Optimal Operational Planning of Cogeneration Systems With Microturbine and Desiccant Air-Conditioning Units
View through CrossRef
Economic and energy-saving characteristics of cogeneration systems with microturbine and desiccant air-conditioning units are investigated on system operational planning. An optimization approach is adopted to rationally evaluate these characteristics. In this approach, on/off and rated/part load status of operation of equipment and energy flow rates are determined so as to minimize the hourly energy charge subject to satisfaction of energy demand requirements. In this optimization problem, performance characteristics of the microturbine and desiccant air-conditioning units are modeled in consideration of the influence due to ambient air temperature. Moreover, the influence due to ambient air humidity is also considered in the desiccant air-conditioning unit using the psychrometric diagram. The implementation of the numerical analysis method, discussed in this paper, to two cogeneration systems, clearly shows economic and operational benefits of using desiccant air-conditioning.
Title: Optimal Operational Planning of Cogeneration Systems With Microturbine and Desiccant Air-Conditioning Units
Description:
Economic and energy-saving characteristics of cogeneration systems with microturbine and desiccant air-conditioning units are investigated on system operational planning.
An optimization approach is adopted to rationally evaluate these characteristics.
In this approach, on/off and rated/part load status of operation of equipment and energy flow rates are determined so as to minimize the hourly energy charge subject to satisfaction of energy demand requirements.
In this optimization problem, performance characteristics of the microturbine and desiccant air-conditioning units are modeled in consideration of the influence due to ambient air temperature.
Moreover, the influence due to ambient air humidity is also considered in the desiccant air-conditioning unit using the psychrometric diagram.
The implementation of the numerical analysis method, discussed in this paper, to two cogeneration systems, clearly shows economic and operational benefits of using desiccant air-conditioning.
Related Results
Adsorption Cooling With Multi-Stage Desiccant Processes
Adsorption Cooling With Multi-Stage Desiccant Processes
For traditional adsorption cooling systems using silica-gel-like desiccant wheels, the moisture is removed from the air and stored in the desiccant wheels. The subsequent reactivat...
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Exposure to volatile organic compounds (VOC) in workplaces can cause acute effects such as irritation of the skin, the eyes, the mouth, and the nose. Some products may also cause c...
Parametric Study on Economic Feasibility of Microturbine Cogeneration Systems by an Optimization Approach
Parametric Study on Economic Feasibility of Microturbine Cogeneration Systems by an Optimization Approach
Economic feasibility of microturbine cogeneration systems is investigated by analyzing relationships between the optimal number of microturbine units and the maximum energy demands...
Parametric Study on Economic Feasibility of Microturbine Cogeneration Systems by an Optimization Approach
Parametric Study on Economic Feasibility of Microturbine Cogeneration Systems by an Optimization Approach
Economic feasibility of microturbine cogeneration systems is investigated by analyzing relationships between the optimal number of microturbine units and the maximum energy demands...
Analysis of Optimal Unit Numbers and Sizes for Microturbine Cogeneration Systems
Analysis of Optimal Unit Numbers and Sizes for Microturbine Cogeneration Systems
The relationships between unit numbers and capacities to be installed for microturbine cogeneration systems are analyzed from an economic viewpoint. In analyzing, an optimization a...
Combining desiccant dehumidification with Hot Air and Microwave food drying: a sustainable and economical method to produce dried snacks
Combining desiccant dehumidification with Hot Air and Microwave food drying: a sustainable and economical method to produce dried snacks
Abstract
Solar hot air drying is a food dehydration method that is quickly gaining traction in South Asia due to its very low capital and operational cost. The long drying ...
EFEKTIFITAS JENIS DESIKAN DAN KECEPATAN UDARA TERHADAP PENYERAPAN UAP AIR DI UDARA
EFEKTIFITAS JENIS DESIKAN DAN KECEPATAN UDARA TERHADAP PENYERAPAN UAP AIR DI UDARA
Dry air is widely used in many fields, but the excessive water vapor in the air will make some problem and should be minimized to get the required dry air. The purpose of th...
Thermodynamic Analysis of Irreversible Desiccant Systems
Thermodynamic Analysis of Irreversible Desiccant Systems
A new general thermodynamic mapping of desiccant systems’ performance is conducted to estimate the potentiality and determine the proper application field of the technology. This t...