Javascript must be enabled to continue!
Effectiveness of circular external fixator in periprosthetic fractures around the knee
View through CrossRef
Abstract
Background: The incidence of periprosthetic fractures after total joint arthroplasty (TJA) is rising due to an increasing number of TJAs performed annually and the growing elderly population. In many elderly patients with periprosthetic fractures, the bone strength is lowered due to the deterioration of bone quality and a decrease in bone quantity; rigid fixation of the fracture is difficult. It is a challenging operation for orthopedic surgeons. The usefulness of circular external fixation for periprosthetic fractures has been reported in several case studies. The aim of this study was to investigate the rate of union and complications associated with circular external fixation in periprosthetic fractures around the knee. Methods: We included 19 patients with periprosthetic femur and tibial fractures who underwent osteosynthesis using a circular external fixator and had at least 2 years of follow-up. All patients had comorbidities and high risks associated with anesthesia. Tourniquets were not used in any of the patients. There were no cases in which the skin incision was placed, and the closed reduction technique was used in all cases. Results: A 100% union rate was achieved with no serious complications. All fractures healed after a mean time of 14.3±5.2 weeks (range, 8-38 weeks). The walking ability was the same level as before the injury in 13 cases. Discussion: There are many comorbidities associated with periprosthetic fractures in elderly patients. Double-plate or revision surgery were largely invasive and had high risks associated with anesthesia. Circular external fixation is a feasible and effective treatment option because it provides stable fixation, prompt postoperative mobilization, and has no major complications, especially in elderly patients who are treated for periprosthetic fractures Conclusion: Circular external fixation is a safe and reliable method for periprosthetic fractures around the knee in elderly patients. Level of evidence: Level IV, retrospective case series
Springer Science and Business Media LLC
Title: Effectiveness of circular external fixator in periprosthetic fractures around the knee
Description:
Abstract
Background: The incidence of periprosthetic fractures after total joint arthroplasty (TJA) is rising due to an increasing number of TJAs performed annually and the growing elderly population.
In many elderly patients with periprosthetic fractures, the bone strength is lowered due to the deterioration of bone quality and a decrease in bone quantity; rigid fixation of the fracture is difficult.
It is a challenging operation for orthopedic surgeons.
The usefulness of circular external fixation for periprosthetic fractures has been reported in several case studies.
The aim of this study was to investigate the rate of union and complications associated with circular external fixation in periprosthetic fractures around the knee.
Methods: We included 19 patients with periprosthetic femur and tibial fractures who underwent osteosynthesis using a circular external fixator and had at least 2 years of follow-up.
All patients had comorbidities and high risks associated with anesthesia.
Tourniquets were not used in any of the patients.
There were no cases in which the skin incision was placed, and the closed reduction technique was used in all cases.
Results: A 100% union rate was achieved with no serious complications.
All fractures healed after a mean time of 14.
3±5.
2 weeks (range, 8-38 weeks).
The walking ability was the same level as before the injury in 13 cases.
Discussion: There are many comorbidities associated with periprosthetic fractures in elderly patients.
Double-plate or revision surgery were largely invasive and had high risks associated with anesthesia.
Circular external fixation is a feasible and effective treatment option because it provides stable fixation, prompt postoperative mobilization, and has no major complications, especially in elderly patients who are treated for periprosthetic fractures Conclusion: Circular external fixation is a safe and reliable method for periprosthetic fractures around the knee in elderly patients.
Level of evidence: Level IV, retrospective case series.
Related Results
Effectiveness of circular external fixator in periprosthetic fractures around the knee
Effectiveness of circular external fixator in periprosthetic fractures around the knee
Abstract
Background: The incidence of periprosthetic fractures after total joint arthroplasty (TJA) is rising due to an increasing number of TJAs performed annually and the...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Analysis of the Effect of Ring Stiffness on the Mechanical Performance of a Two-Ring Ilizarov Fixator
Analysis of the Effect of Ring Stiffness on the Mechanical Performance of a Two-Ring Ilizarov Fixator
The two-ring Ilizarov fixator is superior, in terms of space and weight savings, to the traditional four-ring Ilizarov fixator. But the stiffness of the two-ring Ilizarov fixator i...
Risk Factors Influencing Management Outcomes of Periprosthetic Fractures Following Total Knee Arthroplasty: A Retrospective Study
Risk Factors Influencing Management Outcomes of Periprosthetic Fractures Following Total Knee Arthroplasty: A Retrospective Study
Abstract
Background
: Total knee replacement (TKR) is a widely performed surgery for advanced knee joint issues. The rising dem...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...
Periprosthetic fractures after total knee arthroplasty: review
Periprosthetic fractures after total knee arthroplasty: review
Abstract
This review of literature classifies and describes the most common periprosthetic fractures after total knee arthroplasty. Classification systems are usu...
Atypical periprosthetic femoral fracture associated with long-term bisphosphonate therapy
Atypical periprosthetic femoral fracture associated with long-term bisphosphonate therapy
Abstract
Background
Atypical femoral fracture is one of the many complications after the long-term use of bisphosphonates. The American Society for Bone and Mineral Research has of...
Sex-specific versus standard posterior cruciate-substituting total knee prosthesis
Sex-specific versus standard posterior cruciate-substituting total knee prosthesis
Background
The introduction of sex-specific (SS) knee prosthesis designs was an approach to offer more sizing options and is based on the anatomic sex differences. Thes...

