Fluctuating Pressure Generating in BWR Main Steam Lines Acoustic Excited by Safety Relief Valve Stub Pipes and Dead Legs

View through CrossRef
During operation, the BWR-3 steam dryer in the Quad Cities Unit 2 Nuclear Power Plant was damaged by high cycle fatigue. The dryer failure was attributed to flow-induced acoustic resonance at the stub pipes of safety relief valves (SRVs) in the main steam lines (MSLs). The acoustic resonance was considered to be generated by interaction between the sound field and an unstable shear layer across the closed side branches with SRV stub pipes. We HITACHI and CRIEPI have started a research program on BWR dryers to develop their loading evaluation methods. Moreover, it has become necessary to evaluate the dryer integrity of BWR-5 plants in particular which are the main type of BWR in Japan. In the present study, we used 1/10-scale BWR tests and analyses to investigate the flow-induced acoustic resonance and characteristics of fluctuating pressure in MSLs. The test apparatus consisted of a steam dryer, a steam dome and 4 MSLs with 20 SRV stub pipes. A finite element method (FEM) was applied for the calculation of three-dimensional wave equations in acoustic analysis. We demonstrated that remarkable fluctuating pressures occurred in high and low frequency regions. Intensity of three peaks observed in the spectrum of fluctuating pressure in MSLs was increased with St. High frequency fluctuating pressures were generated by the flow-induced acoustic resonance in the SRV stub pipes. Low frequency fluctuating pressures were excited by the acoustic resonance in the dead leg. Frequency of fluctuating pressure generating in the SRV stub pipe was changed with St. On the other hand, frequency of fluctuating pressure excited by dead leg was almost constant. Fluctuating pressure in low frequency range increased gradually with flow velocity and its intensity was roughly proportional to the square of flow velocity. The flow-induced acoustic resonance did not occur for St larger than 0.6 in the BWR MSLs for both low and high frequency ranges. Operating conditions of the BWR-5 from 100 to 115% were in the range of St larger than 0.6, so intense acoustic resonance would not occur in the BWR MSLs.
Title: Fluctuating Pressure Generating in BWR Main Steam Lines Acoustic Excited by Safety Relief Valve Stub Pipes and Dead Legs
Description:
During operation, the BWR-3 steam dryer in the Quad Cities Unit 2 Nuclear Power Plant was damaged by high cycle fatigue.
The dryer failure was attributed to flow-induced acoustic resonance at the stub pipes of safety relief valves (SRVs) in the main steam lines (MSLs).
The acoustic resonance was considered to be generated by interaction between the sound field and an unstable shear layer across the closed side branches with SRV stub pipes.
We HITACHI and CRIEPI have started a research program on BWR dryers to develop their loading evaluation methods.
Moreover, it has become necessary to evaluate the dryer integrity of BWR-5 plants in particular which are the main type of BWR in Japan.
In the present study, we used 1/10-scale BWR tests and analyses to investigate the flow-induced acoustic resonance and characteristics of fluctuating pressure in MSLs.
The test apparatus consisted of a steam dryer, a steam dome and 4 MSLs with 20 SRV stub pipes.
A finite element method (FEM) was applied for the calculation of three-dimensional wave equations in acoustic analysis.
We demonstrated that remarkable fluctuating pressures occurred in high and low frequency regions.
Intensity of three peaks observed in the spectrum of fluctuating pressure in MSLs was increased with St.
High frequency fluctuating pressures were generated by the flow-induced acoustic resonance in the SRV stub pipes.
Low frequency fluctuating pressures were excited by the acoustic resonance in the dead leg.
Frequency of fluctuating pressure generating in the SRV stub pipe was changed with St.
On the other hand, frequency of fluctuating pressure excited by dead leg was almost constant.
Fluctuating pressure in low frequency range increased gradually with flow velocity and its intensity was roughly proportional to the square of flow velocity.
The flow-induced acoustic resonance did not occur for St larger than 0.
6 in the BWR MSLs for both low and high frequency ranges.
Operating conditions of the BWR-5 from 100 to 115% were in the range of St larger than 0.
6, so intense acoustic resonance would not occur in the BWR MSLs.

Related Results

Economic Analysis for Nozzle Governing With Overload Valve Regulation Technology
Economic Analysis for Nozzle Governing With Overload Valve Regulation Technology
With the implementation of low-carbon economy policy, clean energy (such as wind and solar energy) has been developing rapidly, and the percentage is increasing year by year; On th...
Analysis of Pressure Wave Phenomena in Steam Line Piping
Analysis of Pressure Wave Phenomena in Steam Line Piping
One challenging aspect of boiling water reactor (BWR) analysis is the ability to predict the system response following the rapid closure of a steam line control or isolation valve....
High-Pressure Saturated-Steam Correlations
High-Pressure Saturated-Steam Correlations
Summary During steam-assisted oil recovery processes, the thermal properties of saturated steam are required in the computation of heat losses and quality changes...
An Acoustically Controlled Down-Hole Safety Valve (SCSSSV)
An Acoustically Controlled Down-Hole Safety Valve (SCSSSV)
American Institute of Mining, Metallurgical, and Petroleum Engineers, Inc. Abstract A surface-controlled subsurface safety valve...
Development of Cementless Concrete Pipes Incorporating Bundled Fibers: An Alternate to Cement Concrete Pipes
Development of Cementless Concrete Pipes Incorporating Bundled Fibers: An Alternate to Cement Concrete Pipes
The use of cementless concrete (geopolymer concrete (GPC)) incorporating fly ash and bundled steel fibers to produce full-scale precast concrete pipes is an economical, viable and ...
TINBOP Cyclic Steam Injection Enhances Oil Recovery in Mature Steamfloods
TINBOP Cyclic Steam Injection Enhances Oil Recovery in Mature Steamfloods
Abstract In a previous paper (SPE/PS-CIM/CHOA 97850), we presented our findings on a novel cyclic steam injection method that we developed. The Top-Injection Bott...
STEAM DIEGIMO UGDYMO PROCESE IŠŠŪKIAI IR MOKYTOJŲ KOMPETENCIJŲ TOBULINIMO GALIMYBĖS
STEAM DIEGIMO UGDYMO PROCESE IŠŠŪKIAI IR MOKYTOJŲ KOMPETENCIJŲ TOBULINIMO GALIMYBĖS
This article investigates the opportunities for teacher competence development and the challenges that arise when implementing STEAM (Science, Technology, Engineering, Arts, and Ma...
The Hot Test of Primary Separation Equipment of Steam Generator for CAP1400 Nuclear Power Plant
The Hot Test of Primary Separation Equipment of Steam Generator for CAP1400 Nuclear Power Plant
A new type of Steam separator for CAP1400 Steam Generator is introduced. The result of characteristic experiment, the variables of which contain steam load, saturated water flow an...

Back to Top