Javascript must be enabled to continue!
Dosimetry for nonuniform activity distributions: A method for the calculation of 3D absorbed‐dose distribution without the use of voxel S‐values, point kernels, or Monte Carlo simulations
View through CrossRef
Purpose:Nonuniform activity within the target lesions and the critical organs constitutes an important limitation for dosimetric estimates in patients treated with tumor‐seeking radiopharmaceuticals. The tumor control probability and the normal tissue complication probability are affected by the distribution of the radionuclide in the treated organ/tissue. In this paper, a straightforward method for calculating the absorbed dose at the voxel level is described. This new method takes into account a nonuniform activity distribution in the target/organ.Methods:The new method is based on the macroscopicS‐values (i.e., the S‐values calculated for the various organs, as defined in the MIRD approach), on the definition of the number of voxels, and on the raw‐count 3D array, corrected for attenuation, scatter, and collimator resolution, in the lesion/organ considered. Starting from these parameters, the only mathematical operation required is to multiply the 3D array by a scalar value, thus avoiding all the complex operations involving the 3D arrays.Results:A comparison with the MIRD approach, fully described in the MIRD Pamphlet No. 17, usingS‐values at the voxel level, showed a good agreement between the two methods for 131I and for 90Y.Conclusions:Voxel dosimetry is becoming more and more important when performing therapy with tumor‐seeking radiopharmaceuticals. The method presented here does not require calculating theS‐values at the voxel level, and thus bypasses the mathematical problems linked to the convolution of 3D arrays and to the voxel size. In the paper, the results obtained with this new simplified method as well as the possibility of using it for other radionuclides commonly employed in therapy are discussed. The possibility of using the correct density value of the tissue/organs involved is also discussed.
Title: Dosimetry for nonuniform activity distributions: A method for the calculation of 3D absorbed‐dose distribution without the use of voxel S‐values, point kernels, or Monte Carlo simulations
Description:
Purpose:Nonuniform activity within the target lesions and the critical organs constitutes an important limitation for dosimetric estimates in patients treated with tumor‐seeking radiopharmaceuticals.
The tumor control probability and the normal tissue complication probability are affected by the distribution of the radionuclide in the treated organ/tissue.
In this paper, a straightforward method for calculating the absorbed dose at the voxel level is described.
This new method takes into account a nonuniform activity distribution in the target/organ.
Methods:The new method is based on the macroscopicS‐values (i.
e.
, the S‐values calculated for the various organs, as defined in the MIRD approach), on the definition of the number of voxels, and on the raw‐count 3D array, corrected for attenuation, scatter, and collimator resolution, in the lesion/organ considered.
Starting from these parameters, the only mathematical operation required is to multiply the 3D array by a scalar value, thus avoiding all the complex operations involving the 3D arrays.
Results:A comparison with the MIRD approach, fully described in the MIRD Pamphlet No.
17, usingS‐values at the voxel level, showed a good agreement between the two methods for 131I and for 90Y.
Conclusions:Voxel dosimetry is becoming more and more important when performing therapy with tumor‐seeking radiopharmaceuticals.
The method presented here does not require calculating theS‐values at the voxel level, and thus bypasses the mathematical problems linked to the convolution of 3D arrays and to the voxel size.
In the paper, the results obtained with this new simplified method as well as the possibility of using it for other radionuclides commonly employed in therapy are discussed.
The possibility of using the correct density value of the tissue/organs involved is also discussed.
Related Results
Updates on SPICE for ESA Missions
Updates on SPICE for ESA Missions
Introduction:  SPICE is an information system the purpose of which is to provide scientists the observation geometry needed to plan scientific observations and to analyze ...
REGULAR ARTICLES
REGULAR ARTICLES
L. Cowen and
C. J.
Schwarz
657Les Radio‐tags, en raison de leur détectabilitéélevée, ...
Updates on SPICE for ESA Missions
Updates on SPICE for ESA Missions
Introduction: SPICE is an information system the purpose of which is to provide scientists the observation geometry needed to plan scientific observations and to analyze the data r...
Tumor dosimetry in radioimmunotherapy: Methods of calculation for beta particles
Tumor dosimetry in radioimmunotherapy: Methods of calculation for beta particles
Calculational methods of beta‐particle dosimetry in radioimmunotherapy (RIT) are reviewed for clinical and experimental studies and computer modeling of tumors. In clinical studies...
Monte Carlo methods: barrier option pricing with stable Greeks and multilevel Monte Carlo learning
Monte Carlo methods: barrier option pricing with stable Greeks and multilevel Monte Carlo learning
For discretely observed barrier options, there exists no closed solution under the Black-Scholes model. Thus, it is often helpful to use Monte Carlo simulations, which are easily a...
On the use of the absorbed depth‐dose measurements in the beam calibration of a surface electronic high‐dose‐rate brachytherapy unit, a Monte Carlo‐based study
On the use of the absorbed depth‐dose measurements in the beam calibration of a surface electronic high‐dose‐rate brachytherapy unit, a Monte Carlo‐based study
PurposeTo evaluate the use of the absorbed depth‐dose as a surrogate of the half‐value layer in the calibration of a high‐dose‐rate electronic brachytherapy (eBT) equipment. The ef...
Automation of the Monte Carlo simulation of medical linear accelerators
Automation of the Monte Carlo simulation of medical linear accelerators
The main result of this thesis is a software system, called PRIMO, which simulates clinical linear accelerators and the subsequent dose distributions using the Monte Carlo method. ...
SU‐GG‐T‐393: Optimization Platform Based on Monte Carlo Dose Calculation
SU‐GG‐T‐393: Optimization Platform Based on Monte Carlo Dose Calculation
Purpose: Dosimetry and planning for brachytherapy relies on the TG43 formula. This formalism, like any homogeneous dose calculation method, neglects the various effect of heterogen...

