Javascript must be enabled to continue!
Case Study for Bolted T-Stub Connection Design
View through CrossRef
This paper is mainly performed to investigate T-stub connection that is described on the basis of ideal strength limit states. The determination of T-stub based on the full plastic strength of the steel beam in accordance with 2005 AISC Seismic Provisions. The T-stub connections considered herein were performed to include the T-stub component of bolted moment connection frames. Therefore, the proposed T-stub models will be evaluated by comparing the required factored bar strength. T-stub components using ten high strength bolts with wider gages are demonstrated in this design. In addition, equations for connection design will be described in this paper. Finally, new design methodology is applied to T-stub connections suggested in this study.
Title: Case Study for Bolted T-Stub Connection Design
Description:
This paper is mainly performed to investigate T-stub connection that is described on the basis of ideal strength limit states.
The determination of T-stub based on the full plastic strength of the steel beam in accordance with 2005 AISC Seismic Provisions.
The T-stub connections considered herein were performed to include the T-stub component of bolted moment connection frames.
Therefore, the proposed T-stub models will be evaluated by comparing the required factored bar strength.
T-stub components using ten high strength bolts with wider gages are demonstrated in this design.
In addition, equations for connection design will be described in this paper.
Finally, new design methodology is applied to T-stub connections suggested in this study.
Related Results
Bolted Joint Simulation Techniques in Gas Turbine Components
Bolted Joint Simulation Techniques in Gas Turbine Components
Bolted joints are integral part of many industrial applications such as the most simple to the most complex and expensive machinery. They provide the primary means of connecting co...
Experimental and Numerical Study on a Novel Steel Beam-Column Connection to Short Stub Column Under Cyclic Loading
Experimental and Numerical Study on a Novel Steel Beam-Column Connection to Short Stub Column Under Cyclic Loading
This study presents the experimental and analytical evaluations on an innovative connection class under cyclic loading. The connection was an H- or I-shaped section as a short stub...
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Study of hybrid FRP-FRCM superficial structural elements
Study of hybrid FRP-FRCM superficial structural elements
(English) The
most common composite materials for strengthening building structures are divided into two
dif ferent types based on the matrix’s composition, organics (polymers) o...
Preload Monitoring in Bolted Connection Using Piezoelectric-Based Smart Interface
Preload Monitoring in Bolted Connection Using Piezoelectric-Based Smart Interface
In this study, a preload monitoring method using impedance signatures obtained from a piezoelectric-based smart interface is presented for bolted girder connections. Firstly, the b...
Thermomechanical Evaluation of the Performance and Integrity of a HDPE Stub-End Bolted Flange Connection
Thermomechanical Evaluation of the Performance and Integrity of a HDPE Stub-End Bolted Flange Connection
In this study, the integrity of a manhole structure made of a 78 in. high density polyethylene (HDPE) stub-end, steel ring, and blind flange, sealed with a compressed nonasbestos f...