Javascript must be enabled to continue!
Cadaveric Prehospital Amputation: Which Reciprocating Saw Blade Offers the Most Efficient Amputation
View through CrossRef
AbstractObjective:Field amputations are a low-frequency, high-risk procedure. Many prehospital personnel utilize the reciprocating saw. This study compares the efficiency, speed, and degree of tissue damage of different reciprocating saw blades found commercially.Methods:Amputations were performed on two human cadavers at different levels of the upper and lower extremities. Four different blades were used, each with a different teeth-per-inch (TPI) design. The amputations were timed, blade temperature was recorded, subjective operator effort was obtained, amount of splatter was evaluated, and an orthopedic physician evaluated the extent of tissue damage and operating room repair difficulty.Results:The blade with fourteen TPI was superior in overall speed to complete the amputations at 1.07 seconds per one centimeter of tissue (SD = 0.49 seconds) and had the lowest fail rate (0/8 amputations). The three TPI, six TPI, and ten TPI blades all required a “rescue” technique and were slower. The blade with fourteen TPI caused the least amount of tissue damage and was deemed the easiest to repair. Secondary outcomes demonstrated the fourteen TPI blade had generated the least amount of heat and produced the least amount of splatter. All blades had a perceived effort of “easy” to complete the amputation.Conclusion:While all blades were able to achieve an amputation, the overall recommendation is use of a fourteen TPI blade. It did not require any rescue techniques, provided the most straightforward amputation to repair, had the least amount of biohazard splatter and temperature increase, and was the fastest blade overall.
Cambridge University Press (CUP)
Title: Cadaveric Prehospital Amputation: Which Reciprocating Saw Blade Offers the Most Efficient Amputation
Description:
AbstractObjective:Field amputations are a low-frequency, high-risk procedure.
Many prehospital personnel utilize the reciprocating saw.
This study compares the efficiency, speed, and degree of tissue damage of different reciprocating saw blades found commercially.
Methods:Amputations were performed on two human cadavers at different levels of the upper and lower extremities.
Four different blades were used, each with a different teeth-per-inch (TPI) design.
The amputations were timed, blade temperature was recorded, subjective operator effort was obtained, amount of splatter was evaluated, and an orthopedic physician evaluated the extent of tissue damage and operating room repair difficulty.
Results:The blade with fourteen TPI was superior in overall speed to complete the amputations at 1.
07 seconds per one centimeter of tissue (SD = 0.
49 seconds) and had the lowest fail rate (0/8 amputations).
The three TPI, six TPI, and ten TPI blades all required a “rescue” technique and were slower.
The blade with fourteen TPI caused the least amount of tissue damage and was deemed the easiest to repair.
Secondary outcomes demonstrated the fourteen TPI blade had generated the least amount of heat and produced the least amount of splatter.
All blades had a perceived effort of “easy” to complete the amputation.
Conclusion:While all blades were able to achieve an amputation, the overall recommendation is use of a fourteen TPI blade.
It did not require any rescue techniques, provided the most straightforward amputation to repair, had the least amount of biohazard splatter and temperature increase, and was the fastest blade overall.
Related Results
Barriers to access prehospital care in Jimma City, Oromiya Region of Ethiopia
Barriers to access prehospital care in Jimma City, Oromiya Region of Ethiopia
Background: African nations experience a significant proportion of the global burden of death and disability. The provision of prehospital emergency care has been shown to partiall...
Discrete element parameter calibration and wear characteristics analysis of soil-rotary tillage blade in gneiss mountainous area
Discrete element parameter calibration and wear characteristics analysis of soil-rotary tillage blade in gneiss mountainous area
Abstract
Aiming at the problems of fast wear and short service life of rotary tillage blade in gneiss mountainous area, and the lack of accurate and reliable discrete eleme...
Neurological outcomes in children dead on hospital arrival
Neurological outcomes in children dead on hospital arrival
Abstract
Introduction
Obtaining favorable neurological outcomes is extremely difficult in children transported to a hospital without a prehospital r...
Influence of Tailored Boundary Layer Suction on Aerodynamic Performance in Bowed Compressor Cascades
Influence of Tailored Boundary Layer Suction on Aerodynamic Performance in Bowed Compressor Cascades
The impact of boundary layer suction on the aerodynamic performance of bowed compressor cascades is discussed in this paper. Preliminary studies are conducted in the context of a h...
Disentangling blade and vasculature shape in grapevine leaves
Disentangling blade and vasculature shape in grapevine leaves
Abstract
The leaf blade and vasculature develop together within a shared morphological space. Despite shared molecular patterning pathways, it is unknown if develop...
Approximation of the Profile of Gas Turbine Engine Blades
Approximation of the Profile of Gas Turbine Engine Blades
Introduction. Increasing the durability of gas turbine engine (GTE) blades is achieved through the use of special protective coatings on their surface. For the development of such ...
Investigation on aerodynamic interference mechanism of a contra-rotating propfan under take-off condition
Investigation on aerodynamic interference mechanism of a contra-rotating propfan under take-off condition
Abstract
Contra-rotating propfan (CRP) produce significant aerodynamic interference between the front and rear blades. The interaction effect of the front blade o...
PP33 Use of point of care ultrasound in prehospital care: an interview study
PP33 Use of point of care ultrasound in prehospital care: an interview study
BackgroundPoint of Care Ultrasound (PoCUS) is a currently available and rapidly developing technology but still not widely used in the UK. Prehospital PoCUS could help to prioritis...

