Javascript must be enabled to continue!
Experimental Analysis of Solar Assisted Liquid Desiccant Cooling System
View through CrossRef
Dehumidifier is that the most vital unit in liquid drier air conditioning system, this paper experimental analysis of solar assisted liquid desiccant cooling system (SALDCS) by Li Cl-H2O as a desiccant. A capable solar energy and cooling technique is through the employment of a liquid drying agent system, wherever humidness is absorbed directly from the method air by direct contact with the drying agent, the desiccant is then regenerated by solar hot water or air. The solar assisted desiccant dehumidifier system is operated variable operating conditions, air flow rate (0.05 to 0.11 kg/sec), desiccant concentration (30% to 40%) and desiccant temperature (maximum 40oC). Effectiveness of dehumidifier verified by experimentally, it results effectiveness decreased by the air flow rate & desiccant temperature, increased by desiccant concentration, the same process done with inter cooler (Indirect evaporative cooler) better dry-air cooling rate observed.
Title: Experimental Analysis of Solar Assisted Liquid Desiccant Cooling System
Description:
Dehumidifier is that the most vital unit in liquid drier air conditioning system, this paper experimental analysis of solar assisted liquid desiccant cooling system (SALDCS) by Li Cl-H2O as a desiccant.
A capable solar energy and cooling technique is through the employment of a liquid drying agent system, wherever humidness is absorbed directly from the method air by direct contact with the drying agent, the desiccant is then regenerated by solar hot water or air.
The solar assisted desiccant dehumidifier system is operated variable operating conditions, air flow rate (0.
05 to 0.
11 kg/sec), desiccant concentration (30% to 40%) and desiccant temperature (maximum 40oC).
Effectiveness of dehumidifier verified by experimentally, it results effectiveness decreased by the air flow rate & desiccant temperature, increased by desiccant concentration, the same process done with inter cooler (Indirect evaporative cooler) better dry-air cooling rate observed.
Related Results
Adsorption Cooling With Multi-Stage Desiccant Processes
Adsorption Cooling With Multi-Stage Desiccant Processes
For traditional adsorption cooling systems using silica-gel-like desiccant wheels, the moisture is removed from the air and stored in the desiccant wheels. The subsequent reactivat...
Multilayered artificial neural network for performance prediction of an adiabatic solar liquid desiccant dehumidifier
Multilayered artificial neural network for performance prediction of an adiabatic solar liquid desiccant dehumidifier
Abstract
In this study, a multi-layered artificial neural network (ANN) algorithm was developed and trained to predict the performance of a solar powered liquid desi...
Solar Trackers Using Six-Bar Linkages
Solar Trackers Using Six-Bar Linkages
Abstract
A solar panel faces the sun or has the solar ray normal to its face to enhance power reaping. A fixed solar panel can only meet this condition at one moment...
Combining desiccant dehumidification with Hot Air and Microwave food drying: a sustainable and economical method to produce dried snacks
Combining desiccant dehumidification with Hot Air and Microwave food drying: a sustainable and economical method to produce dried snacks
Abstract
Solar hot air drying is a food dehydration method that is quickly gaining traction in South Asia due to its very low capital and operational cost. The long drying ...
Selective Head Cooling in Newborn Infants After Perinatal Asphyxia: A Safety Study
Selective Head Cooling in Newborn Infants After Perinatal Asphyxia: A Safety Study
Aims.To determine the practicality and safety of head cooling with mild or minimal systemic hypothermia in term neonates with moderate to severe hypoxic-ischemic encephalopathy.Met...
Investigation of dehumidifier performance parameters using ANN-PSO algorithm
Investigation of dehumidifier performance parameters using ANN-PSO algorithm
ABSTRACT In this investigation, a performance analysis of a liquid desiccant-based dehumidification system was conducted by integrating a particle swarm optimization (PSO) algorith...
Simulation Study of Desiccant Dehumidifier: A Review
Simulation Study of Desiccant Dehumidifier: A Review
Traditional cooling systems based on vapor compression are ineffective in humid climates due to their inability to remove moisture below the dew point of the conditioned air, which...
Solar wind interaction with comet 67P around perihelion
Solar wind interaction with comet 67P around perihelion
AbstractNear perihelion, when comet 67P was most active, the Rosetta spacecraft resided inside the comet induced magnetosphere. The solar wind magnetic field was still present, but...

