Mechanically Induced Periprosthetic Osteolysis: A Systematic Review
View through CrossRef
Background
Peri-prosthetic bone loss can result from chemical, biological, and mechanical factors. Mechanical stimulation via fluid pressure and flow at the bone–implant interface may be a significant cause. Evidence supporting mechanically induced osteolysis continues to grow, but there is no synthesis of published clinical and basic science data.
Questions/Purposes
We sought to review the literature on two questions: (1) What published evidence supports the concept of mechanically induced osteolysis? (2) What is the proposed mechanism of mechanically induced osteolysis, and does it differ from that of particle-induced osteolysis?
Methods
A systematic review was performed of the PubMed and Web of Science databases. Additional relevant articles were recommended by the senior authors based on their expert opinion. Abstracts were reviewed and the manuscripts pertaining to the study questions were read in full. Studies showing support of mechanically induced osteolysis were quantified and findings summarized.
Results
We identified 49 articles of experimental design supporting the hypothesis that mechanical stimulation of peri-prosthetic bone from fluid pressure and flow can induce osteolysis. While the molecular mechanisms may overlap with those implicated in particle-induced osteolysis, mechanically induced osteolysis appears to be mediated by distinct and parallel pathways.
Conclusions
The role of mechanical stimuli is increasingly recognized in the pathogenesis of peri-prosthetic osteolysis. Current research aims to elucidate the molecular mechanisms to better target therapeutic interventions.
Title: Mechanically Induced Periprosthetic Osteolysis: A Systematic Review
Description:
Background
Peri-prosthetic bone loss can result from chemical, biological, and mechanical factors.
Mechanical stimulation via fluid pressure and flow at the bone–implant interface may be a significant cause.
Evidence supporting mechanically induced osteolysis continues to grow, but there is no synthesis of published clinical and basic science data.
Questions/Purposes
We sought to review the literature on two questions: (1) What published evidence supports the concept of mechanically induced osteolysis? (2) What is the proposed mechanism of mechanically induced osteolysis, and does it differ from that of particle-induced osteolysis?
Methods
A systematic review was performed of the PubMed and Web of Science databases.
Additional relevant articles were recommended by the senior authors based on their expert opinion.
Abstracts were reviewed and the manuscripts pertaining to the study questions were read in full.
Studies showing support of mechanically induced osteolysis were quantified and findings summarized.
Results
We identified 49 articles of experimental design supporting the hypothesis that mechanical stimulation of peri-prosthetic bone from fluid pressure and flow can induce osteolysis.
While the molecular mechanisms may overlap with those implicated in particle-induced osteolysis, mechanically induced osteolysis appears to be mediated by distinct and parallel pathways.
Conclusions
The role of mechanical stimuli is increasingly recognized in the pathogenesis of peri-prosthetic osteolysis.
Current research aims to elucidate the molecular mechanisms to better target therapeutic interventions.
Related Results
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract
The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
Do evidence summaries increase health policy‐makers' use of evidence from systematic reviews? A systematic review
Do evidence summaries increase health policy‐makers' use of evidence from systematic reviews? A systematic review
This review summarizes the evidence from six randomized controlled trials that judged the effectiveness of systematic review summaries on policymakers' decision making, or the most...
Denosumab for treating periprosthetic osteolysis: a feasibility study
Denosumab for treating periprosthetic osteolysis: a feasibility study
Abstract
Objective
Wear-induced osteolysis is a leading cause of late failure in total hip arthroplasty (THA). Denosumab, a RANKL inhibitor, supp...
Scaling of titanium implants entrains inflammation-induced osteolysis
Scaling of titanium implants entrains inflammation-induced osteolysis
AbstractWith millions of new dental and orthopedic implants inserted annually, periprosthetic osteolysis becomes a major concern. In dentistry, peri-implantitis management includes...
The molecular mechanism of Gorham syndrome: an update
The molecular mechanism of Gorham syndrome: an update
Gorham syndrome, also known as “vanishing osteopathy” and “invasive hemangiomatosis,” is a rare clinical syndrome whose etiology is unknown and can invade the whole-body skeleton. ...
Scoping review: Diagnosis and management of periprosthetic joint infection in elbow arthroplasty
Scoping review: Diagnosis and management of periprosthetic joint infection in elbow arthroplasty
Background Total elbow arthroplasty is an effective treatment for patients with painful elbow arthritis. Infection can be a serious complication. The aim of this scoping review was...
Periprosthetic Humeral Fractures in Shoulder Arthroplasty
Periprosthetic Humeral Fractures in Shoulder Arthroplasty
» The reported combined rates of intraoperative and postoperative periprosthetic humeral fractures range widely, from 1.2% to 19.4%.» The risk factors for an intraoperative humeral...
Infection in Periprosthetic Hip Fractures
Infection in Periprosthetic Hip Fractures
Fracture around the acetabulum and femur in total hip arthroplasty is a possible complication, sometimes with difficult surgical solution, namely when a sepsis is present. Peripros...