity Correction Method based on Multi Physical Field Coupling Algorithm

View through CrossRef
The difference between the single air laying ampacity test value of medium voltage power cable and the system ampacity of three-phase laying and operation is a common problem in the industry. Based on the TICW-2012 standard, the single cable ampacity of medium voltage single core power cable is tested, and the COMSOL basic simulation model is debugged with the measured ampacity value. On the premise of correct single cable basic simulation model, the system ampacity under three-phase operation under different working conditions is calculated, including triangular laying, plane laying, single circuit and double circuit laying, The difference and correction coefficient between the test current carrying capacity and the of single air laying of medium voltage single core power cable are further analysed. Finally, the analytical formula is derived through the cable ampacity equivalent thermal circuit diagram, and the cable samples are theoretically analysed and calculated. According to the ampacity calculation results of single loop triangular laying and plane laying, the correctness of the simulation results is verified. This study provides a reference basis for the current carrying capacity test and correction of medium voltage power cable in the future, and also provides an effective method for the actual operation state analysis of medium voltage power cable.
Title: Cable Steady-State Ampacity Correction Method based on Multi Physical Field Coupling Algorithm
Description:
The difference between the single air laying ampacity test value of medium voltage power cable and the system ampacity of three-phase laying and operation is a common problem in the industry.
Based on the TICW-2012 standard, the single cable ampacity of medium voltage single core power cable is tested, and the COMSOL basic simulation model is debugged with the measured ampacity value.
On the premise of correct single cable basic simulation model, the system ampacity under three-phase operation under different working conditions is calculated, including triangular laying, plane laying, single circuit and double circuit laying, The difference and correction coefficient between the test current carrying capacity and the of single air laying of medium voltage single core power cable are further analysed.
Finally, the analytical formula is derived through the cable ampacity equivalent thermal circuit diagram, and the cable samples are theoretically analysed and calculated.
According to the ampacity calculation results of single loop triangular laying and plane laying, the correctness of the simulation results is verified.
This study provides a reference basis for the current carrying capacity test and correction of medium voltage power cable in the future, and also provides an effective method for the actual operation state analysis of medium voltage power cable.

Related Results

Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
Ampacity of power cables exposed to solar radiation – recommendations of standards vs. CFD simulations
Ampacity of power cables exposed to solar radiation – recommendations of standards vs. CFD simulations
Ampacity of power cables strictly depends on the ambient conditions. It is very important whether a cable is buried in soil, installed in the air or placed in ducts. When a cable i...
Deep Learning Training Model Construction and Optimization of Cable Size Features in 3D Point Cloud Data
Deep Learning Training Model Construction and Optimization of Cable Size Features in 3D Point Cloud Data
Cables are widely used in power transmission, and the measurement of key dimensions of cables is an indispensable part of the cable preparation process to help ensure their quality...
Natural vibration and wind-induced response analysis of the non-fully symmetric Geiger cable dome
Natural vibration and wind-induced response analysis of the non-fully symmetric Geiger cable dome
Cable dome is a special flexible structure made of cable strut beam and membrane. Non-fully symmetric Geiger cable dome is a new Geiger cable dome with the characteristics of eight...
Wireline Cable Dynamics and Wellbore Diagnostics in the Deepwater Logging Environment
Wireline Cable Dynamics and Wellbore Diagnostics in the Deepwater Logging Environment
The evolving complexity of deepwater wellbores has created new challenges and risks for wireline evaluation. Geometries and depths challenge the foundational assumptions of traditi...
Analysis of Current Carrying Capacity of Power Cable Based on DTS
Analysis of Current Carrying Capacity of Power Cable Based on DTS
Abstract This article uses a distributed optical fiber temperature measurement system (DTS, Distributed Temperature Sensing) to fix the temperature measurement optic...
The life cycle of cable bacteria
The life cycle of cable bacteria
Cable bacteria are multicellular filamentous microorganisms that perform electrogenic sulphur oxidation, coupling the oxidation of sulphide in deeper sediments to oxygen reduction ...

Back to Top