Javascript must be enabled to continue!
Effectiveness of circular external fixator in periprosthetic fractures around the knee
View through CrossRef
Abstract
Background: The incidence of periprosthetic fractures after total joint arthroplasty (TJA) is rising due to an increasing number of TJAs performed annually and the growing elderly population. In many elderly patients with periprosthetic fractures, the bone strength is lowered due to the deterioration of bone quality and a decrease in bone quantity; rigid fixation of the fracture is difficult. It is a challenging operation for orthopedic surgeons. The usefulness of circular external fixation for periprosthetic fractures has been reported in several case studies. The aim of this study was to investigate the rate of union and complications associated with circular external fixation in periprosthetic fractures around the knee. Methods: We included 19 patients with periprosthetic femur and tibial fractures who underwent osteosynthesis using a circular external fixator and had at least 2 years of follow-up. All patients had comorbidities and high risks associated with anesthesia. Tourniquets were not used in any of the patients. There were no cases in which the skin incision was placed, and the closed reduction technique was used in all cases. Results: A 100% union rate was achieved with no serious complications. All fractures healed after a mean time of 14.3±5.2 weeks (range, 8-38 weeks). The walking ability was the same level as before the injury in 13 cases. Discussion: There are many comorbidities associated with periprosthetic fractures in elderly patients. Double-plate or revision surgery were largely invasive and had high risks associated with anesthesia. Circular external fixation is a feasible and effective treatment option because it provides stable fixation, prompt postoperative mobilization, and has no major complications, especially in elderly patients who are treated for periprosthetic fractures Conclusion: Circular external fixation is a safe and reliable method for periprosthetic fractures around the knee in elderly patients. Level of evidence: Level IV, retrospective case series
Springer Science and Business Media LLC
Title: Effectiveness of circular external fixator in periprosthetic fractures around the knee
Description:
Abstract
Background: The incidence of periprosthetic fractures after total joint arthroplasty (TJA) is rising due to an increasing number of TJAs performed annually and the growing elderly population.
In many elderly patients with periprosthetic fractures, the bone strength is lowered due to the deterioration of bone quality and a decrease in bone quantity; rigid fixation of the fracture is difficult.
It is a challenging operation for orthopedic surgeons.
The usefulness of circular external fixation for periprosthetic fractures has been reported in several case studies.
The aim of this study was to investigate the rate of union and complications associated with circular external fixation in periprosthetic fractures around the knee.
Methods: We included 19 patients with periprosthetic femur and tibial fractures who underwent osteosynthesis using a circular external fixator and had at least 2 years of follow-up.
All patients had comorbidities and high risks associated with anesthesia.
Tourniquets were not used in any of the patients.
There were no cases in which the skin incision was placed, and the closed reduction technique was used in all cases.
Results: A 100% union rate was achieved with no serious complications.
All fractures healed after a mean time of 14.
3±5.
2 weeks (range, 8-38 weeks).
The walking ability was the same level as before the injury in 13 cases.
Discussion: There are many comorbidities associated with periprosthetic fractures in elderly patients.
Double-plate or revision surgery were largely invasive and had high risks associated with anesthesia.
Circular external fixation is a feasible and effective treatment option because it provides stable fixation, prompt postoperative mobilization, and has no major complications, especially in elderly patients who are treated for periprosthetic fractures Conclusion: Circular external fixation is a safe and reliable method for periprosthetic fractures around the knee in elderly patients.
Level of evidence: Level IV, retrospective case series.
Related Results
Effectiveness of circular external fixator in periprosthetic fractures around the knee
Effectiveness of circular external fixator in periprosthetic fractures around the knee
Abstract
Background: The incidence of periprosthetic fractures after total joint arthroplasty (TJA) is rising due to an increasing number of TJAs performed annually and the...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Risk Factors Influencing Management Outcomes of Periprosthetic Fractures Following Total Knee Arthroplasty: A Retrospective Study
Risk Factors Influencing Management Outcomes of Periprosthetic Fractures Following Total Knee Arthroplasty: A Retrospective Study
Abstract
Background
: Total knee replacement (TKR) is a widely performed surgery for advanced knee joint issues. The rising dem...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...
Temporarily double-pin external fixator fixation following unstable ankle fracture
Temporarily double-pin external fixator fixation following unstable ankle fracture
Abstract
This study designed a new type of double-pin external fixator for temporary fixation of unstable ankle fractures, and the safety and effectiveness of this fixation...
Management of fracture non-union long bones by limb reconstruction devices
Management of fracture non-union long bones by limb reconstruction devices
Background: The limb reconstruction system (LRS), rail road fixator, and Ilizarov fixator are used to treat open fractures with bone loss and infective non-union of long bones. It ...
Pre-Peritoneal Pelvic Pack with External Fixator Versus Pelvic Pack Alone for Hemodynamically Unstable Patients with Pelvic Fracture; A Historical Cohort Study
Pre-Peritoneal Pelvic Pack with External Fixator Versus Pelvic Pack Alone for Hemodynamically Unstable Patients with Pelvic Fracture; A Historical Cohort Study
Purpose: Pelvic fracture is one of the most common cause of death in traumatic patients. It is due to high-energy trauma and approximately 80% of patients who develop severe hemorr...
Postoperative Blood Glucose Levels Predict Infection After Total Joint Arthroplasty
Postoperative Blood Glucose Levels Predict Infection After Total Joint Arthroplasty
Background:
Perioperative hyperglycemia has many etiologies, including medication, impaired glucose tolerance, uncontrolled diabetes mellitus, or stress, the latter of ...

